このページは自動翻訳されたものであり、翻訳の正確性は保証されていません。を参照してください。 英語版 ソーステキスト用。

Pacing for Heart Failure With Preserved Ejection Fraction (HFpEF)

2013年5月29日 更新者:Medtronic Cardiac Rhythm and Heart Failure
The purpose of this research study is to evaluate the safety of a new pacing method (Fusion Pacing) for heart failure patients with an ejection fraction (EF) greater than 50% over a period of 4 months, and determine the effects on different measures of heart failure. This new pacing method may allow the heart to pump more efficiently. Participation in this study will last approximately 8 months.

調査の概要

状態

完了

条件

介入・治療

詳細な説明

Patients with an EF greater than 50% and a regional mechanical delay of >= 65ms (an indication of mechanical dyssynchrony) will receive an implantable cardioverter defibrillator (ICD) with a special pacing feature. When the feature is active, the device wil pace the left ventricle to target improved pump efficiency. Patients will have the feature active for 4 months and inactive for 4 months. The order will be randomized and the patient will not know whether the pacing is active or not. Echocardiography, biomarkers, exercise testing, quality of life (QOL) testing and device information will be used to compare the patient's status while the feature is active vs. inactive.

研究の種類

介入

入学 (実際)

22

段階

  • 適用できない

連絡先と場所

このセクションには、調査を実施する担当者の連絡先の詳細と、この調査が実施されている場所に関する情報が記載されています。

研究場所

      • Aalst、ベルギー
      • Taipei、台湾
        • National Taiwan University Hospital

参加基準

研究者は、適格基準と呼ばれる特定の説明に適合する人を探します。これらの基準のいくつかの例は、人の一般的な健康状態または以前の治療です。

適格基準

就学可能な年齢

18年歳以上 (大人、高齢者)

健康ボランティアの受け入れ

いいえ

受講資格のある性別

全て

説明

Inclusion Criteria:

  • Patients with quantitative ejection fraction (EF) of greater than 50 percent
  • Patients with active heart failure (symptomatic American Heart Association/American College of Cardiology stage C) despite optimal medications
  • Patients greater than 18 years of age
  • Patients willing and able to give informed consent
  • Patients available for appropriate follow-up times for the length of study
  • Patients able to complete cardiopulmonary exercise (CPX) testing
  • Patients expected lifespan is greater than 12 months beyond study enrollment
  • Patients with a regional mechanical delay (RMD) (septal-lateral) greater than 65 milliseconds

Exclusion Criteria:

  • Patients who have undergone cardiac surgery 60 days prior to enrollment
  • Patients who have had a myocardial infarction 90 days prior to enrollment
  • Patients with hemodynamically significant uncorrected cardiac valvular disease
  • Patients with active myocarditis and amyloidosis (if documented)
  • Patients with a permanent pacemaker
  • Patients with creatinine greater than 2 milligrams per milliliter or estimated glomerular filtration rate (eGFR) less than 30 to 50 milliliters per hour
  • Patients with permanent or chronic sustained atrial fibrillation (fibrillation lasting 7 days or more at a time)
  • Patients with a PR interval greater than 250 milliseconds
  • Patients with severe chronic obstructive pulmonary disease
  • Patients with high risk coronary artery disease
  • Patients who are or expect to become pregnant during this study
  • Patients enrolled in concurrent studies which could confound the results of this study
  • Patients with hypertrophic cardiomyopathy (obstructive or non-obstructive)
  • Patients with infiltrative disease or restrictive cardiomyopathy
  • Patients with indication for percutaneous coronary intervention (PCI) at enrollment

研究計画

このセクションでは、研究がどのように設計され、研究が何を測定しているかなど、研究計画の詳細を提供します。

研究はどのように設計されていますか?

