Beeinflusst die Kanülierung der Arteria radialis den Perfusionsindex (PI) der Hand bei Lebertransplantationen? (radial artery)
Beeinflusst die Kanülierung der Arteria radialis den Perfusionsindex der Hand bei einer Lebertransplantation?
This randomized controlled trial compared palpation-guided and ultrasound-guided radial artery catheterization in adult liver transplant recipients. The primary outcome was the change in perfusion index (Pi) from baseline after catheterization. Secondary outcomes included first-attempt success, number of skin punctures, procedure time, overall success with the assigned technique, and local complications.
Studienübersicht
Status
Intervention / Behandlung
Detaillierte Beschreibung
## DLiver transplantation is associated with major hemodynamic changes, and continuous invasive arterial pressure monitoring is an essential part of perioperative management. The radial artery is the most commonly used site. Repeated punctures and mechanical trauma during catheterization may cause local complications and affect peripheral perfusion. Ultrasound guidance may facilitate catheter placement with fewer punctures.
The perfusion index (Pi), derived from pulse oximetry, is the ratio of the pulsatile to the non-pulsatile optical signal and is used to monitor peripheral perfusion. Because Pi is also influenced by systemic hemodynamics, sympathetic activity, temperature, nociception and drugs, changes in Pi were not interpreted as direct evidence of radial artery vasospasm.
In this prospective, randomized, controlled, two-arm parallel-group trial, adult liver transplant recipients were randomized 1:1 to palpation-guided or ultrasound-guided radial artery catheterization. Randomization used a computer-generated sequence and sequentially numbered, opaque, sealed envelopes prepared by an independent person. The envelope was opened after induction of general anesthesia, once hemodynamic stability was achieved and immediately before catheterization. All procedures were performed by a single anesthesiologist experienced in both techniques, using the same 20-gauge non-guidewire arterial cannula in both groups, preferably on the non-dominant hand after a normal modified Allen test.
In the ultrasound group, a high-frequency linear probe was used with a short-axis out-of-plane approach and dynamic needle tip positioning. Pi was measured continuously with a pulse oximetry sensor placed on the index finger the hand. Pi, heart rate, SpO2, pleth variability index (PVI), SpHb and SpOC were recorded immediately before catheterization (baseline) and immediately after catheterization; Pi was additionally recorded 5 and 10 minutes after catheterization.
The primary outcome was the change in Pi from baseline over time. The primary analysis used a linear mixed-effects model including group, time and the group-by-time interaction to account for repeated measurements. Secondary outcomes were compared with appropriate tests (t test or Mann-Whitney U test; chi-square or Fisher's exact test). Results were reported with effect estimates and 95% confidence intervals; a two-sided p<0.05 was considered statistically significant.
Studientyp
Einschreibung (Geschätzt)
Phase
- Unzutreffend
Kontakte und Standorte
Studienkontakt
- Name: duygu demiroz
- Telefonnummer: 905319504421
- E-Mail: drduygudemiroz@hotmail.com
Teilnahmekriterien
Zulassungskriterien
Studienberechtigtes Alter
Akzeptiert gesunde Freiwillige
Studienberechtigte Geschlechter
Beschreibung
Inclusion Criteria:
- Adult patients (18 years of age or older) undergoing liver transplantation.
- Patients eligible for radial artery catheterization as part of perioperative monitoring.
- Patients who provide informed consent to participate in the study.
Exclusion Criteria:
- Patients in whom radial artery catheterization is contraindicated.
- Patients who do not provide informed consent to participate in the study.
Studienplan
Wie ist die Studie aufgebaut?
Designdetails
- Hauptzweck: Behandlung
- Zuteilung: Zufällig
- Interventionsmodell: Parallele Zuordnung
- Maskierung: Keine (Offenes Etikett)
Waffen und Interventionen
Teilnehmergruppe / Arm |
Intervention / Behandlung |
|---|---|
|
Sonstiges: Conventional Palpation
Conventional Palpation |
Radial artery catheterization was performed after induction of general anesthesia, preferably on the non-dominant hand after a normal modified Allen test. The radial pulse was identified by palpation and the artery was cannulated using anatomical landmarks with a 20-gauge non-guidewire arterial cannula, the same cannula used in the ultrasound group. The procedure was limited to a maximum of three skin punctures. |
|
Sonstiges: Guided Catheterization
-Radial artery catheterization was performed after induction of general anesthesia using the conventional palpation technique. The radial pulse was identified by palpation and the artery was cannulated using anatomical landmarks with a 20-gauge non-guidewire arterial cannula, limited to a maximum of three skin punctures. |
Radial artery catheterization performed under real-time ultrasound guidance using an integrated guidewire arterial cannula system. |
Was misst die Studie?
