Esta página se tradujo automáticamente y no se garantiza la precisión de la traducción. por favor refiérase a versión inglesa para un texto fuente.

Evaluation the Accuracy of Immediate Implant Placement Using SocketFit Static Surgical Guide Versus Conventional Static Surgical Guide in Anterior Esthetic Zone (SocketFit)

11 de agosto de 2026 actualizado por: Aliaa Saeed Kishk, Tanta University
This study compares two types of surgical guides used during immediate dental implant placement in the upper front teeth. One guide is a conventional static surgical guide, while the other is a modified SocketFit static surgical guide designed to improve stability after tooth extraction. The purpose of the study is to determine whether the SocketFit guide improves the accuracy of implant placement.The findings may help improve the precision and predictability of immediate dental implant treatment in the anterior esthetic zone.

Descripción general del estudio

Descripción detallada

Immediate implant placement in the anterior esthetic zone is a predictable treatment option that reduces treatment time and preserves peri-implant soft and hard tissues. Static computer-guided surgery has improved the accuracy of implant placement; however, guide stability may be compromised immediately after tooth extraction because of complex morphology and angulation of post-extraction sockets, as well as variations in bone density.These factors can lead to surgical drill displacement, causing the implant to deviate from its intended trajectory.Therefore, The SocketFit static surgical guide incorporates a socket-engaging extension designed to enhance guide seating and stability during osteotomy preparation. Limited evidence is available regarding the accuracy of this modified guide compared with the conventional tooth-supported static surgical guide. Therefore, this study aims to evaluate the accuracy of immediate implant placement using the SocketFit static surgical guide versus the conventional static surgical guide in the anterior esthetic zone. Accuracy will be assessed by comparing the planned and actual implant positions using postoperative Cone Beam Computed Tomography (CBCT) superimposition, evaluating coronal, apical, angular, and depth deviations.

Tipo de estudio

Intervencionista

Inscripción (Estimado)

26

Fase

  • No aplica

Contactos y Ubicaciones

Esta sección proporciona los datos de contacto de quienes realizan el estudio e información sobre dónde se lleva a cabo este estudio.

Estudio Contacto

Copia de seguridad de contactos de estudio

Ubicaciones de estudio

    • Gharbia Governorate
      • Tanta, Gharbia Governorate, Egipto, 31773
        • Reclutamiento
        • Periodontology Clinic at Faculty of Dentistry Tanta University
        • Contacto:
        • Contacto:

Criterios de participación

Los investigadores buscan personas que se ajusten a una determinada descripción, denominada criterio de elegibilidad. Algunos ejemplos de estos criterios son el estado de salud general de una persona o tratamientos previos.

Criterio de elegibilidad

Edades elegibles para estudiar

  • Adulto

Acepta Voluntarios Saludables

No

Descripción

Inclusion Criteria:

  • Patients in good health with absence of any relevant medical condition that contraindicates dental implant placement e.g. blood coagulation disorder.
  • Optimal compliance is evidenced by no missed treatment appointments and a positive attitude toward oral hygiene.
  • Extraction socket type I according to Ellian et al criteria with adequate native/apical bone to achieve primary implant stability and intact buccal plate of bone.
  • Thick mucosal phenotype.
  • Probing depth ≤ 3 mm at mid-buccal aspect of failing tooth.
  • Age ranged from 18- 35 years old of both genders.

Exclusion Criteria:

  • Patients subjected to irradiation in the head and neck area.
  • Bisphosphonate therapy.
  • Females who are pregnant or trying to conceive, and nursing mothers.
  • Smokers and uncontrolled diabetic patients.

Plan de estudios

Esta sección proporciona detalles del plan de estudio, incluido cómo está diseñado el estudio y qué mide el estudio.

¿Cómo está diseñado el estudio?

Detalles de diseño

  • Propósito principal: Tratamiento
  • Asignación: Aleatorizado
  • Modelo Intervencionista: Asignación paralela
  • Enmascaramiento: Doble

Armas e Intervenciones

Grupo de participantes/brazo
Intervención / Tratamiento
Experimental: SocketFit Static Surgical Guide
Participants will undergo immediate implant placement in the anterior esthetic zone using the SocketFit static surgical guide. The guide incorporates a socket-engaging extension designed to enhance guide stability and drilling accuracy following atraumatic tooth extraction. Implant placement will be performed according to the planned digital workflow.
Participants will undergo immediate implant placement in the anterior esthetic zone using the SocketFit static surgical guide. The guide incorporates a socket-engaging extension designed to enhance guide stability and drilling accuracy following atraumatic tooth extraction. Implant placement will be performed according to the planned digital workflow.
Comparador activo: Conventional Static Surgical Guide
Participants allocated to the control group will undergo immediate implant placement in the anterior esthetic zone using a conventional tooth-supported static surgical guide designed through the standard digital workflow. Following atraumatic tooth extraction, the guide will be seated on the remaining teeth to direct sequential osteotomy preparation and implant placement according to the preoperative virtual implant plan. All other surgical procedures, implant system, drilling protocol, and postoperative management will be identical to those used in the experimental group.
Participants allocated to the control group will undergo immediate implant placement in the anterior esthetic zone using a conventional tooth-supported static surgical guide designed through the standard digital workflow. Following atraumatic tooth extraction, the guide will be seated on the remaining teeth to direct sequential osteotomy preparation and implant placement according to the preoperative virtual implant plan. All other surgical procedures, implant system, drilling protocol, and postoperative management will be identical to those used in the experimental group.

