Diese Seite wurde automatisch übersetzt und die Genauigkeit der Übersetzung wird nicht garantiert. Bitte wende dich an die englische Version für einen Quelltext.

Modified 3d Rectangular Grid Plate for Fixation of Anterior and Body Mandibular Fractures

10. Mai 2026 aktualisiert von: Alexandria University

Evaluation of the Use of Modified 3d Rectangular Grid Plate for Fixation of Anterior and Body Mandibular Fractures (Randomized Controlled Clinical Trial)

Background: Fractures of anterior mandible (symphysis and parasymphysis) make up about 9% to 57%, of mandibular fractures, and body fractures make up about 21%; posing challenges for stabilization due to anatomical constraints. Traditional 3D plates have limitations in this area, leading to the development of Modified 3D Rectangular Grid plates. Studies have shown that these plates offer superior stabilization over larger configurations while maintaining a low profile like miniplates. Additionally, design modifications ensure mental nerve preservation, balancing effective fixation with neurovascular safety.

Aim of this study: To evaluate the use of Modified 3D Rectangular Grid plates in comparison with conventional mini plates for fixation of mandibular fracture in the anterior and body regions, clinically regarding pain, interfragmentary mobility, maximal inter-incisal opening, wound healing, and sensory nerve evaluation, and radiographically regrading fracture reduction.

Studienübersicht

Studientyp

Interventionell

Einschreibung (Tatsächlich)

22

Phase

  • Unzutreffend

Kontakte und Standorte

Dieser Abschnitt enthält die Kontaktdaten derjenigen, die die Studie durchführen, und Informationen darüber, wo diese Studie durchgeführt wird.

Studienorte

    • Azarita
      • Alexandria, Azarita, Ägypten, 00203
        • Outpatient Clinic of Oral and Maxillofacial Surgery Department, Faculty of Dentistry, Alexandria University, Egypt

Teilnahmekriterien

Forscher suchen nach Personen, die einer bestimmten Beschreibung entsprechen, die als Auswahlkriterien bezeichnet werden. Einige Beispiele für diese Kriterien sind der allgemeine Gesundheitszustand einer Person oder frühere Behandlungen.

Zulassungskriterien

Studienberechtigtes Alter

  • Erwachsene

Akzeptiert gesunde Freiwillige

Nein

Beschreibung

Inclusion Criteria:

  • Patients suffering from recent fractures at the symphysis, parasymphysis and body regions
  • Adult patients with no gender predilection who agreed to present for follow-up visits
  • A fracture that demands open reduction and internal fixation.
  • The patient medically fit for general anesthesia

Exclusion Criteria:

  • Patients suffering from recent fractures at the symphysis, parasymphysis and body regions
  • Adult patients with no gender predilection who agreed to present for follow-up visits
  • A fracture that demands open reduction and internal fixation
  • The patient medically fit for general anesthesia

Studienplan

Dieser Abschnitt enthält Einzelheiten zum Studienplan, einschließlich des Studiendesigns und der Messung der Studieninhalte.

Wie ist die Studie aufgebaut?

Designdetails

  • Hauptzweck: Behandlung
  • Zuteilung: Zufällig
  • Interventionsmodell: Parallele Zuordnung
  • Maskierung: Keine (Offenes Etikett)

Waffen und Interventionen

Teilnehmergruppe / Arm
Intervention / Behandlung
Experimental: 3D plates
The system consists of a lower 1.5-mm rectangular plate and an upper linear plate that interlock through circular recesses and elevations. Each component is 0.75 mm thick at the junction, giving a total thickness of 1.5 mm. After screw fixation, it provides 3D stability similar to standard 3D plates while minimizing risk to the mental nerve.
Aktiver Komparator: Conventional plates
conventional mini plates for fixation of mandibular fracture in the anterior and body regions

Was misst die Studie?

Primäre Ergebnismessungen

Ergebnis Maßnahme
Maßnahmenbeschreibung
Zeitfenster
change in maximum mouth opening
Zeitfenster: up to 6 weeks
Using a millimetre ruler to measure maximal inter-incisal mouth opening; considered to be adequate if >30 mm and inadequate if <30 mm
up to 6 weeks
change in pain scores
Zeitfenster: up to 6 weeks
Will be assessed through a 10-point Visual Analogue Scale (VAS). (0-1= None, 2-4= Mild, 5-7= Moderate, 8-10= Severe
up to 6 weeks

Sekundäre Ergebnismessungen

Ergebnis Maßnahme
Maßnahmenbeschreibung
Zeitfenster
change in Inter-fragmentary Mobility
Zeitfenster: up to 6 weeks
The mobility will be assessed by bi-manual palpation across the fracture site.
up to 6 weeks
change in Wound Evaluation
Zeitfenster: up to 6 weeks
The sutured wounds will be examined for signs and symptoms of infection uisng modified Landry's index
up to 6 weeks
adequacy of fracture line reduction
Zeitfenster: 6 weeks
Whenever alignment of the inferior border of the mandible will be maintained across the fracture line, it will be considered an excellent reduction. If a discrepancy of 1-3 mm will be noted, it will be considered a good reduction. If a discrepancy of 3-5 mm will be noted, it will be labeled as a fair reduction. If the discrepancy will be > 5 mm, it will be considered a poor reduction.
6 weeks

Mitarbeiter und Ermittler

Hier finden Sie Personen und Organisationen, die an dieser Studie beteiligt sind.

Studienaufzeichnungsdaten

Diese Daten verfolgen den Fortschritt der Übermittlung von Studienaufzeichnungen und zusammenfassenden Ergebnissen an ClinicalTrials.gov. Studienaufzeichnungen und gemeldete Ergebnisse werden von der National Library of Medicine (NLM) überprüft, um sicherzustellen, dass sie bestimmten Qualitätskontrollstandards entsprechen, bevor sie auf der öffentlichen Website veröffentlicht werden.

Haupttermine studieren

Studienbeginn (Tatsächlich)

2. März 2025

Primärer Abschluss (Tatsächlich)

7. Februar 2026

Studienabschluss (Tatsächlich)

7. Februar 2026

Studienanmeldedaten

Zuerst eingereicht

10. Mai 2026

Zuerst eingereicht, das die QC-Kriterien erfüllt hat

10. Mai 2026

Zuerst gepostet (Tatsächlich)

15. Mai 2026

Studienaufzeichnungsaktualisierungen

Letztes Update gepostet (Tatsächlich)

15. Mai 2026

Letztes eingereichtes Update, das die QC-Kriterien erfüllt

10. Mai 2026

Zuletzt verifiziert

1. Mai 2026

Mehr Informationen

Begriffe im Zusammenhang mit dieser Studie

Arzneimittel- und Geräteinformationen, Studienunterlagen

Studiert ein von der US-amerikanischen FDA reguliertes Arzneimittelprodukt

Nein

Studiert ein von der US-amerikanischen FDA reguliertes Geräteprodukt

Nein

Diese Informationen wurden ohne Änderungen direkt von der Website clinicaltrials.gov abgerufen. Wenn Sie Ihre Studiendaten ändern, entfernen oder aktualisieren möchten, wenden Sie sich bitte an register@clinicaltrials.gov. Sobald eine Änderung auf clinicaltrials.gov implementiert wird, wird diese automatisch auch auf unserer Website aktualisiert .

Klinische Studien zur Unterkieferfraktur

Klinische Studien zur Modified 3D Rectangular Grid plate

Abonnieren