- ICH GCP
- Register voor klinische proeven in de VS.
- Klinische proef NCT07760974
Evaluation the Accuracy of Immediate Implant Placement Using SocketFit Static Surgical Guide Versus Conventional Static Surgical Guide in Anterior Esthetic Zone (SocketFit)
11 augustus 2026 bijgewerkt door: Aliaa Saeed Kishk, Tanta University
This study compares two types of surgical guides used during immediate dental implant placement in the upper front teeth.
One guide is a conventional static surgical guide, while the other is a modified SocketFit static surgical guide designed to improve stability after tooth extraction.
The purpose of the study is to determine whether the SocketFit guide improves the accuracy of implant placement.The findings may help improve the precision and predictability of immediate dental implant treatment in the anterior esthetic zone.
Studie Overzicht
Toestand
Werving
Interventie / Behandeling
Gedetailleerde beschrijving
Immediate implant placement in the anterior esthetic zone is a predictable treatment option that reduces treatment time and preserves peri-implant soft and hard tissues.
Static computer-guided surgery has improved the accuracy of implant placement; however, guide stability may be compromised immediately after tooth extraction because of complex morphology and angulation of post-extraction sockets, as well as variations in bone density.These factors can lead to surgical drill displacement, causing the implant to deviate from its intended trajectory.Therefore, The SocketFit static surgical guide incorporates a socket-engaging extension designed to enhance guide seating and stability during osteotomy preparation.
Limited evidence is available regarding the accuracy of this modified guide compared with the conventional tooth-supported static surgical guide.
Therefore, this study aims to evaluate the accuracy of immediate implant placement using the SocketFit static surgical guide versus the conventional static surgical guide in the anterior esthetic zone.
Accuracy will be assessed by comparing the planned and actual implant positions using postoperative Cone Beam Computed Tomography (CBCT) superimposition, evaluating coronal, apical, angular, and depth deviations.
Studietype
Ingrijpend
Inschrijving (Geschat)
26
Fase
- Niet toepasbaar
Contacten en locaties
In dit gedeelte vindt u de contactgegevens van degenen die het onderzoek uitvoeren en informatie over waar dit onderzoek wordt uitgevoerd.
Studiecontact
- Naam: Aliaa s. Kishk, Batchelor
- Telefoonnummer: +201015101949
- E-mail: Aliaa8271staff@dent.tanta.edu.eg
Studie Contact Back-up
- Naam: rehab f ghouraba, PHD
- Telefoonnummer: +201211512429
- E-mail: rehab_ghouraba@dent.tanta.edu.eg
Studie Locaties
-
-
Gharbia Governorate
-
Tanta, Gharbia Governorate, Egypte, 31773
- Werving
- Periodontology Clinic at Faculty of Dentistry Tanta University
-
Contact:
- rehab f ghouraba, PHD
- Telefoonnummer: +201211512429
- E-mail: rehab_ghouraba@dent.tanta.edu.eg
-
Contact:
- Aliaa S Kishk, Batchelor
- Telefoonnummer: +201015101949
- E-mail: Aliaa8271staff@dent.tanta.edu.eg
-
-
Deelname Criteria
Onderzoekers zoeken naar mensen die aan een bepaalde beschrijving voldoen, de zogenaamde geschiktheidscriteria. Enkele voorbeelden van deze criteria zijn iemands algemene gezondheidstoestand of eerdere behandelingen.
Geschiktheidscriteria
Leeftijden die in aanmerking komen voor studie
- Volwassen
Accepteert gezonde vrijwilligers
Nee
Beschrijving
Inclusion Criteria:
- Patients in good health with absence of any relevant medical condition that contraindicates dental implant placement e.g. blood coagulation disorder.
- Optimal compliance is evidenced by no missed treatment appointments and a positive attitude toward oral hygiene.
- Extraction socket type I according to Ellian et al criteria with adequate native/apical bone to achieve primary implant stability and intact buccal plate of bone.
- Thick mucosal phenotype.
- Probing depth ≤ 3 mm at mid-buccal aspect of failing tooth.
- Age ranged from 18- 35 years old of both genders.
Exclusion Criteria:
- Patients subjected to irradiation in the head and neck area.
- Bisphosphonate therapy.
- Females who are pregnant or trying to conceive, and nursing mothers.
- Smokers and uncontrolled diabetic patients.
Studie plan
Dit gedeelte bevat details van het studieplan, inclusief hoe de studie is opgezet en wat de studie meet.
Hoe is de studie opgezet?
Ontwerpdetails
- Primair doel: Behandeling
- Toewijzing: Gerandomiseerd
- Interventioneel model: Parallelle opdracht
- Masker: Dubbele
Wapens en interventies
Deelnemersgroep / Arm |
Interventie / Behandeling |
|---|---|
|
Experimenteel: SocketFit Static Surgical Guide
Participants will undergo immediate implant placement in the anterior esthetic zone using the SocketFit static surgical guide.
The guide incorporates a socket-engaging extension designed to enhance guide stability and drilling accuracy following atraumatic tooth extraction.
Implant placement will be performed according to the planned digital workflow.
|
Participants will undergo immediate implant placement in the anterior esthetic zone using the SocketFit static surgical guide.
The guide incorporates a socket-engaging extension designed to enhance guide stability and drilling accuracy following atraumatic tooth extraction.
