- ICH GCP
- Registro de ensaios clínicos dos EUA
- Ensaio Clínico NCT06077396
A canulação da artéria radial afeta o índice de perfusão (IP) da mão em operações de transplante de fígado? (radial artery)
A canulação da artéria radial afeta o índice de perfusão da mão no transplante de fígado?
This randomized controlled trial compared palpation-guided and ultrasound-guided radial artery catheterization in adult liver transplant recipients. The primary outcome was the change in perfusion index (Pi) from baseline after catheterization. Secondary outcomes included first-attempt success, number of skin punctures, procedure time, overall success with the assigned technique, and local complications.
Visão geral do estudo
Status
Intervenção / Tratamento
Descrição detalhada
## DLiver transplantation is associated with major hemodynamic changes, and continuous invasive arterial pressure monitoring is an essential part of perioperative management. The radial artery is the most commonly used site. Repeated punctures and mechanical trauma during catheterization may cause local complications and affect peripheral perfusion. Ultrasound guidance may facilitate catheter placement with fewer punctures.
The perfusion index (Pi), derived from pulse oximetry, is the ratio of the pulsatile to the non-pulsatile optical signal and is used to monitor peripheral perfusion. Because Pi is also influenced by systemic hemodynamics, sympathetic activity, temperature, nociception and drugs, changes in Pi were not interpreted as direct evidence of radial artery vasospasm.
In this prospective, randomized, controlled, two-arm parallel-group trial, adult liver transplant recipients were randomized 1:1 to palpation-guided or ultrasound-guided radial artery catheterization. Randomization used a computer-generated sequence and sequentially numbered, opaque, sealed envelopes prepared by an independent person. The envelope was opened after induction of general anesthesia, once hemodynamic stability was achieved and immediately before catheterization. All procedures were performed by a single anesthesiologist experienced in both techniques, using the same 20-gauge non-guidewire arterial cannula in both groups, preferably on the non-dominant hand after a normal modified Allen test.
In the ultrasound group, a high-frequency linear probe was used with a short-axis out-of-plane approach and dynamic needle tip positioning. Pi was measured continuously with a pulse oximetry sensor placed on the index finger the hand. Pi, heart rate, SpO2, pleth variability index (PVI), SpHb and SpOC were recorded immediately before catheterization (baseline) and immediately after catheterization; Pi was additionally recorded 5 and 10 minutes after catheterization.
The primary outcome was the change in Pi from baseline over time. The primary analysis used a linear mixed-effects model including group, time and the group-by-time interaction to account for repeated measurements. Secondary outcomes were compared with appropriate tests (t test or Mann-Whitney U test; chi-square or Fisher's exact test). Results were reported with effect estimates and 95% confidence intervals; a two-sided p<0.05 was considered statistically significant.
Tipo de estudo
Inscrição (Estimado)
Estágio
- Não aplicável
Contactos e Locais
Contato de estudo
- Nome: duygu demiroz
- Número de telefone: 905319504421
- E-mail: drduygudemiroz@hotmail.com
Critérios de participação
Critérios de elegibilidade
Idades elegíveis para estudo
Aceita Voluntários Saudáveis
Gêneros Elegíveis para o Estudo
Descrição
Inclusion Criteria:
- Adult patients (18 years of age or older) undergoing liver transplantation.
- Patients eligible for radial artery catheterization as part of perioperative monitoring.
- Patients who provide informed consent to participate in the study.
Exclusion Criteria:
- Patients in whom radial artery catheterization is contraindicated.
- Patients who do not provide informed consent to participate in the study.
Plano de estudo
Como o estudo é projetado?
