- ICH GCP
- Registro de ensaios clínicos dos EUA
- Ensaio Clínico NCT01487330
First in Human Experience of the St. Jude Medical TAVI Valve and Delivery System (SJM TAVI FIH)
First In Human Experience and Assessment of the 23mm SJM Transcatheter Aortic Valve Implant and the SJM TAVI Transfemoral Delivery System (SJM TAVI FIH)
The purpose of this first-in-human study is to assess the technical feasibility, deployment characteristics, and safety of the 23mm SJM Transfemoral Transcatheter Heart Valve and delivery system in subjects with severe symptomatic aortic stenosis (AS).
This is a single center, prospective, non-randomized, first-in-human investigational study without concurrent or matched controls.
Visão geral do estudo
Status
Condições
Intervenção / Tratamento
Descrição detalhada
Tipo de estudo
Inscrição (Real)
Estágio
- Não aplicável
Contactos e Locais
Locais de estudo
-
-
-
Belfast, Reino Unido
- Royal Victoria Hospital
-
-
Critérios de participação
Critérios de elegibilidade
Idades elegíveis para estudo
Aceita Voluntários Saudáveis
Gêneros Elegíveis para o Estudo
Descrição
Inclusion Criteria:
- Written Informed Consent for participation prior to procedure.
- Legal age in host country.
- Aortic annulus 19-21mm diameter
- Senile degenerative aortic stenosis with derived mean gradient >40mmHg or jet velocity greater than 4.0 m/s or an initial valve area of <1.0 cm2 (or aortic valve area index ≤ 0.6 cm2/m2)
- NYHA Functional Classification of II or greater.
- Predicted operative mortality or serious, irreversible morbidity risk is <50% at 30 days.
- Suitable peripheral vessels and aorta to allow for access of the 18 French delivery system.
Exclusion Criteria:
- History of a cerebral vascular accident (CVA) or transient ischemic attack (TIA) within the past 6 months (≤180 days) of index procedure.
- Carotid artery disease requiring intervention.
- Myocardial infarction (MI) within 6 months (≤180 days) of the index procedure.
- Native aortic valve that is congenitally unicuspid, bicuspid, quadricuspid or non-calcified as seen by echocardiography.
- Mitral or tricuspid valvular regurgitation (grade II) or moderate to severe mitral stenosis.
- Aortic root angulation >70 degrees (horizontal aorta).
- Pre-existing prosthetic valve or prosthetic ring in any position. LVEF < 20%.
- Untreated coronary artery disease (CAD) requiring revascularization.
- Severe basal septal hypertrophy.
- Percutaneous interventional or other invasive cardiac or peripheral procedure ≤ 14 days or history of previous endocarditis.
- Uncontrolled atrial fibrillation (AF) or is in chronic AF without long term oral anticoagulation.
- Evidence of intracardiac mass, thrombus, or vegetation.
- Hemodynamic instability
- Significant pulmonary disease.
- Nonreactive pulmonary hypertension.
- Chronic steroid use.
- Hypersensitivity or contraindication to anticoagulant or antiplatelet medication.
- Renal insufficiency as evidenced by a serum creatinine > 3.0 or end-stage renal disease requiring chronic dialysis.
- Morbid obesity defined as BMI ≥ 35.
- Subject's iliac arteries have severe calcification, tortuosity, diameter <6mm, or subject has had an aorto-femoral bypass.
- Ongoing infection or sepsis.
- Blood dyscrasias
- Significant aortic disease.
- Pre-existing endovascular stent graft in the supra- or infrarenal aorta or pre-existing stent grafts in the ileo-femoral arteries.
- Active peptic ulcer or has had gastrointestinal (GI) bleeding within the past 3 months (≤ 90 days) prior to the index procedure.
Plano de estudo
Como o estudo é projetado?
Detalhes do projeto
- Finalidade Principal: Tratamento
- Alocação: N / D
- Modelo Intervencional: Atribuição de grupo único
- Mascaramento: Nenhum (rótulo aberto)
Armas e Intervenções
Grupo de Participantes / Braço |
Intervenção / Tratamento |
|---|---|
|
Experimental: Subjects receiving TAVI valve
|
Placement of the SJM TAVI aortic valve with a transfemoral delivery system.
|
O que o estudo está medindo?
Medidas de resultados primários
Medida de resultado |
Descrição da medida |
Prazo |
|---|---|---|
|
Assessment of Technical Feasibility and Device Deployment Characteristics
Prazo: At time of procedure
|
Evaluate the technical feasibility and device deployment characteristics (observed at procedure) by:
|
At time of procedure
|
Medidas de resultados secundários
Medida de resultado |
Descrição da medida |
Prazo |
|---|---|---|
|
Quantification of SAEs Reported (Device Related or Procedure Related)
Prazo: Through 12 months post implantation
|
Evaluate the safety of the 23mm SJM Transcatheter Aortic Heart Valve and transfemoral delivery system by:
|
Through 12 months post implantation
|
Colaboradores e Investigadores
Patrocinador
Investigadores
- Investigador principal: Ganesh Manoharan, MD, Royal Victoria Hospital
Datas de registro do estudo
Datas Principais do Estudo
Início do estudo
Conclusão Primária (Real)
Conclusão do estudo (Real)
Datas de inscrição no estudo
Enviado pela primeira vez
Enviado pela primeira vez que atendeu aos critérios de CQ
Primeira postagem (Estimativa)
Atualizações de registro de estudo
Última Atualização Postada (Real)
Última atualização enviada que atendeu aos critérios de controle de qualidade
Última verificação
Mais Informações
Termos relacionados a este estudo
Palavras-chave
Termos MeSH relevantes adicionais
Outros números de identificação do estudo
- 1103
Essas informações foram obtidas diretamente do site clinicaltrials.gov sem nenhuma alteração. Se você tiver alguma solicitação para alterar, remover ou atualizar os detalhes do seu estudo, entre em contato com register@clinicaltrials.gov. Assim que uma alteração for implementada em clinicaltrials.gov, ela também será atualizada automaticamente em nosso site .