Implant placement will be performed according to the planned digital workflow.
|
|
Actieve vergelijker: Conventional Static Surgical Guide
Participants allocated to the control group will undergo immediate implant placement in the anterior esthetic zone using a conventional tooth-supported static surgical guide designed through the standard digital workflow.
Following atraumatic tooth extraction, the guide will be seated on the remaining teeth to direct sequential osteotomy preparation and implant placement according to the preoperative virtual implant plan.
All other surgical procedures, implant system, drilling protocol, and postoperative management will be identical to those used in the experimental group.
|
Participants allocated to the control group will undergo immediate implant placement in the anterior esthetic zone using a conventional tooth-supported static surgical guide designed through the standard digital workflow.
Following atraumatic tooth extraction, the guide will be seated on the remaining teeth to direct sequential osteotomy preparation and implant placement according to the preoperative virtual implant plan.
All other surgical procedures, implant system, drilling protocol, and postoperative management will be identical to those used in the experimental group.
|
Wat meet het onderzoek?
Primaire uitkomstmaten
Uitkomstmaat |
Maatregel Beschrijving |
Tijdsspanne |
|---|---|---|
|
Coronal deviation
Tijdsspanne: Immediately after implant placement following digital superimposition of the planned and actual implant positions.
|
The linear distance (mm) between the planned and actual implant positions at the coronal platform, measured by digital superimposition of the preoperative implant plan and postoperative Cone Beam Computed Tomography (CBCT) data.
|
Immediately after implant placement following digital superimposition of the planned and actual implant positions.
|
|
apical deviation
Tijdsspanne: Immediately after implant placement following digital superimposition of the planned and actual implant positions.
|
The linear distance (mm) between the planned and actual implant positions at the implant apex, measured using digital superimposition of the preoperative implant plan and postoperative Cone Beam Computed Tomography (CBCT) data.
|
Immediately after implant placement following digital superimposition of the planned and actual implant positions.
|
|
depth(vertical) deviation
Tijdsspanne: Immediately after implant placement following digital superimposition of the planned and actual implant positions.
|
The vertical difference (mm) between the planned and actual implant positions along the implant long axis, measured using digital superimposition of the preoperative implant plan and postoperative Cone Beam Computed Tomography (CBCT) data.
|
Immediately after implant placement following digital superimposition of the planned and actual implant positions.
|
|
angular deviation
Tijdsspanne: Immediately after implant placement following digital superimposition of the planned and actual implant positions.
|
The angular difference (degrees) between the long axes of the planned and actual implant positions, measured using digital superimposition of the preoperative implant plan and postoperative Cone Beam Computed Tomography (CBCT) data.
|
Immediately after implant placement following digital superimposition of the planned and actual implant positions.
|
Medewerkers en onderzoekers
Hier vindt u mensen en organisaties die betrokken zijn bij dit onderzoek.
Sponsor
Onderzoekers
- Hoofdonderzoeker: Aliaa s. Kishk, Batchelor, Tanta University
Studie record data
Deze datums volgen de voortgang van het onderzoeksdossier en de samenvatting van de ingediende resultaten bij ClinicalTrials.gov. Studieverslagen en gerapporteerde resultaten worden beoordeeld door de National Library of Medicine (NLM) om er zeker van te zijn dat ze voldoen aan specifieke kwaliteitscontrolenormen voordat ze op de openbare website worden geplaatst.
Bestudeer belangrijke data
Studie start (Werkelijk)
1 augustus 2026
Primaire voltooiing (Geschat)
1 juli 2027
Studie voltooiing (Geschat)
1 juli 2027
Studieregistratiedata
Eerst ingediend
7 augustus 2026
Eerst ingediend dat voldeed aan de QC-criteria
7 augustus 2026
Eerst geplaatst (Werkelijk)
12 augustus 2026
Updates van studierecords
Laatste update geplaatst (Werkelijk)
13 augustus 2026
Laatste update ingediend die voldeed aan QC-criteria
11 augustus 2026
Laatst geverifieerd
1 augustus 2026
Meer informatie
Termen gerelateerd aan deze studie
Andere studie-ID-nummers
- 3626
Plan Individuele Deelnemersgegevens (IPD)
Bent u van plan om gegevens van individuele deelnemers (IPD) te delen?
NEE
Beschrijving IPD-plan
No individual participant data (IPD) will be shared.
All personal identifiers, including names and any information that could identify participants, will be removed before data analysis or sharing.
De-identified Cone Beam Computed Tomography (CBCT) images, Stereolithography (STL ) models, and summary outcome data may be used in scientific publications or presentations in accordance with participant consent, ethical approval, and institutional regulations.
Informatie over medicijnen en apparaten, studiedocumenten
Bestudeert een door de Amerikaanse FDA gereguleerd geneesmiddel
Nee
Bestudeert een door de Amerikaanse FDA gereguleerd apparaatproduct
Nee
Deze informatie is zonder wijzigingen rechtstreeks van de website clinicaltrials.gov gehaald. Als u verzoeken heeft om uw onderzoeksgegevens te wijzigen, te verwijderen of bij te werken, neem dan contact op met register@clinicaltrials.gov. Zodra er een wijziging wordt doorgevoerd op clinicaltrials.gov, wordt deze ook automatisch bijgewerkt op onze website .