- ICH GCP
- Yhdysvaltain kliinisten tutkimusten rekisteri
- Kliininen tutkimus NCT07760974
Evaluation the Accuracy of Immediate Implant Placement Using SocketFit Static Surgical Guide Versus Conventional Static Surgical Guide in Anterior Esthetic Zone (SocketFit)
tiistai 11. elokuuta 2026 päivittänyt: Aliaa Saeed Kishk, Tanta University
This study compares two types of surgical guides used during immediate dental implant placement in the upper front teeth.
One guide is a conventional static surgical guide, while the other is a modified SocketFit static surgical guide designed to improve stability after tooth extraction.
The purpose of the study is to determine whether the SocketFit guide improves the accuracy of implant placement.The findings may help improve the precision and predictability of immediate dental implant treatment in the anterior esthetic zone.
Tutkimuksen yleiskatsaus
Tila
Rekrytointi
Interventio / Hoito
Yksityiskohtainen kuvaus
Immediate implant placement in the anterior esthetic zone is a predictable treatment option that reduces treatment time and preserves peri-implant soft and hard tissues.
Static computer-guided surgery has improved the accuracy of implant placement; however, guide stability may be compromised immediately after tooth extraction because of complex morphology and angulation of post-extraction sockets, as well as variations in bone density.These factors can lead to surgical drill displacement, causing the implant to deviate from its intended trajectory.Therefore, The SocketFit static surgical guide incorporates a socket-engaging extension designed to enhance guide seating and stability during osteotomy preparation.
Limited evidence is available regarding the accuracy of this modified guide compared with the conventional tooth-supported static surgical guide.
Therefore, this study aims to evaluate the accuracy of immediate implant placement using the SocketFit static surgical guide versus the conventional static surgical guide in the anterior esthetic zone.
Accuracy will be assessed by comparing the planned and actual implant positions using postoperative Cone Beam Computed Tomography (CBCT) superimposition, evaluating coronal, apical, angular, and depth deviations.
Opintotyyppi
Interventio
Ilmoittautuminen (Arvioitu)
26
Vaihe
- Ei sovellettavissa
Yhteystiedot ja paikat
Tässä osiossa on tutkimuksen suorittajien yhteystiedot ja tiedot siitä, missä tämä tutkimus suoritetaan.
Opiskeluyhteys
- Nimi: Aliaa s. Kishk, Batchelor
- Puhelinnumero: +201015101949
- Sähköposti: Aliaa8271staff@dent.tanta.edu.eg
Tutki yhteystietojen varmuuskopiointi
- Nimi: rehab f ghouraba, PHD
- Puhelinnumero: +201211512429
- Sähköposti: rehab_ghouraba@dent.tanta.edu.eg
Opiskelupaikat
-
-
Gharbia Governorate
-
Tanta, Gharbia Governorate, Egypti, 31773
- Rekrytointi
- Periodontology Clinic at Faculty of Dentistry Tanta University
-
Ottaa yhteyttä:
- rehab f ghouraba, PHD
- Puhelinnumero: +201211512429
- Sähköposti: rehab_ghouraba@dent.tanta.edu.eg
-
Ottaa yhteyttä:
- Aliaa S Kishk, Batchelor
- Puhelinnumero: +201015101949
- Sähköposti: Aliaa8271staff@dent.tanta.edu.eg
-
-
Osallistumiskriteerit
Tutkijat etsivät ihmisiä, jotka sopivat tiettyyn kuvaukseen, jota kutsutaan kelpoisuuskriteereiksi. Joitakin esimerkkejä näistä kriteereistä ovat henkilön yleinen terveydentila tai aiemmat hoidot.
Kelpoisuusvaatimukset
Opintokelpoiset iät
- Aikuinen
Hyväksyy terveitä vapaaehtoisia
Ei
Kuvaus
Inclusion Criteria:
- Patients in good health with absence of any relevant medical condition that contraindicates dental implant placement e.g. blood coagulation disorder.
- Optimal compliance is evidenced by no missed treatment appointments and a positive attitude toward oral hygiene.
- Extraction socket type I according to Ellian et al criteria with adequate native/apical bone to achieve primary implant stability and intact buccal plate of bone.
- Thick mucosal phenotype.
- Probing depth ≤ 3 mm at mid-buccal aspect of failing tooth.
- Age ranged from 18- 35 years old of both genders.
Exclusion Criteria:
- Patients subjected to irradiation in the head and neck area.
- Bisphosphonate therapy.
- Females who are pregnant or trying to conceive, and nursing mothers.
- Smokers and uncontrolled diabetic patients.
Opintosuunnitelma
Tässä osiossa on tietoja tutkimussuunnitelmasta, mukaan lukien kuinka tutkimus on suunniteltu ja mitä tutkimuksella mitataan.
Miten tutkimus on suunniteltu?
Suunnittelun yksityiskohdat
- Ensisijainen käyttötarkoitus: Hoito
- Jako: Satunnaistettu
- Inventiomalli: Rinnakkaistehtävä
- Naamiointi: Kaksinkertainen
Aseet ja interventiot
Osallistujaryhmä / Arm |
Interventio / Hoito |
|---|---|
|
Kokeellinen: SocketFit Static Surgical Guide
Participants will undergo immediate implant placement in the anterior esthetic zone using the SocketFit static surgical guide.
The guide incorporates a socket-engaging extension designed to enhance guide stability and drilling accuracy following atraumatic tooth extraction.
Implant placement will be performed according to the planned digital workflow.
|
Participants will undergo immediate implant placement in the anterior esthetic zone using the SocketFit static surgical guide.
The guide incorporates a socket-engaging extension designed to enhance guide stability and drilling accuracy following atraumatic tooth extraction.