デザインの詳細

  • 主な目的:処理
  • 割り当て:ランダム化
  • 介入モデル:クロスオーバー割り当て
  • マスキング:独身

武器と介入

参加者グループ / アーム
介入・治療
アクティブコンパレータ:Fusion Pacing OFF
Subjects initially randomized to the Fusion Pacing OFF Arm will receive the Fusion Pacing software download at the implant visit, but the Fusion Pacing software will be programmed OFF. At 4 months subjects in this arm will crossover to the Fusion Pacing ON Arm.
Market approved InSync Sentry™ model 7298, dual chamber Implantable Cardioverter Defibrillator (ICD) with Cardiac Resynchronization Therapy (CRT) including sequential biventricular pacing and OptiVol® fluid monitoring or market approved InSync Maximo™ model 7304 dual chamber ICD with CRT including sequential biventricular pacing.
他の名前:
  • Fusion Pacing Investigational Software
  • Fusion Pacing is an algorithm that is downloaded for use in InSync Sentry™ or InSync Maximo™ devices.
実験的:Fusion Pacing ON
Subjects initially randomized to the Fusion Pacing ON Arm will receive the Fusion Pacing software download at the implant visit, and the Fusion Pacing software will be programmed ON. At 4 months subjects in this arm will crossover to the Fusion Pacing OFF Arm.
Market approved InSync Sentry™ model 7298, dual chamber Implantable Cardioverter Defibrillator (ICD) with Cardiac Resynchronization Therapy (CRT) including sequential biventricular pacing and OptiVol® fluid monitoring or market approved InSync Maximo™ model 7304 dual chamber ICD with CRT including sequential biventricular pacing.
他の名前:
  • Fusion Pacing Investigational Software
  • Fusion Pacing is an algorithm that is downloaded for use in InSync Sentry™ or InSync Maximo™ devices.

この研究は何を測定していますか?

主要な結果の測定

結果測定
時間枠
Number of adverse events while the Fusion Pacing download is active vs. inactive.
時間枠:From baseline to 4-month follow-up visit, and 4-month follow-up visit to 8-month follow-up visit
From baseline to 4-month follow-up visit, and 4-month follow-up visit to 8-month follow-up visit
Percentage of time the Fusion Pacing is active throughout a four-month follow-up period.
時間枠:From baseline to 4-month follow-up visit, and 4-month follow-up visit to 8-month follow-up visit
From baseline to 4-month follow-up visit, and 4-month follow-up visit to 8-month follow-up visit

二次結果の測定

結果測定
時間枠
Change in Minnesota Living with Heart Failure Questionnaire score.
時間枠:From baseline to 4-month follow-up visit, and 4-month follow-up visit to 8-month follow-up visit
From baseline to 4-month follow-up visit, and 4-month follow-up visit to 8-month follow-up visit
Change in peak VO2 during Cardio-pulmonary Exercise Testing (CPX).
時間枠:From baseline to 4-month follow-up visit, and 4-month follow-up visit to 8-month follow-up visit
From baseline to 4-month follow-up visit, and 4-month follow-up visit to 8-month follow-up visit
Change in echocardiography measures: E/E', Ejection Fraction, LV EDV.
時間枠:From baseline to 4-month follow-up visit, and 4-month follow-up visit to 8-month follow-up visit
From baseline to 4-month follow-up visit, and 4-month follow-up visit to 8-month follow-up visit
Change in NT-proBNP.
時間枠:From baseline to 4-month follow-up visit, and 4-month follow-up visit to 8-month follow-up visit
From baseline to 4-month follow-up visit, and 4-month follow-up visit to 8-month follow-up visit

協力者と研究者

ここでは、この調査に関係する人々や組織を見つけることができます。

スポンサー

捜査官

  • スタディチェア:HFpEF Trial Leader、Medtronic

研究記録日

これらの日付は、ClinicalTrials.gov への研究記録と要約結果の提出の進捗状況を追跡します。研究記録と報告された結果は、国立医学図書館 (NLM) によって審査され、公開 Web サイトに掲載される前に、特定の品質管理基準を満たしていることが確認されます。

主要日程の研究

研究開始

2010年6月1日

一次修了 (実際)

2013年1月1日

研究の完了 (実際)

2013年1月1日

試験登録日

最初に提出

2010年1月8日

QC基準を満たした最初の提出物

2010年1月8日

最初の投稿 (見積もり)

2010年1月11日

学習記録の更新

投稿された最後の更新 (見積もり)

2013年5月30日

QC基準を満たした最後の更新が送信されました

2013年5月29日

最終確認日

2013年5月1日

詳しくは

本研究に関する用語

追加の関連 MeSH 用語

その他の研究ID番号

  • MDT0095101

この情報は、Web サイト clinicaltrials.gov から変更なしで直接取得したものです。研究の詳細を変更、削除、または更新するリクエストがある場合は、register@clinicaltrials.gov。 までご連絡ください。 clinicaltrials.gov に変更が加えられるとすぐに、ウェブサイトでも自動的に更新されます。