- ICH GCP
- Registro degli studi clinici negli Stati Uniti
- Sperimentazione clinica NCT07647718
Does a Customized Intubation Facility Reduce Incidence of Difficulty (Person-OTI)
Does a Customized Intubation Facility Reduce Incidence of Difficulty: Randomized Multicenter Trial?
The idea of this study is to demonstrate that the position of the head at a comfort height spontaneously expressed by the patient, between Jackson's amended position or Ramp position, significantly improves the quality of the intubation gesture. This patient position can be easily achieved by placing a compressed air mattress under the patient's trunk - AirPal RAMP ™ mattress.
Thus the investigators can assume that the appropriate positioning and use of a video laryngoscope (McGrathR Mac) places the patient in the best anatomical configuration to breathe and, indirectly to facilitate control of the airways, especially for those with a risk of difficult airway management.
Panoramica dello studio
Stato
Condizioni
Intervento / Trattamento
Descrizione dettagliata
Position for orotracheal intubation The period preceding the administration of anesthetic agents is essential to ensure a satisfactory oxygen supply (pre-oxygenation). Then, once loss of consciousness is achieved, an interface (oral intubation probe) is put in place to allow mechanical ventilation during the procedure. This phase can be marked by a more or less expected difficulty depending on the risk factors presented by the patient. Thus an Arne score> 11 is predictive of a potential difficulty which may lead to an alternative technique being proposed. Simple techniques also exist in the patient setup to reduce the incidence of difficulties. Among them, the placement of a cushion under the head with a slight extension of the head of 20 ° (Jackson's amended position) is recommended because it allows to obtain the alignment of the posterior pharyngeal and glottic spaces. This patient position can be easily achieved by placing a compressed air mattress under the patient's trunk - AirPal RAMP ™ mattress.
This optimization of the position according to the patient, between Jackson's amended position or Ramp position, opens up the prospect of defining an optimal position personalized to each patient. Thus, it can be assumed that the appropriate positioning places the patient in the best anatomical configuration for breathing and, indirectly, to facilitate control of the airways.
- Video laryngoscope The use of a video laryngoscope (McGrathR Mac) is becoming widespread in anesthesia, especially for the management of patients at risk of difficult airway management. This device by the video support at the end of the blade provides a better visualization of the glottic orifice.
- The hypothesis of this research The idea of this study is to demonstrate that the position of the head at a height of comfort spontaneously expressed by the patient significantly improves the quality of the intubation procedure.
Tipo di studio
Fase
- Non applicabile
Contatti e Sedi
Luoghi di studio
-
-
-
Suresnes, Francia, 92150
- Morgan LE GUEN, PhD
-
-
Criteri di partecipazione
Criteri di ammissibilità
Età idonea allo studio
- Adulto
- Adulto più anziano
Accetta volontari sani
Descrizione
Inclusion Criteria:
- Men or women over 18 and under 80;
- Must undergo general anesthesia with oral intubation using a standard intubation probe;
- Can be contacted directly by telephone if they are patients treated in outpatient surgery;
- Having signed a consent form;
- Being affiliated to a Health Insurance scheme.
Exclusion Criteria:
- pregnant or breastfeeding patients;
- patients with a predicted difficulty in mask ventilation or intubation according to the assessment of the doctor who performs the clinical examination prior to inclusion (Arne score ≥ 11) or the one who takes care of the patient in the block operative;
- patients for whom the surgery requires the placement of a double-lumen tube;
- patients requiring rapid sequence induction;
- patients for whom induction cannot be carried out by the sufentanil, propofol, atracurium or rocuronium sequence.
Piano di studio
Come è strutturato lo studio?
Dettagli di progettazione
- Scopo principale: Altro
- Assegnazione: Randomizzato
- Modello interventistico: Assegnazione parallela
- Mascheramento: Nessuno (etichetta aperta)
Armi e interventi
Gruppo di partecipanti / Arm |
Intervento / Trattamento |
|---|---|
|
Sperimentale: Custom
patient with installation on an infused airbag until a comfortable position is reached
|
patient with personalized installation until a comfortable position is reached
|
|
Nessun intervento: Control
Jackson's amended position with placement of a 6 cm high cushion under the patient's head
|
Cosa sta misurando lo studio?
Misure di risultato primarie
Misura del risultato |
Misura Descrizione |
Lasso di tempo |
|---|---|---|
|
the impact of a custom installation versus a conventional Jackson amended installation with a 6-centimeter cushion under the patient's head to facilitate orotracheal intubation
Lasso di tempo: 1 day
|
the proportion of orotracheal intubations for which third party assistance is required
|
1 day
|
Misure di risultato secondarie
Misura del risultato |
Misura Descrizione |
Lasso di tempo |
|---|---|---|
|
Assessment of the effect of patient positioning on the quality of exposure during intubation
Lasso di tempo: 1 day
|
|
1 day
|
|
Determination of the most frequent complementary resettlement actions
Lasso di tempo: 1 day
|
|
1 day
|
|
Assessment of the quality of manual ventilation before intubation (peroxygenation)
Lasso di tempo: 1 day
|
|
1 day
|
|
Assessment of the frequency and severity of complications of intubation
Lasso di tempo: 2 days
|
The complications of intubation was defined by the pharyngeal pain the day after surgery, dysphonia, an irritative cough reported by the patient and atelectasis.
|
2 days
|
|
Assessment of patient comfort and the doctor's opinion on the technique
Lasso di tempo: 1 day
|
The doctor's opinion on the technique was defined by the regard to pre-oxygenation, peroxygenation, and intubation.
|
1 day
|
|
Safety assessment of the technique
Lasso di tempo: 1 day
|
Safety was evaluated by the occurrence of a fall of the head, occurrence of a fall of the patient, accidental extubation, the incidence of arterial oxygen desaturation, the lowest arterial oxygen saturation and the perception of difficulty in intubation.
|
1 day
|
Collaboratori e investigatori
Sponsor
Studiare le date dei record
Studia le date principali
Inizio studio (Effettivo)
Completamento primario (Effettivo)
Completamento dello studio (Effettivo)
Date di iscrizione allo studio
Primo inviato
Primo inviato che soddisfa i criteri di controllo qualità
Primo Inserito (Effettivo)
Aggiornamenti dei record di studio
Ultimo aggiornamento pubblicato (Effettivo)
Ultimo aggiornamento inviato che soddisfa i criteri QC
Ultimo verificato
Maggiori informazioni
Termini relativi a questo studio
Parole chiave
Altri numeri di identificazione dello studio
- 2020_0030
Piano per i dati dei singoli partecipanti (IPD)
Hai intenzione di condividere i dati dei singoli partecipanti (IPD)?
Informazioni su farmaci e dispositivi, documenti di studio
Studia un prodotto farmaceutico regolamentato dalla FDA degli Stati Uniti
Studia un dispositivo regolamentato dalla FDA degli Stati Uniti
Queste informazioni sono state recuperate direttamente dal sito web clinicaltrials.gov senza alcuna modifica. In caso di richieste di modifica, rimozione o aggiornamento dei dettagli dello studio, contattare register@clinicaltrials.gov. Non appena verrà implementata una modifica su clinicaltrials.gov, questa verrà aggiornata automaticamente anche sul nostro sito web .