このページは自動翻訳されたものであり、翻訳の正確性は保証されていません。を参照してください。 英語版 ソーステキスト用。

口が正常に開いている患者における直接喉頭鏡検査中のマッキントッシュ喉頭鏡ブレードの機能的寸法の評価

2026年11月11日 更新者:Nitin Sethi, DNB、Sir Ganga Ram Hospital

正常に開口している患者における喉頭鏡検査中のマッキントッシュ ブレードの機能的寸法の評価: 粘膜下線維症による開口制限の症例における喉頭鏡検査の促進のための実現可能性モデルの開発

Direct laryngoscopy and intubation is an essential initial aspect of airway access during general anesthesia. To perform the procedure effectively, it requires adequate mouth opening, head and neck movement, and a normal temporo-mandibular joint mobility. Any issue with the above three results in a compromised upper airway at the outset and the condition is known as anticipated difficult airway, i.e. an airway that is difficult to access with conventional laryngoscopy and intubation methods. To overcome the difficulty, either one has to resort to newer advanced technique and equipment or the available conventional technique needs to be refined and modified to suit the requirement. While the former requires extraordinary expertise and finances, an option difficult to achieve in developing countries; the latter warrants focused interest to develop alternative approach with the same set of equipments.

Since submucous fibrosis and the associated restricted mouth opening have taken the proposition of an epidemic owing to widespread use of betel nut and tobacco; these patients, when requiring surgery, are difficult candidates for GA and airway control. The fact that, when they arrive as pre-surgical candidates, they have variable degree of mouth opening restriction, which if approached with a strategy, may be amenable to conventional control of airway. If investigators paint all the patients with mouth restriction as difficult airway, it will result in uncalled surgical, economic, health system and psychological burden. Therefore, it is prudent to undertake research relating to refinement of airway access techniques with the easily available, cheap and user- friendly equipment (conventional laryngoscope), such that a proportion of above stated burden can be reduced.

In view of the above, investigators plan to undertake a study to enhance our working knowledge with a conventional laryngoscope (Macintosh) to facilitate ways to control the airway difficulty secondary to mouth opening restriction. Investigators believe that the prospective knowledge thus generated would help us identify whether there is a feasibility of conventional airway management or an alternative advanced access technique is needed in the first place. This will prevent undue cancellations, delayed surgeries, and patient morbidity.

調査の概要

状態

一時停止

条件

介入・治療

詳細な説明

Upper airway access is one of the essential components of general anaesthesia, and more often than not, it is gained by direct laryngoscopy followed by tracheal intubation. While direct laryngoscopy depends on laryngoscope blade design and the anesthetists' skill set, the ease of tracheal intubation is influenced by the line-of-view to the glottis gained by the laryngoscopy maneuver. In patients with normal mouth opening (≥4.0 cm), the act of conventional airway access is not difficult given that the neck extension and the TMJ joint mobility is within normal limits. Conversely, it becomes difficult in patients who have mouth opening restriction, and hence they are adjudicated as 'anticipated difficult airway' (ADA). The ADA, attracts several issues that, not uncommonly, converges on to time inefficiency, heightened equipment cost, operator anxiety, and unfortunately, patient morbidity. There are many causes of restricted mouth opening, defined technically as reduced inter-incisor distance (IID) including trauma, TMJ movement limitation, intra/extra-oral pathology resulting in pain, or the most common pathology in the Indian subcontinent, oral submucosal fibrosis (SMF). While the pathology itself is a forerunner of oral mitosis, it is the associated restricted mouth opening component that put conventional airway access efforts of the anaesthesiologist in spot, and consequently, a whole, sometimes unnecessary rigmarole has to be activated under the heading of 'advanced approach to ADA'.

Oral submucous fibrosis (SMF) is a well-recognized, potentially malignant progressive condition afflicting the oral cavity that is characterised by a reduced mouth opening. The reduction in mouth opening occurs due a vertical reorientation of collagen fibrils that are normally haphazardly arranged. Of the currently available multiple classifications to identify disease stage/severity, the functional classification based on the inter-incisor distance (IID) seems to be most relevant.

