- ICH GCP
- Registre américain des essais cliniques
- Essai clinique NCT01487330
First in Human Experience of the St. Jude Medical TAVI Valve and Delivery System (SJM TAVI FIH)
First In Human Experience and Assessment of the 23mm SJM Transcatheter Aortic Valve Implant and the SJM TAVI Transfemoral Delivery System (SJM TAVI FIH)
The purpose of this first-in-human study is to assess the technical feasibility, deployment characteristics, and safety of the 23mm SJM Transfemoral Transcatheter Heart Valve and delivery system in subjects with severe symptomatic aortic stenosis (AS).
This is a single center, prospective, non-randomized, first-in-human investigational study without concurrent or matched controls.
Aperçu de l'étude
Statut
Les conditions
Intervention / Traitement
Description détaillée
Type d'étude
Inscription (Réel)
Phase
- N'est pas applicable
Contacts et emplacements
Lieux d'étude
-
-
-
Belfast, Royaume-Uni
- Royal Victoria Hospital
-
-
Critères de participation
Critère d'éligibilité
Âges éligibles pour étudier
Accepte les volontaires sains
Sexes éligibles pour l'étude
La description
Inclusion Criteria:
- Written Informed Consent for participation prior to procedure.
- Legal age in host country.
- Aortic annulus 19-21mm diameter
- Senile degenerative aortic stenosis with derived mean gradient >40mmHg or jet velocity greater than 4.0 m/s or an initial valve area of <1.0 cm2 (or aortic valve area index ≤ 0.6 cm2/m2)
- NYHA Functional Classification of II or greater.
- Predicted operative mortality or serious, irreversible morbidity risk is <50% at 30 days.
- Suitable peripheral vessels and aorta to allow for access of the 18 French delivery system.
Exclusion Criteria:
- History of a cerebral vascular accident (CVA) or transient ischemic attack (TIA) within the past 6 months (≤180 days) of index procedure.
- Carotid artery disease requiring intervention.
- Myocardial infarction (MI) within 6 months (≤180 days) of the index procedure.
- Native aortic valve that is congenitally unicuspid, bicuspid, quadricuspid or non-calcified as seen by echocardiography.
- Mitral or tricuspid valvular regurgitation (grade II) or moderate to severe mitral stenosis.
- Aortic root angulation >70 degrees (horizontal aorta).
- Pre-existing prosthetic valve or prosthetic ring in any position. LVEF < 20%.
- Untreated coronary artery disease (CAD) requiring revascularization.
- Severe basal septal hypertrophy.
- Percutaneous interventional or other invasive cardiac or peripheral procedure ≤ 14 days or history of previous endocarditis.
- Uncontrolled atrial fibrillation (AF) or is in chronic AF without long term oral anticoagulation.
- Evidence of intracardiac mass, thrombus, or vegetation.
- Hemodynamic instability
- Significant pulmonary disease.
- Nonreactive pulmonary hypertension.
- Chronic steroid use.
- Hypersensitivity or contraindication to anticoagulant or antiplatelet medication.
- Renal insufficiency as evidenced by a serum creatinine > 3.0 or end-stage renal disease requiring chronic dialysis.
- Morbid obesity defined as BMI ≥ 35.
- Subject's iliac arteries have severe calcification, tortuosity, diameter <6mm, or subject has had an aorto-femoral bypass.
- Ongoing infection or sepsis.
- Blood dyscrasias
- Significant aortic disease.
- Pre-existing endovascular stent graft in the supra- or infrarenal aorta or pre-existing stent grafts in the ileo-femoral arteries.
- Active peptic ulcer or has had gastrointestinal (GI) bleeding within the past 3 months (≤ 90 days) prior to the index procedure.
Plan d'étude
Comment l'étude est-elle conçue ?
Détails de conception
- Objectif principal: Traitement
- Répartition: N / A
- Modèle interventionnel: Affectation à un seul groupe
- Masquage: Aucun (étiquette ouverte)
Armes et Interventions
Groupe de participants / Bras |
Intervention / Traitement |
|---|---|
|
Expérimental: Subjects receiving TAVI valve
|
Placement of the SJM TAVI aortic valve with a transfemoral delivery system.
|
Que mesure l'étude ?
Principaux critères de jugement
Mesure des résultats |
Description de la mesure |
Délai |
|---|---|---|
|
Assessment of Technical Feasibility and Device Deployment Characteristics
Délai: At time of procedure
|
Evaluate the technical feasibility and device deployment characteristics (observed at procedure) by:
|
At time of procedure
|
Mesures de résultats secondaires
Mesure des résultats |
Description de la mesure |
Délai |
|---|---|---|
|
Quantification of SAEs Reported (Device Related or Procedure Related)
Délai: Through 12 months post implantation
|
Evaluate the safety of the 23mm SJM Transcatheter Aortic Heart Valve and transfemoral delivery system by:
|
Through 12 months post implantation
|
Collaborateurs et enquêteurs
Parrainer
Les enquêteurs
- Chercheur principal: Ganesh Manoharan, MD, Royal Victoria Hospital
Dates d'enregistrement des études
Dates principales de l'étude
Début de l'étude
Achèvement primaire (Réel)
Achèvement de l'étude (Réel)
Dates d'inscription aux études
Première soumission
Première soumission répondant aux critères de contrôle qualité
Première publication (Estimation)
Mises à jour des dossiers d'étude
Dernière mise à jour publiée (Réel)
Dernière mise à jour soumise répondant aux critères de contrôle qualité
Dernière vérification
Plus d'information
Termes liés à cette étude
Mots clés
Termes MeSH pertinents supplémentaires
Autres numéros d'identification d'étude
- 1103
Ces informations ont été extraites directement du site Web clinicaltrials.gov sans aucune modification. Si vous avez des demandes de modification, de suppression ou de mise à jour des détails de votre étude, veuillez contacter register@clinicaltrials.gov. Dès qu'un changement est mis en œuvre sur clinicaltrials.gov, il sera également mis à jour automatiquement sur notre site Web .