Implant placement will be performed according to the planned digital workflow.
|
|
Active Comparator: Conventional Static Surgical Guide
Participants allocated to the control group will undergo immediate implant placement in the anterior esthetic zone using a conventional tooth-supported static surgical guide designed through the standard digital workflow.
Following atraumatic tooth extraction, the guide will be seated on the remaining teeth to direct sequential osteotomy preparation and implant placement according to the preoperative virtual implant plan.
All other surgical procedures, implant system, drilling protocol, and postoperative management will be identical to those used in the experimental group.
|
Participants allocated to the control group will undergo immediate implant placement in the anterior esthetic zone using a conventional tooth-supported static surgical guide designed through the standard digital workflow.
Following atraumatic tooth extraction, the guide will be seated on the remaining teeth to direct sequential osteotomy preparation and implant placement according to the preoperative virtual implant plan.
All other surgical procedures, implant system, drilling protocol, and postoperative management will be identical to those used in the experimental group.
|
Mitä tutkimuksessa mitataan?
Ensisijaiset tulostoimenpiteet
Tulosmittaus |
Toimenpiteen kuvaus |
Aikaikkuna |
|---|---|---|
|
Coronal deviation
Aikaikkuna: Immediately after implant placement following digital superimposition of the planned and actual implant positions.
|
The linear distance (mm) between the planned and actual implant positions at the coronal platform, measured by digital superimposition of the preoperative implant plan and postoperative Cone Beam Computed Tomography (CBCT) data.
|
Immediately after implant placement following digital superimposition of the planned and actual implant positions.
|
|
apical deviation
Aikaikkuna: Immediately after implant placement following digital superimposition of the planned and actual implant positions.
|
The linear distance (mm) between the planned and actual implant positions at the implant apex, measured using digital superimposition of the preoperative implant plan and postoperative Cone Beam Computed Tomography (CBCT) data.
|
Immediately after implant placement following digital superimposition of the planned and actual implant positions.
|
|
depth(vertical) deviation
Aikaikkuna: Immediately after implant placement following digital superimposition of the planned and actual implant positions.
|
The vertical difference (mm) between the planned and actual implant positions along the implant long axis, measured using digital superimposition of the preoperative implant plan and postoperative Cone Beam Computed Tomography (CBCT) data.
|
Immediately after implant placement following digital superimposition of the planned and actual implant positions.
|
|
angular deviation
Aikaikkuna: Immediately after implant placement following digital superimposition of the planned and actual implant positions.
|
The angular difference (degrees) between the long axes of the planned and actual implant positions, measured using digital superimposition of the preoperative implant plan and postoperative Cone Beam Computed Tomography (CBCT) data.
|
Immediately after implant placement following digital superimposition of the planned and actual implant positions.
|
Yhteistyökumppanit ja tutkijat
Täältä löydät tähän tutkimukseen osallistuvat ihmiset ja organisaatiot.
Sponsori
Tutkijat
- Päätutkija: Aliaa s. Kishk, Batchelor, Tanta University
Opintojen ennätyspäivät
Nämä päivämäärät seuraavat ClinicalTrials.gov-sivustolle lähetettyjen tutkimustietueiden ja yhteenvetojen edistymistä. National Library of Medicine (NLM) tarkistaa tutkimustiedot ja raportoidut tulokset varmistaakseen, että ne täyttävät tietyt laadunvalvontastandardit, ennen kuin ne julkaistaan julkisella verkkosivustolla.
Opi tärkeimmät päivämäärät
Opiskelun aloitus (Todellinen)
Lauantai 1. elokuuta 2026
Ensisijainen valmistuminen (Arvioitu)
Torstai 1. heinäkuuta 2027
Opintojen valmistuminen (Arvioitu)
Torstai 1. heinäkuuta 2027
Opintoihin ilmoittautumispäivät
Ensimmäinen lähetetty
Perjantai 7. elokuuta 2026
Ensimmäinen toimitettu, joka täytti QC-kriteerit
Perjantai 7. elokuuta 2026
Ensimmäinen Lähetetty (Todellinen)
Keskiviikko 12. elokuuta 2026
Tutkimustietojen päivitykset
Viimeisin päivitys julkaistu (Todellinen)
Torstai 13. elokuuta 2026
Viimeisin lähetetty päivitys, joka täytti QC-kriteerit
Tiistai 11. elokuuta 2026
Viimeksi vahvistettu
Lauantai 1. elokuuta 2026
Lisää tietoa
Tähän tutkimukseen liittyvät termit
Muut tutkimustunnusnumerot
- 3626
Yksittäisten osallistujien tietojen suunnitelma (IPD)
Aiotko jakaa yksittäisten osallistujien tietoja (IPD)?
EI
IPD-suunnitelman kuvaus
No individual participant data (IPD) will be shared.
All personal identifiers, including names and any information that could identify participants, will be removed before data analysis or sharing.
De-identified Cone Beam Computed Tomography (CBCT) images, Stereolithography (STL ) models, and summary outcome data may be used in scientific publications or presentations in accordance with participant consent, ethical approval, and institutional regulations.
Lääke- ja laitetiedot, tutkimusasiakirjat
Tutkii yhdysvaltalaista FDA sääntelemää lääkevalmistetta
Ei
Tutkii yhdysvaltalaista FDA sääntelemää laitetuotetta
Ei
Nämä tiedot haettiin suoraan verkkosivustolta clinicaltrials.gov ilman muutoksia. Jos sinulla on pyyntöjä muuttaa, poistaa tai päivittää tutkimustietojasi, ota yhteyttä register@clinicaltrials.gov. Heti kun muutos on otettu käyttöön osoitteessa clinicaltrials.gov, se päivitetään automaattisesti myös verkkosivustollemme .