Primäre Ergebnismessungen
Ergebnis Maßnahme |
Maßnahmenbeschreibung |
Zeitfenster |
|---|---|---|
|
Change in Perfusion Index from Baseline Following Radial Artery Catheterization
Zeitfenster: Perfusion index (Pi) will be measured at baseline, immediately after radial artery catheterization, and at 5 and 10 minutes after the procedure to evaluate changes in peripheral perfusion.
|
Perfusion index (Pi) will be measured at baseline, immediately after radial artery catheterization, and at 5 and 10 minutes after the procedure to assess changes in peripheral perfusion between the palpation-guided and ultrasound-guided catheterization groups. |
Perfusion index (Pi) will be measured at baseline, immediately after radial artery catheterization, and at 5 and 10 minutes after the procedure to evaluate changes in peripheral perfusion.
|
Sekundäre Ergebnismessungen
Ergebnis Maßnahme |
Maßnahmenbeschreibung |
Zeitfenster |
|---|---|---|
|
First-Attempt Radial Artery Catheterization Success Rate
Zeitfenster: During the catheterization procedure
|
The proportion of participants in whom radial artery catheterization is successfully completed on the first skin puncture. |
During the catheterization procedure
|
Mitarbeiter und Ermittler
Sponsor
Ermittler
- Hauptermittler: duygu demiröz, INONU UNİVERSİTY
Publikationen und hilfreiche Links
Allgemeine Veröffentlichungen
- Brzezinski M, Luisetti T, London MJ. Radial artery cannulation: a comprehensive review of recent anatomic and physiologic investigations. Anesth Analg. 2009 Dec;109(6):1763-81. doi: 10.1213/ANE.0b013e3181bbd416.
- Numaguchi A, Adachi YU, Aoki Y, Ishii Y, Suzuki K, Obata Y, Sato S, Nishiwaki K, Matsuda N. Radial artery cannulation decreases the distal arterial blood flow measured by power Doppler ultrasound. J Clin Monit Comput. 2015 Oct;29(5):653-7. doi: 10.1007/s10877-014-9648-5. Epub 2014 Dec 16.
Studienaufzeichnungsdaten
Haupttermine studieren
Studienbeginn (Geschätzt)
Primärer Abschluss (Geschätzt)
Studienabschluss (Geschätzt)
Studienanmeldedaten
Zuerst eingereicht
Zuerst eingereicht, das die QC-Kriterien erfüllt hat
Zuerst gepostet (Tatsächlich)
Studienaufzeichnungsaktualisierungen
Letztes Update gepostet (Tatsächlich)
Letztes eingereichtes Update, das die QC-Kriterien erfüllt
Zuletzt verifiziert
Mehr Informationen
Begriffe im Zusammenhang mit dieser Studie
Schlüsselwörter
Andere Studien-ID-Nummern
- INU-LT-RAC-2026-01
Plan für individuelle Teilnehmerdaten (IPD)
Planen Sie, individuelle Teilnehmerdaten (IPD) zu teilen?
Arzneimittel- und Geräteinformationen, Studienunterlagen
Studiert ein von der US-amerikanischen FDA reguliertes Arzneimittelprodukt
Studiert ein von der US-amerikanischen FDA reguliertes Geräteprodukt
Diese Informationen wurden ohne Änderungen direkt von der Website clinicaltrials.gov abgerufen. Wenn Sie Ihre Studiendaten ändern, entfernen oder aktualisieren möchten, wenden Sie sich bitte an register@clinicaltrials.gov. Sobald eine Änderung auf clinicaltrials.gov implementiert wird, wird diese automatisch auch auf unserer Website aktualisiert .