Questa pagina è stata tradotta automaticamente e l'accuratezza della traduzione non è garantita. Si prega di fare riferimento al Versione inglese per un testo di partenza.

Zip-Stitch™ for Vaginal Cuff Closure in Total Laparoscopic Hysterectomy

31 agosto 2018 aggiornato da: ZSX Medical LLC

Zip-Stitch™ for Vaginal Cuff Closure in Total Laparoscopic Hysterectomy: First in Human Ease of Use Study

ZSX Medical completed enrollment in its First in Human Ease of Use study in May of 2017, in Monterrey Mexico. The purpose of this study is to demonstrate the ease of use of Zip-Stitch™, to generate first in human data, and to refine surgical technique of the device.

Ten subjects were enrolled and received total laparoscopic hysterectomies, including vaginal cuff closure with the Zip-Stitch™ system during their otherwise standard care. Procedures took place over the course of one week. Subjects had in person follow-up appointments at 1 and 6 weeks. Subjects are continuing follow-up through a one-year extension period which will end in May 2018.

Panoramica dello studio

Tipo di studio

Interventistico

Iscrizione (Effettivo)

10

Fase

  • Non applicabile

Contatti e Sedi

Questa sezione fornisce i recapiti di coloro che conducono lo studio e informazioni su dove viene condotto lo studio.

Luoghi di studio

    • Nuevo León
      • Monterrey, Nuevo León, Messico, 64460
        • Hospital Universitario: Universidad Autónoma de Nuevo León de Monterrey

Criteri di partecipazione

I ricercatori cercano persone che corrispondano a una certa descrizione, chiamata criteri di ammissibilità. Alcuni esempi di questi criteri sono le condizioni generali di salute di una persona o trattamenti precedenti.

Criteri di ammissibilità

Età idonea allo studio

18 anni e precedenti (Adulto, Adulto più anziano)

Accetta volontari sani

No

Sessi ammissibili allo studio

Femmina

Descrizione

Inclusion Criteria:

  • Provision of signed and dated Informed Consent Form
  • Stated willingness to comply with all study procedures, including participation in follow-up visits and telephonic follow-up
  • Female, age 18 years or older
  • Indicated for Total Laparoscopic Hysterectomy

Exclusion Criteria:

  • HIV
  • Hepatitis C
  • Diabetics
  • Use of systemic corticosteroids
  • History of pelvic irradiation
  • Active infection
  • History of bleeding problems/hemophilia
  • Cancer
  • Cases in which vaginal cuff closure is intended to be performed robotically
  • Pregnant

Piano di studio

Questa sezione fornisce i dettagli del piano di studio, compreso il modo in cui lo studio è progettato e ciò che lo studio sta misurando.

Come è strutturato lo studio?

Dettagli di progettazione

  • Scopo principale: Fattibilità del dispositivo
  • Assegnazione: N / A
  • Modello interventistico: Assegnazione di gruppo singolo
  • Mascheramento: Nessuno (etichetta aperta)

Armi e interventi

Gruppo di partecipanti / Arm
Intervento / Trattamento
Sperimentale: Single Study Site: UANL
As the only study arm, 10 enrolled subjects received vaginal cuff closure with the Zip-Stitch Soft Tissue Closure System as part of Total Laparoscopic Hysterectomy.
The novel Zip-Stitch System employed a laparoscopic applicator, a series of bio-absorbable clips, and an application procedure to close the vaginal cuff during otherwise standard of care total laparoscopic hysterectomy.

Cosa sta misurando lo studio?

Misure di risultato primarie

Misura del risultato
Misura Descrizione
Lasso di tempo
Device Ease of Use
Lasso di tempo: Immediately following procedure
Ease of Use of the Zip-Stitch Soft Tissue Closure System during Total Laparoscopic Hysterectomy. Assessed following surgery by standardized surgeon interview.
Immediately following procedure

Misure di risultato secondarie

Misura del risultato
Misura Descrizione
Lasso di tempo
Vaginal Cuff Closure
Lasso di tempo: During procedure.
Assessment of quality of vaginal cuff closure following uterine excision. Performed by surgeon as operative standard of care.
During procedure.
Vaginal Cuff Closure Time
Lasso di tempo: During Procedure.
Procedural time from uterine excision to successful vaginal cuff closure.
During Procedure.
Total Surgical Time
Lasso di tempo: During Procedure.
Total procedural time.
During Procedure.
Device Use Learning Curve assessed with a Surgeon Survey
Lasso di tempo: Assessed immediately following study completion during surgeon survey.
Investigation of change in effectiveness of device implementation as assessed by change in efficiency of device use.
Assessed immediately following study completion during surgeon survey.
Sexual Discomfort
Lasso di tempo: Assessed at 1 and 6 week follow-up visits.
Measurement of subject discomfort during sexual activity following completion of surgical procedure. Assessed with 1-10 scale (1 = No Pain, 10 = Most Pain).
Assessed at 1 and 6 week follow-up visits.

Collaboratori e investigatori

Qui è dove troverai le persone e le organizzazioni coinvolte in questo studio.

Sponsor

Investigatori

  • Direttore dello studio: Dan Mazzucco, PhD, ZSX Medical LLC

Studiare le date dei record

Queste date tengono traccia dell'avanzamento della registrazione dello studio e dell'invio dei risultati di sintesi a ClinicalTrials.gov. I record degli studi e i risultati riportati vengono esaminati dalla National Library of Medicine (NLM) per assicurarsi che soddisfino specifici standard di controllo della qualità prima di essere pubblicati sul sito Web pubblico.

Studia le date principali

Inizio studio (Effettivo)

17 aprile 2017

Completamento primario (Effettivo)

30 giugno 2017

Completamento dello studio (Effettivo)

30 maggio 2018

Date di iscrizione allo studio

Primo inviato

26 settembre 2017

Primo inviato che soddisfa i criteri di controllo qualità

13 ottobre 2017

Primo Inserito (Effettivo)

16 ottobre 2017

Aggiornamenti dei record di studio

Ultimo aggiornamento pubblicato (Effettivo)

4 settembre 2018

Ultimo aggiornamento inviato che soddisfa i criteri QC

31 agosto 2018

Ultimo verificato

1 ottobre 2017

Maggiori informazioni

Termini relativi a questo studio

Altri numeri di identificazione dello studio

  • ZHP01-1.0

Informazioni su farmaci e dispositivi, documenti di studio

Studia un prodotto farmaceutico regolamentato dalla FDA degli Stati Uniti

No

Studia un dispositivo regolamentato dalla FDA degli Stati Uniti

prodotto fabbricato ed esportato dagli Stati Uniti

Queste informazioni sono state recuperate direttamente dal sito web clinicaltrials.gov senza alcuna modifica. In caso di richieste di modifica, rimozione o aggiornamento dei dettagli dello studio, contattare register@clinicaltrials.gov. Non appena verrà implementata una modifica su clinicaltrials.gov, questa verrà aggiornata automaticamente anche sul nostro sito web .

Prove cliniche su Isterectomia totale laparoscopica

Sottoscrivi