- ICH GCP
- Registro de ensaios clínicos dos EUA
- Ensaio Clínico NCT07760974
Evaluation the Accuracy of Immediate Implant Placement Using SocketFit Static Surgical Guide Versus Conventional Static Surgical Guide in Anterior Esthetic Zone (SocketFit)
11 de agosto de 2026 atualizado por: Aliaa Saeed Kishk, Tanta University
This study compares two types of surgical guides used during immediate dental implant placement in the upper front teeth.
One guide is a conventional static surgical guide, while the other is a modified SocketFit static surgical guide designed to improve stability after tooth extraction.
The purpose of the study is to determine whether the SocketFit guide improves the accuracy of implant placement.The findings may help improve the precision and predictability of immediate dental implant treatment in the anterior esthetic zone.
Visão geral do estudo
Status
Recrutamento
Intervenção / Tratamento
Descrição detalhada
Immediate implant placement in the anterior esthetic zone is a predictable treatment option that reduces treatment time and preserves peri-implant soft and hard tissues.
Static computer-guided surgery has improved the accuracy of implant placement; however, guide stability may be compromised immediately after tooth extraction because of complex morphology and angulation of post-extraction sockets, as well as variations in bone density.These factors can lead to surgical drill displacement, causing the implant to deviate from its intended trajectory.Therefore, The SocketFit static surgical guide incorporates a socket-engaging extension designed to enhance guide seating and stability during osteotomy preparation.
Limited evidence is available regarding the accuracy of this modified guide compared with the conventional tooth-supported static surgical guide.
Therefore, this study aims to evaluate the accuracy of immediate implant placement using the SocketFit static surgical guide versus the conventional static surgical guide in the anterior esthetic zone.
Accuracy will be assessed by comparing the planned and actual implant positions using postoperative Cone Beam Computed Tomography (CBCT) superimposition, evaluating coronal, apical, angular, and depth deviations.
Tipo de estudo
Intervencional
Inscrição (Estimado)
26
Estágio
- Não aplicável
Contactos e Locais
Esta seção fornece os detalhes de contato para aqueles que conduzem o estudo e informações sobre onde este estudo está sendo realizado.
Contato de estudo
- Nome: Aliaa s. Kishk, Batchelor
- Número de telefone: +201015101949
- E-mail: Aliaa8271staff@dent.tanta.edu.eg
Estude backup de contato
- Nome: rehab f ghouraba, PHD
- Número de telefone: +201211512429
- E-mail: rehab_ghouraba@dent.tanta.edu.eg
Locais de estudo
-
-
Gharbia Governorate
-
Tanta, Gharbia Governorate, Egito, 31773
- Recrutamento
- Periodontology Clinic at Faculty of Dentistry Tanta University
-
Contato:
- rehab f ghouraba, PHD
- Número de telefone: +201211512429
- E-mail: rehab_ghouraba@dent.tanta.edu.eg
-
Contato:
- Aliaa S Kishk, Batchelor
- Número de telefone: +201015101949
- E-mail: Aliaa8271staff@dent.tanta.edu.eg
-
-
Critérios de participação
Os pesquisadores procuram pessoas que se encaixem em uma determinada descrição, chamada de critérios de elegibilidade. Alguns exemplos desses critérios são a condição geral de saúde de uma pessoa ou tratamentos anteriores.
Critérios de elegibilidade
Idades elegíveis para estudo
- Adulto
Aceita Voluntários Saudáveis
Não
Descrição
Inclusion Criteria:
- Patients in good health with absence of any relevant medical condition that contraindicates dental implant placement e.g. blood coagulation disorder.
- Optimal compliance is evidenced by no missed treatment appointments and a positive attitude toward oral hygiene.
- Extraction socket type I according to Ellian et al criteria with adequate native/apical bone to achieve primary implant stability and intact buccal plate of bone.
- Thick mucosal phenotype.
- Probing depth ≤ 3 mm at mid-buccal aspect of failing tooth.
- Age ranged from 18- 35 years old of both genders.
Exclusion Criteria:
- Patients subjected to irradiation in the head and neck area.
- Bisphosphonate therapy.
- Females who are pregnant or trying to conceive, and nursing mothers.
- Smokers and uncontrolled diabetic patients.
Plano de estudo
Esta seção fornece detalhes do plano de estudo, incluindo como o estudo é projetado e o que o estudo está medindo.
Como o estudo é projetado?
Detalhes do projeto
- Finalidade Principal: Tratamento
- Alocação: Randomizado
- Modelo Intervencional: Atribuição Paralela
- Mascaramento: Dobro
Armas e Intervenções
Grupo de Participantes / Braço |
Intervenção / Tratamento |
|---|---|
|
Experimental: SocketFit Static Surgical Guide
Participants will undergo immediate implant placement in the anterior esthetic zone using the SocketFit static surgical guide.
The guide incorporates a socket-engaging extension designed to enhance guide stability and drilling accuracy following atraumatic tooth extraction.
Implant placement will be performed according to the planned digital workflow.
|
Participants will undergo immediate implant placement in the anterior esthetic zone using the SocketFit static surgical guide.