¿Qué mide el estudio?

Medidas de resultado primarias

Medida de resultado
Medida Descripción
Periodo de tiempo
Coronal deviation
Periodo de tiempo: Immediately after implant placement following digital superimposition of the planned and actual implant positions.
The linear distance (mm) between the planned and actual implant positions at the coronal platform, measured by digital superimposition of the preoperative implant plan and postoperative Cone Beam Computed Tomography (CBCT) data.
Immediately after implant placement following digital superimposition of the planned and actual implant positions.
apical deviation
Periodo de tiempo: Immediately after implant placement following digital superimposition of the planned and actual implant positions.
The linear distance (mm) between the planned and actual implant positions at the implant apex, measured using digital superimposition of the preoperative implant plan and postoperative Cone Beam Computed Tomography (CBCT) data.
Immediately after implant placement following digital superimposition of the planned and actual implant positions.
depth(vertical) deviation
Periodo de tiempo: Immediately after implant placement following digital superimposition of the planned and actual implant positions.
The vertical difference (mm) between the planned and actual implant positions along the implant long axis, measured using digital superimposition of the preoperative implant plan and postoperative Cone Beam Computed Tomography (CBCT) data.
Immediately after implant placement following digital superimposition of the planned and actual implant positions.
angular deviation
Periodo de tiempo: Immediately after implant placement following digital superimposition of the planned and actual implant positions.
The angular difference (degrees) between the long axes of the planned and actual implant positions, measured using digital superimposition of the preoperative implant plan and postoperative Cone Beam Computed Tomography (CBCT) data.
Immediately after implant placement following digital superimposition of the planned and actual implant positions.

Colaboradores e Investigadores

Aquí es donde encontrará personas y organizaciones involucradas en este estudio.

Patrocinador

Investigadores

  • Investigador principal: Aliaa s. Kishk, Batchelor, Tanta University

Fechas de registro del estudio

Estas fechas rastrean el progreso del registro del estudio y los envíos de resultados resumidos a ClinicalTrials.gov. Los registros del estudio y los resultados informados son revisados ​​por la Biblioteca Nacional de Medicina (NLM) para asegurarse de que cumplan con los estándares de control de calidad específicos antes de publicarlos en el sitio web público.

Fechas importantes del estudio

Inicio del estudio (Actual)

1 de agosto de 2026

Finalización primaria (Estimado)

1 de julio de 2027

Finalización del estudio (Estimado)

1 de julio de 2027

Fechas de registro del estudio

Enviado por primera vez

7 de agosto de 2026

Primero enviado que cumplió con los criterios de control de calidad

7 de agosto de 2026

Publicado por primera vez (Actual)

12 de agosto de 2026

Actualizaciones de registros de estudio

Última actualización publicada (Actual)

13 de agosto de 2026

Última actualización enviada que cumplió con los criterios de control de calidad

11 de agosto de 2026

Última verificación

1 de agosto de 2026

Más información

Términos relacionados con este estudio

Otros números de identificación del estudio

  • 3626

Plan de datos de participantes individuales (IPD)

¿Planea compartir datos de participantes individuales (IPD)?

NO

Descripción del plan IPD

No individual participant data (IPD) will be shared. All personal identifiers, including names and any information that could identify participants, will be removed before data analysis or sharing. De-identified Cone Beam Computed Tomography (CBCT) images, Stereolithography (STL ) models, and summary outcome data may be used in scientific publications or presentations in accordance with participant consent, ethical approval, and institutional regulations.

Información sobre medicamentos y dispositivos, documentos del estudio

Estudia un producto farmacéutico regulado por la FDA de EE. UU.

No

Estudia un producto de dispositivo regulado por la FDA de EE. UU.

No

Esta información se obtuvo directamente del sitio web clinicaltrials.gov sin cambios. Si tiene alguna solicitud para cambiar, eliminar o actualizar los detalles de su estudio, comuníquese con register@clinicaltrials.gov. Tan pronto como se implemente un cambio en clinicaltrials.gov, también se actualizará automáticamente en nuestro sitio web. .

Suscribir