A Registry Evaluating the Real-World Clinical Use, Procedural Characteristics, Safety, and Effectiveness of the VARIPULSE™ PRO Pulsed Field Ablation Platform for the Treatment of Atrial Fibrillation

13 novembre 2026 mis à jour par: Waterloo Regional Health Network

Real-World Outcomes and Procedural Practice Patterns of VARIPULSE™ PRO Ablation for Atrial Fibrillation

The purpose of this study is to learn more about how safe and how well a treatment called catheter ablation works to treat atrial fibrillation (AF) when the VARIPULSE system is used.

This study collects information from people receiving this treatment as part of their usual medical care. Researchers want to understand how the procedure is used in everyday practice.

The secondary purpose of this study is to create a registry to collect data to be used for future research.

Aperçu de l'étude

Statut

Pas encore de recrutement

Les conditions

Intervention / Traitement

Type d'étude

Observationnel

Inscription (Estimé)

500

Contacts et emplacements

Cette section fournit les coordonnées de ceux qui mènent l'étude et des informations sur le lieu où cette étude est menée.

Coordonnées de l'étude

Critères de participation

Les chercheurs recherchent des personnes qui correspondent à une certaine description, appelée critères d'éligibilité. Certains exemples de ces critères sont l'état de santé général d'une personne ou des traitements antérieurs.

Critère d'éligibilité

Âges éligibles pour étudier

18 ans et plus (Adulte, Adulte plus âgé)

Accepte les volontaires sains

Non

Sexes éligibles pour l'étude

Tout

Méthode d'échantillonnage

Échantillon non probabiliste

Population étudiée

Patients undergoing catheter ablation for atrial fibrillation using the VARIPULSE PRO platform.

La description

Inclusion Criteria:

  • Symptomatic paroxysmal atrial fibrillation (AF episode that terminates spontaneously within 7 days)
  • Indicated for catheter ablation in the opinion of the investigator
  • De Novo and redo AF ablation procedures
  • Age > 18 years
  • Will be treated with Biosense Webster Inc. Ablation Technologies
  • All AF ablations performed with BWI technology.
  • Able and willing to participate in baseline and follow-up evaluations.

Exclusion Criteria:

  • Age <18 years
  • Persistent atrial fibrillation
  • Non-AF ablation procedures without AF treatment
  • Inability to provide informed consent
  • Enrolled in an investigational drug or device clinical trial, or any trial that dictates the treatment plan
  • In the opinion of the investigator, any known contraindication to an ablation procedure

Plan d'étude

Cette section fournit des détails sur le plan d'étude, y compris la façon dont l'étude est conçue et ce que l'étude mesure.

Comment l'étude est-elle conçue ?

Détails de conception

  • Modèles d'observation: OTHER
  • Perspectives temporelles: OTHER

Que mesure l'étude ?

Principaux critères de jugement

Mesure des résultats
Description de la mesure
Délai
Procedural Characteristics and Lesion Delivery Patterns of VARIPULSE™-Based Atrial Fibrillation Ablation Using the PRO Sequence
Délai: During the index ablation procedure.

To characterize real-world procedural practices associated with VARIPULSE™ pulsed field ablation using the PRO sequence in patients undergoing atrial fibrillation ablation. Measures will include total number of PFA applications, number of applications delivered per pulmonary vein, lesion distribution within the left atrium, completeness of pulmonary vein lesion sets, and use of adjunctive ablation strategies. Additional lesion sets, including posterior wall isolation, roof line, mitral isthmus, cavotricuspid isthmus, anterior wall and other mapped atrial tachycardia targets, will also be documented.

During the index ablation procedure.
Procedural Workflow and Efficiency Metrics
Délai: During the index ablation procedure.

To evaluate procedural workflow, duration and resource utilization during VARIPULSE™-based atrial fibrillation ablation. Measures will include total procedure duration, left atrial dwell time, fluoroscopy time, radiation dose, number of transseptal punctures, total ablation time, and use of adjunctive ablation technologies, including supplemental radiofrequency ablation. Additional procedural characteristics will include anesthesia type, ventilation strategy, intracardiac echocardiography utilization, electroanatomical mapping workflow and left atrial voltage map acquisition.

During the index ablation procedure.
Pulmonary Vein Lesion Delivery and Isolation Characteristics
Délai: During the index ablation procedure.

To characterize pulmonary vein lesion delivery and isolation efficiency during VARIPULSE™ PFA procedures using the PRO sequence. Measures will include total lesions delivered, number of lesions per pulmonary vein, completeness of concentric lesion rings, number of lesions required to achieve pulmonary vein isolation, and pulmonary vein isolation transpired time. Pulmonary vein isolation transpired time is defined as the interval between the first and final pulmonary vein ablation applications, excluding subsequent touch-up lesions performed following additional linear lesion sets.

During the index ablation procedure.

Collaborateurs et enquêteurs

C'est ici que vous trouverez les personnes et les organisations impliquées dans cette étude.

Parrainer

Dates d'enregistrement des études

Ces dates suivent la progression des dossiers d'étude et des soumissions de résultats sommaires à ClinicalTrials.gov. Les dossiers d'étude et les résultats rapportés sont examinés par la Bibliothèque nationale de médecine (NLM) pour s'assurer qu'ils répondent à des normes de contrôle de qualité spécifiques avant d'être publiés sur le site Web public.

Dates principales de l'étude

Début de l'étude (Estimé)

1 novembre 2026

Achèvement primaire (Estimé)

1 novembre 2027

Achèvement de l'étude (Estimé)

1 février 2028

Dates d'inscription aux études

Première soumission

4 novembre 2026

Première soumission répondant aux critères de contrôle qualité

13 novembre 2026

Première publication (Réel)

17 novembre 2026

Mises à jour des dossiers d'étude

Dernière mise à jour publiée (Réel)

17 novembre 2026

Dernière mise à jour soumise répondant aux critères de contrôle qualité

13 novembre 2026

Dernière vérification

1 novembre 2026

Plus d'information

Termes liés à cette étude

Autres numéros d'identification d'étude

  • VANTAGE-AF

Plan pour les données individuelles des participants (IPD)

Prévoyez-vous de partager les données individuelles des participants (DPI) ?

INDÉCIS

Informations sur les médicaments et les dispositifs, documents d'étude

Étudie un produit pharmaceutique réglementé par la FDA américaine

Non

Étudie un produit d'appareil réglementé par la FDA américaine

Non

Ces informations ont été extraites directement du site Web clinicaltrials.gov sans aucune modification. Si vous avez des demandes de modification, de suppression ou de mise à jour des détails de votre étude, veuillez contacter register@clinicaltrials.gov. Dès qu'un changement est mis en œuvre sur clinicaltrials.gov, il sera également mis à jour automatiquement sur notre site Web .