The guide incorporates a socket-engaging extension designed to enhance guide stability and drilling accuracy following atraumatic tooth extraction.
Implant placement will be performed according to the planned digital workflow.
|
|
Comparador Ativo: Conventional Static Surgical Guide
Participants allocated to the control group will undergo immediate implant placement in the anterior esthetic zone using a conventional tooth-supported static surgical guide designed through the standard digital workflow.
Following atraumatic tooth extraction, the guide will be seated on the remaining teeth to direct sequential osteotomy preparation and implant placement according to the preoperative virtual implant plan.
All other surgical procedures, implant system, drilling protocol, and postoperative management will be identical to those used in the experimental group.
|
Participants allocated to the control group will undergo immediate implant placement in the anterior esthetic zone using a conventional tooth-supported static surgical guide designed through the standard digital workflow.
Following atraumatic tooth extraction, the guide will be seated on the remaining teeth to direct sequential osteotomy preparation and implant placement according to the preoperative virtual implant plan.
All other surgical procedures, implant system, drilling protocol, and postoperative management will be identical to those used in the experimental group.
|
O que o estudo está medindo?
Medidas de resultados primários
Medida de resultado |
Descrição da medida |
Prazo |
|---|---|---|
|
Coronal deviation
Prazo: Immediately after implant placement following digital superimposition of the planned and actual implant positions.
|
The linear distance (mm) between the planned and actual implant positions at the coronal platform, measured by digital superimposition of the preoperative implant plan and postoperative Cone Beam Computed Tomography (CBCT) data.
|
Immediately after implant placement following digital superimposition of the planned and actual implant positions.
|
|
apical deviation
Prazo: Immediately after implant placement following digital superimposition of the planned and actual implant positions.
|
The linear distance (mm) between the planned and actual implant positions at the implant apex, measured using digital superimposition of the preoperative implant plan and postoperative Cone Beam Computed Tomography (CBCT) data.
|
Immediately after implant placement following digital superimposition of the planned and actual implant positions.
|
|
depth(vertical) deviation
Prazo: Immediately after implant placement following digital superimposition of the planned and actual implant positions.
|
The vertical difference (mm) between the planned and actual implant positions along the implant long axis, measured using digital superimposition of the preoperative implant plan and postoperative Cone Beam Computed Tomography (CBCT) data.
|
Immediately after implant placement following digital superimposition of the planned and actual implant positions.
|
|
angular deviation
Prazo: Immediately after implant placement following digital superimposition of the planned and actual implant positions.
|
The angular difference (degrees) between the long axes of the planned and actual implant positions, measured using digital superimposition of the preoperative implant plan and postoperative Cone Beam Computed Tomography (CBCT) data.
|
Immediately after implant placement following digital superimposition of the planned and actual implant positions.
|
Colaboradores e Investigadores
É aqui que você encontrará pessoas e organizações envolvidas com este estudo.
Patrocinador
Investigadores
- Investigador principal: Aliaa s. Kishk, Batchelor, Tanta University
Datas de registro do estudo
Essas datas acompanham o progresso do registro do estudo e os envios de resumo dos resultados para ClinicalTrials.gov. Os registros do estudo e os resultados relatados são revisados pela National Library of Medicine (NLM) para garantir que atendam aos padrões específicos de controle de qualidade antes de serem publicados no site público.
Datas Principais do Estudo
Início do estudo (Real)
1 de agosto de 2026
Conclusão Primária (Estimado)
1 de julho de 2027
Conclusão do estudo (Estimado)
1 de julho de 2027
Datas de inscrição no estudo
Enviado pela primeira vez
7 de agosto de 2026
Enviado pela primeira vez que atendeu aos critérios de CQ
7 de agosto de 2026
Primeira postagem (Real)
12 de agosto de 2026
Atualizações de registro de estudo
Última Atualização Postada (Real)
13 de agosto de 2026
Última atualização enviada que atendeu aos critérios de controle de qualidade
11 de agosto de 2026
Última verificação
1 de agosto de 2026
Mais Informações
Termos relacionados a este estudo
Outros números de identificação do estudo
- 3626
Plano para dados de participantes individuais (IPD)
Planeja compartilhar dados de participantes individuais (IPD)?
NÃO
Descrição do plano IPD
No individual participant data (IPD) will be shared.
All personal identifiers, including names and any information that could identify participants, will be removed before data analysis or sharing.
De-identified Cone Beam Computed Tomography (CBCT) images, Stereolithography (STL ) models, and summary outcome data may be used in scientific publications or presentations in accordance with participant consent, ethical approval, and institutional regulations.
Informações sobre medicamentos e dispositivos, documentos de estudo
Estuda um medicamento regulamentado pela FDA dos EUA
Não
Estuda um produto de dispositivo regulamentado pela FDA dos EUA
Não
Essas informações foram obtidas diretamente do site clinicaltrials.gov sem nenhuma alteração. Se você tiver alguma solicitação para alterar, remover ou atualizar os detalhes do seu estudo, entre em contato com register@clinicaltrials.gov. Assim que uma alteração for implementada em clinicaltrials.gov, ela também será atualizada automaticamente em nosso site .