Modified 3d Rectangular Grid Plate for Fixation of Anterior and Body Mandibular Fractures
Evaluation of the Use of Modified 3d Rectangular Grid Plate for Fixation of Anterior and Body Mandibular Fractures (Randomized Controlled Clinical Trial)
Background: Fractures of anterior mandible (symphysis and parasymphysis) make up about 9% to 57%, of mandibular fractures, and body fractures make up about 21%; posing challenges for stabilization due to anatomical constraints. Traditional 3D plates have limitations in this area, leading to the development of Modified 3D Rectangular Grid plates. Studies have shown that these plates offer superior stabilization over larger configurations while maintaining a low profile like miniplates. Additionally, design modifications ensure mental nerve preservation, balancing effective fixation with neurovascular safety.
Aim of this study: To evaluate the use of Modified 3D Rectangular Grid plates in comparison with conventional mini plates for fixation of mandibular fracture in the anterior and body regions, clinically regarding pain, interfragmentary mobility, maximal inter-incisal opening, wound healing, and sensory nerve evaluation, and radiographically regrading fracture reduction.
Обзор исследования
Статус
Условия
Вмешательство/лечение
Тип исследования
Регистрация (Действительный)
Фаза
- Непригодный
Контакты и местонахождение
Места учебы
-
-
Azarita
-
Alexandria, Azarita, Египет, 00203
- Outpatient Clinic of Oral and Maxillofacial Surgery Department, Faculty of Dentistry, Alexandria University, Egypt
-
-
Критерии участия
Критерии приемлемости
Возраст, подходящий для обучения
- Взрослый
Принимает здоровых добровольцев
Описание
Inclusion Criteria:
- Patients suffering from recent fractures at the symphysis, parasymphysis and body regions
- Adult patients with no gender predilection who agreed to present for follow-up visits
- A fracture that demands open reduction and internal fixation.
- The patient medically fit for general anesthesia
Exclusion Criteria:
- Patients suffering from recent fractures at the symphysis, parasymphysis and body regions
- Adult patients with no gender predilection who agreed to present for follow-up visits
- A fracture that demands open reduction and internal fixation
- The patient medically fit for general anesthesia
Учебный план
Как устроено исследование?
Детали дизайна
- Основная цель: Уход
- Распределение: Рандомизированный
- Интервенционная модель: Параллельное назначение
- Маскировка: Нет (открытая этикетка)
Оружие и интервенции
Группа участников / Армия |
Вмешательство/лечение |
|---|---|
|
Экспериментальный: 3D plates
|
The system consists of a lower 1.5-mm rectangular plate and an upper linear plate that interlock through circular recesses and elevations.
Each component is 0.75 mm thick at the junction, giving a total thickness of 1.5 mm.
After screw fixation, it provides 3D stability similar to standard 3D plates while minimizing risk to the mental nerve.
|
|
Активный компаратор: Conventional plates
|
conventional mini plates for fixation of mandibular fracture in the anterior and body regions
|
Что измеряет исследование?
Первичные показатели результатов
Мера результата |
Мера Описание |
Временное ограничение |
|---|---|---|
|
change in maximum mouth opening
Временное ограничение: up to 6 weeks
|
Using a millimetre ruler to measure maximal inter-incisal mouth opening; considered to be adequate if >30 mm and inadequate if <30 mm
|
up to 6 weeks
|
|
change in pain scores
Временное ограничение: up to 6 weeks
|
Will be assessed through a 10-point Visual Analogue Scale (VAS).
(0-1= None, 2-4= Mild, 5-7= Moderate, 8-10= Severe
|
up to 6 weeks
|
Вторичные показатели результатов
Мера результата |
Мера Описание |
Временное ограничение |
|---|---|---|
|
change in Inter-fragmentary Mobility
Временное ограничение: up to 6 weeks
|
The mobility will be assessed by bi-manual palpation across the fracture site.
|
up to 6 weeks
|
|
change in Wound Evaluation
Временное ограничение: up to 6 weeks
|
The sutured wounds will be examined for signs and symptoms of infection uisng modified Landry's index
|
up to 6 weeks
|
|
adequacy of fracture line reduction
Временное ограничение: 6 weeks
|
Whenever alignment of the inferior border of the mandible will be maintained across the fracture line, it will be considered an excellent reduction.
If a discrepancy of 1-3 mm will be noted, it will be considered a good reduction.
If a discrepancy of 3-5 mm will be noted, it will be labeled as a fair reduction.
If the discrepancy will be > 5 mm, it will be considered a poor reduction.
|
6 weeks
|
Соавторы и исследователи
Спонсор
Даты записи исследования
Изучение основных дат
Начало исследования (Действительный)
Первичное завершение (Действительный)
Завершение исследования (Действительный)
Даты регистрации исследования
Первый отправленный
Впервые представлено, что соответствует критериям контроля качества
Первый опубликованный (Действительный)
Обновления учебных записей
Последнее опубликованное обновление (Действительный)
Последнее отправленное обновление, отвечающее критериям контроля качества
Последняя проверка
Дополнительная информация
Термины, связанные с этим исследованием
Дополнительные соответствующие термины MeSH
Другие идентификационные номера исследования
- 1058-04/2025
Информация о лекарствах и устройствах, исследовательские документы
Изучает лекарственный продукт, регулируемый FDA США.
Изучает продукт устройства, регулируемый Управлением по санитарному надзору за качеством пищевых продуктов и медикаментов США.
Эта информация была получена непосредственно с веб-сайта clinicaltrials.gov без каких-либо изменений. Если у вас есть запросы на изменение, удаление или обновление сведений об исследовании, обращайтесь по адресу register@clinicaltrials.gov. Как только изменение будет реализовано на clinicaltrials.gov, оно будет автоматически обновлено и на нашем веб-сайте. .