Detalhes do projeto
- Finalidade Principal: Tratamento
- Alocação: Randomizado
- Modelo Intervencional: Atribuição Paralela
- Mascaramento: Nenhum (rótulo aberto)
Armas e Intervenções
Grupo de Participantes / Braço |
Intervenção / Tratamento |
|---|---|
|
Outro: Conventional Palpation
Conventional Palpation |
Radial artery catheterization was performed after induction of general anesthesia, preferably on the non-dominant hand after a normal modified Allen test. The radial pulse was identified by palpation and the artery was cannulated using anatomical landmarks with a 20-gauge non-guidewire arterial cannula, the same cannula used in the ultrasound group. The procedure was limited to a maximum of three skin punctures. |
|
Outro: Guided Catheterization
-Radial artery catheterization was performed after induction of general anesthesia using the conventional palpation technique. The radial pulse was identified by palpation and the artery was cannulated using anatomical landmarks with a 20-gauge non-guidewire arterial cannula, limited to a maximum of three skin punctures. |
Radial artery catheterization performed under real-time ultrasound guidance using an integrated guidewire arterial cannula system. |
O que o estudo está medindo?
Medidas de resultados primários
Medida de resultado |
Descrição da medida |
Prazo |
|---|---|---|
|
Change in Perfusion Index from Baseline Following Radial Artery Catheterization
Prazo: Perfusion index (Pi) will be measured at baseline, immediately after radial artery catheterization, and at 5 and 10 minutes after the procedure to evaluate changes in peripheral perfusion.
|
Perfusion index (Pi) will be measured at baseline, immediately after radial artery catheterization, and at 5 and 10 minutes after the procedure to assess changes in peripheral perfusion between the palpation-guided and ultrasound-guided catheterization groups. |
Perfusion index (Pi) will be measured at baseline, immediately after radial artery catheterization, and at 5 and 10 minutes after the procedure to evaluate changes in peripheral perfusion.
|
Medidas de resultados secundários
Medida de resultado |
Descrição da medida |
Prazo |
|---|---|---|
|
First-Attempt Radial Artery Catheterization Success Rate
Prazo: During the catheterization procedure
|
The proportion of participants in whom radial artery catheterization is successfully completed on the first skin puncture. |
During the catheterization procedure
|
Colaboradores e Investigadores
Patrocinador
Investigadores
- Investigador principal: duygu demiröz, INONU UNİVERSİTY
Publicações e links úteis
Publicações Gerais
- Brzezinski M, Luisetti T, London MJ. Radial artery cannulation: a comprehensive review of recent anatomic and physiologic investigations. Anesth Analg. 2009 Dec;109(6):1763-81. doi: 10.1213/ANE.0b013e3181bbd416.
- Numaguchi A, Adachi YU, Aoki Y, Ishii Y, Suzuki K, Obata Y, Sato S, Nishiwaki K, Matsuda N. Radial artery cannulation decreases the distal arterial blood flow measured by power Doppler ultrasound. J Clin Monit Comput. 2015 Oct;29(5):653-7. doi: 10.1007/s10877-014-9648-5. Epub 2014 Dec 16.
Datas de registro do estudo
Datas Principais do Estudo
Início do estudo (Estimado)
Conclusão Primária (Estimado)
Conclusão do estudo (Estimado)
Datas de inscrição no estudo
Enviado pela primeira vez
Enviado pela primeira vez que atendeu aos critérios de CQ
Primeira postagem (Real)
Atualizações de registro de estudo
Última Atualização Postada (Real)
Última atualização enviada que atendeu aos critérios de controle de qualidade
Última verificação
Mais Informações
Termos relacionados a este estudo
Palavras-chave
Outros números de identificação do estudo
- INU-LT-RAC-2026-01
Plano para dados de participantes individuais (IPD)
Planeja compartilhar dados de participantes individuais (IPD)?
Informações sobre medicamentos e dispositivos, documentos de estudo
Estuda um medicamento regulamentado pela FDA dos EUA
Estuda um produto de dispositivo regulamentado pela FDA dos EUA
Essas informações foram obtidas diretamente do site clinicaltrials.gov sem nenhuma alteração. Se você tiver alguma solicitação para alterar, remover ou atualizar os detalhes do seu estudo, entre em contato com register@clinicaltrials.gov. Assim que uma alteração for implementada em clinicaltrials.gov, ela também será atualizada automaticamente em nosso site .