Cette page a été traduite automatiquement et l'exactitude de la traduction n'est pas garantie. Veuillez vous référer au version anglaise pour un texte source.

Modified 3d Rectangular Grid Plate for Fixation of Anterior and Body Mandibular Fractures

10 mai 2026 mis à jour par: Alexandria University

Evaluation of the Use of Modified 3d Rectangular Grid Plate for Fixation of Anterior and Body Mandibular Fractures (Randomized Controlled Clinical Trial)

Background: Fractures of anterior mandible (symphysis and parasymphysis) make up about 9% to 57%, of mandibular fractures, and body fractures make up about 21%; posing challenges for stabilization due to anatomical constraints. Traditional 3D plates have limitations in this area, leading to the development of Modified 3D Rectangular Grid plates. Studies have shown that these plates offer superior stabilization over larger configurations while maintaining a low profile like miniplates. Additionally, design modifications ensure mental nerve preservation, balancing effective fixation with neurovascular safety.

Aim of this study: To evaluate the use of Modified 3D Rectangular Grid plates in comparison with conventional mini plates for fixation of mandibular fracture in the anterior and body regions, clinically regarding pain, interfragmentary mobility, maximal inter-incisal opening, wound healing, and sensory nerve evaluation, and radiographically regrading fracture reduction.

Aperçu de l'étude

Type d'étude

Interventionnel

Inscription (Réel)

22

Phase

  • N'est pas applicable

Contacts et emplacements

Cette section fournit les coordonnées de ceux qui mènent l'étude et des informations sur le lieu où cette étude est menée.

Lieux d'étude

    • Azarita
      • Alexandria, Azarita, Egypte, 00203
        • Outpatient Clinic of Oral and Maxillofacial Surgery Department, Faculty of Dentistry, Alexandria University, Egypt

Critères de participation

Les chercheurs recherchent des personnes qui correspondent à une certaine description, appelée critères d'éligibilité. Certains exemples de ces critères sont l'état de santé général d'une personne ou des traitements antérieurs.

Critère d'éligibilité

Âges éligibles pour étudier

  • Adulte

Accepte les volontaires sains

Non

La description

Inclusion Criteria:

  • Patients suffering from recent fractures at the symphysis, parasymphysis and body regions
  • Adult patients with no gender predilection who agreed to present for follow-up visits
  • A fracture that demands open reduction and internal fixation.
  • The patient medically fit for general anesthesia

Exclusion Criteria:

  • Patients suffering from recent fractures at the symphysis, parasymphysis and body regions
  • Adult patients with no gender predilection who agreed to present for follow-up visits
  • A fracture that demands open reduction and internal fixation
  • The patient medically fit for general anesthesia

Plan d'étude

Cette section fournit des détails sur le plan d'étude, y compris la façon dont l'étude est conçue et ce que l'étude mesure.

Comment l'étude est-elle conçue ?

Détails de conception

  • Objectif principal: Traitement
  • Répartition: Randomisé
  • Modèle interventionnel: Affectation parallèle
  • Masquage: Aucun (étiquette ouverte)

Armes et Interventions

Groupe de participants / Bras
Intervention / Traitement
Expérimental: 3D plates
The system consists of a lower 1.5-mm rectangular plate and an upper linear plate that interlock through circular recesses and elevations. Each component is 0.75 mm thick at the junction, giving a total thickness of 1.5 mm. After screw fixation, it provides 3D stability similar to standard 3D plates while minimizing risk to the mental nerve.
Comparateur actif: Conventional plates
conventional mini plates for fixation of mandibular fracture in the anterior and body regions

Que mesure l'étude ?

Principaux critères de jugement

Mesure des résultats
Description de la mesure
Délai
change in maximum mouth opening
Délai: up to 6 weeks
Using a millimetre ruler to measure maximal inter-incisal mouth opening; considered to be adequate if >30 mm and inadequate if <30 mm
up to 6 weeks
change in pain scores
Délai: up to 6 weeks
Will be assessed through a 10-point Visual Analogue Scale (VAS). (0-1= None, 2-4= Mild, 5-7= Moderate, 8-10= Severe
up to 6 weeks

Mesures de résultats secondaires

Mesure des résultats
Description de la mesure
Délai
change in Inter-fragmentary Mobility
Délai: up to 6 weeks
The mobility will be assessed by bi-manual palpation across the fracture site.
up to 6 weeks
change in Wound Evaluation
Délai: up to 6 weeks
The sutured wounds will be examined for signs and symptoms of infection uisng modified Landry's index
up to 6 weeks
adequacy of fracture line reduction
Délai: 6 weeks
Whenever alignment of the inferior border of the mandible will be maintained across the fracture line, it will be considered an excellent reduction. If a discrepancy of 1-3 mm will be noted, it will be considered a good reduction. If a discrepancy of 3-5 mm will be noted, it will be labeled as a fair reduction. If the discrepancy will be > 5 mm, it will be considered a poor reduction.
6 weeks

Collaborateurs et enquêteurs

C'est ici que vous trouverez les personnes et les organisations impliquées dans cette étude.

Dates d'enregistrement des études

Ces dates suivent la progression des dossiers d'étude et des soumissions de résultats sommaires à ClinicalTrials.gov. Les dossiers d'étude et les résultats rapportés sont examinés par la Bibliothèque nationale de médecine (NLM) pour s'assurer qu'ils répondent à des normes de contrôle de qualité spécifiques avant d'être publiés sur le site Web public.

Dates principales de l'étude

Début de l'étude (Réel)

2 mars 2025

Achèvement primaire (Réel)

7 février 2026

Achèvement de l'étude (Réel)

7 février 2026

Dates d'inscription aux études

Première soumission

10 mai 2026

Première soumission répondant aux critères de contrôle qualité

10 mai 2026

Première publication (Réel)

15 mai 2026

Mises à jour des dossiers d'étude

Dernière mise à jour publiée (Réel)

15 mai 2026

Dernière mise à jour soumise répondant aux critères de contrôle qualité

10 mai 2026

Dernière vérification

1 mai 2026

Plus d'information

Termes liés à cette étude

Informations sur les médicaments et les dispositifs, documents d'étude

Étudie un produit pharmaceutique réglementé par la FDA américaine

Non

Étudie un produit d'appareil réglementé par la FDA américaine

Non

Ces informations ont été extraites directement du site Web clinicaltrials.gov sans aucune modification. Si vous avez des demandes de modification, de suppression ou de mise à jour des détails de votre étude, veuillez contacter register@clinicaltrials.gov. Dès qu'un changement est mis en œuvre sur clinicaltrials.gov, il sera également mis à jour automatiquement sur notre site Web .

S'abonner