- ICH GCP
- US-Register für klinische Studien
- Klinische Studie NCT07590401
Modified 3d Rectangular Grid Plate for Fixation of Anterior and Body Mandibular Fractures
Evaluation of the Use of Modified 3d Rectangular Grid Plate for Fixation of Anterior and Body Mandibular Fractures (Randomized Controlled Clinical Trial)
Background: Fractures of anterior mandible (symphysis and parasymphysis) make up about 9% to 57%, of mandibular fractures, and body fractures make up about 21%; posing challenges for stabilization due to anatomical constraints. Traditional 3D plates have limitations in this area, leading to the development of Modified 3D Rectangular Grid plates. Studies have shown that these plates offer superior stabilization over larger configurations while maintaining a low profile like miniplates. Additionally, design modifications ensure mental nerve preservation, balancing effective fixation with neurovascular safety.
Aim of this study: To evaluate the use of Modified 3D Rectangular Grid plates in comparison with conventional mini plates for fixation of mandibular fracture in the anterior and body regions, clinically regarding pain, interfragmentary mobility, maximal inter-incisal opening, wound healing, and sensory nerve evaluation, and radiographically regrading fracture reduction.
Studienübersicht
Status
Bedingungen
Intervention / Behandlung
Studientyp
Einschreibung (Tatsächlich)
Phase
- Unzutreffend
Kontakte und Standorte
Studienorte
-
-
Azarita
-
Alexandria, Azarita, Ägypten, 00203
- Outpatient Clinic of Oral and Maxillofacial Surgery Department, Faculty of Dentistry, Alexandria University, Egypt
-
-
Teilnahmekriterien
Zulassungskriterien
Studienberechtigtes Alter
- Erwachsene
Akzeptiert gesunde Freiwillige
Beschreibung
Inclusion Criteria:
- Patients suffering from recent fractures at the symphysis, parasymphysis and body regions
- Adult patients with no gender predilection who agreed to present for follow-up visits
- A fracture that demands open reduction and internal fixation.
- The patient medically fit for general anesthesia
Exclusion Criteria:
- Patients suffering from recent fractures at the symphysis, parasymphysis and body regions
- Adult patients with no gender predilection who agreed to present for follow-up visits
- A fracture that demands open reduction and internal fixation
- The patient medically fit for general anesthesia
Studienplan
Wie ist die Studie aufgebaut?
Designdetails
- Hauptzweck: Behandlung
- Zuteilung: Zufällig
- Interventionsmodell: Parallele Zuordnung
- Maskierung: Keine (Offenes Etikett)
Waffen und Interventionen
Teilnehmergruppe / Arm |
Intervention / Behandlung |
|---|---|
|
Experimental: 3D plates
|
The system consists of a lower 1.5-mm rectangular plate and an upper linear plate that interlock through circular recesses and elevations.
Each component is 0.75 mm thick at the junction, giving a total thickness of 1.5 mm.
After screw fixation, it provides 3D stability similar to standard 3D plates while minimizing risk to the mental nerve.
|
|
Aktiver Komparator: Conventional plates
|
conventional mini plates for fixation of mandibular fracture in the anterior and body regions
|
Was misst die Studie?
Primäre Ergebnismessungen
Ergebnis Maßnahme |
Maßnahmenbeschreibung |
Zeitfenster |
|---|---|---|
|
change in maximum mouth opening
Zeitfenster: up to 6 weeks
|
Using a millimetre ruler to measure maximal inter-incisal mouth opening; considered to be adequate if >30 mm and inadequate if <30 mm
|
up to 6 weeks
|
|
change in pain scores
Zeitfenster: up to 6 weeks
|
Will be assessed through a 10-point Visual Analogue Scale (VAS).
(0-1= None, 2-4= Mild, 5-7= Moderate, 8-10= Severe
|
up to 6 weeks
|
Sekundäre Ergebnismessungen
Ergebnis Maßnahme |
Maßnahmenbeschreibung |
Zeitfenster |
|---|---|---|
|
change in Inter-fragmentary Mobility
Zeitfenster: up to 6 weeks
|
The mobility will be assessed by bi-manual palpation across the fracture site.
|
up to 6 weeks
|
|
change in Wound Evaluation
Zeitfenster: up to 6 weeks
|
The sutured wounds will be examined for signs and symptoms of infection uisng modified Landry's index
|
up to 6 weeks
|
|
adequacy of fracture line reduction
Zeitfenster: 6 weeks
|
Whenever alignment of the inferior border of the mandible will be maintained across the fracture line, it will be considered an excellent reduction.
If a discrepancy of 1-3 mm will be noted, it will be considered a good reduction.
If a discrepancy of 3-5 mm will be noted, it will be labeled as a fair reduction.
If the discrepancy will be > 5 mm, it will be considered a poor reduction.
|
6 weeks
|
Mitarbeiter und Ermittler
Sponsor
Studienaufzeichnungsdaten
Haupttermine studieren
Studienbeginn (Tatsächlich)
Primärer Abschluss (Tatsächlich)
Studienabschluss (Tatsächlich)
Studienanmeldedaten
Zuerst eingereicht
Zuerst eingereicht, das die QC-Kriterien erfüllt hat
Zuerst gepostet (Tatsächlich)
Studienaufzeichnungsaktualisierungen
Letztes Update gepostet (Tatsächlich)
Letztes eingereichtes Update, das die QC-Kriterien erfüllt
Zuletzt verifiziert
Mehr Informationen
Begriffe im Zusammenhang mit dieser Studie
Zusätzliche relevante MeSH-Bedingungen
Andere Studien-ID-Nummern
- 1058-04/2025
Arzneimittel- und Geräteinformationen, Studienunterlagen
Studiert ein von der US-amerikanischen FDA reguliertes Arzneimittelprodukt
Studiert ein von der US-amerikanischen FDA reguliertes Geräteprodukt
Diese Informationen wurden ohne Änderungen direkt von der Website clinicaltrials.gov abgerufen. Wenn Sie Ihre Studiendaten ändern, entfernen oder aktualisieren möchten, wenden Sie sich bitte an register@clinicaltrials.gov. Sobald eine Änderung auf clinicaltrials.gov implementiert wird, wird diese automatisch auch auf unserer Website aktualisiert .
Klinische Studien zur Unterkieferfraktur
-
Cairo UniversityAbgeschlossenDie Prävalenz des Bifid-Mandibular-KanalsÄgypten
Klinische Studien zur Modified 3D Rectangular Grid plate
-
Madigan Army Medical CenterUnbekanntSchmerzen im unteren Rücken | Myofasziales Schmerzsyndrom im unteren RückenVereinigte Staaten