IID forms an important component of airway examination and a value of less than 3-cm is suggestive of difficulty in airway management. However, despite the above, SMF is largely unrecognized as a cause of airway difficulty, and even when recognized, no set protocol is available to ensure (as far as possible) a favourable outcome in terms of least morbidity to the patient, and stress to the anaesthesiology team in question.

Need Assessment for the Study Generally, in a tertiary level centre, with all facilities at hand, cases with a reduced IID are normally tackled using a fiberoptic bronchoscope guided tracheal intubation. However, in India, the burden of this disease lies to a great extent in rural/suburban settings where access to a fiberoptic bronchoscope is unlikely. As a result these cases are referred to 'higher' centres for management. This imposes undue burden (logistics/ financial) onto patients and their families. Hence, there is a great need for anaesthesiologists working at the primary/secondary level healthcare set up to get oriented to this problem and be able to manage it with conventional options (direct laryngoscopy & intubation) available to them.

Scientific Contention Direct laryngoscopy remains the foremost among the various techniques available to access the upper airway and the Macintosh blade has been the most preferred blade type. In order to improve direct laryngoscopy, many modifications of blade design have been tested/ compared with the Macintosh blade, but apparently, the clarity as to which laryngoscope blade is most suited for a given airway remains low. For the majority of practicing anaesthesiologists, the availability of different laryngoscope designs has only increased the hit-and-trial option for laryngoscopy.

Since the time it was first introduced, the Macintosh blade (size 1, 2, 3, 4, and 5) has weathered many newer laryngoscope blade designs and stood by our side with consistent/optimal performance. Per se, from a technical standpoint, although shaped the same, various sizes of the Macintosh blade are not exactly similar, the discrepancy becomes obvious when comparing sizes 1, 2 with 3 & 4. Unfortunately, investigators are still unclear as to how design characteristics and the various sizes of the Macintosh blade impact the process of direct laryngoscopy. Generally, the selection of laryngoscope blade (type and sizes) is largely a function of individual experience and preferences. The absence of predefined parameters for the selection of the most appropriate laryngoscope blade for a given airway remains arbitrary. Apparently, an anaesthesiologist will be able to intubate an adult trachea with any of the laryngoscope blade, however, blade type and size selection assumes significance in the presence of a difficult airway.

The three factors which influence successful direct laryngoscopy performance are:

i) The ability to place the laryngoscope blade tip in vallecular recess and engage the hyoid bone. This requires an adequate length of the blade to be introduced orally to reach the vallecula (transition space between base of the tongue and the epiglottis) position.

ii) The ability to displace the tongue aside for clear view to the glottic-epiglottic region iii) Achieving a clear line-of-sight to the glottis-opening. To ensure that the tip of the laryngoscope blade engages the hyoid by placement in the vallecula, an adequate blade length must be inserted into the oral cavity. Normally, this is easily achieved. However, when faced with a situation involving reduced mouth opening/inter-incisor distance (e.g.as in case of SMF), the length of blade that can be inserted into the oral cavity (functional length) becomes a function of the width of the blade's flange at the incisor point. Thus the size of the flange, corresponding to the width of the blade that must be accommodated in the oral cavity assumes particular significance in patients with reduced inter-incisor gap. Typically, for the Macintosh blade's curved design confers different length to its flange's glossal (concave) and the palatal (convex) surface, the functional width of its flange increases from the tip towards the heel [Figure]. Based on the degree of mouth opening restriction and the available IID (in cm), during preoperative evaluation, one can predict and plan how long a Macintosh blade length will be required and what size of the blade would suffice to be placed orally through the available IID.

Hypothesis Development Marks et al, utilized an x-ray based method to devise a method to evaluate laryngoscope blade design during active laryngoscopy procedure. Technically, they found that Macintosh sizes 3 and 4 have a more refined blade design that provides greater degree of forward space enhancement (FSE, allows greater mandibular space for the tongue to be moved into) than other conventional blades (Miller, Soper, etc.). This FSE-effect gets further magnified with increase in functional length of the blade (the length of the blade inside the oral cavity during active laryngoscopy).

Their elaborate work addressed the performance of the laryngoscope blade (size, type) selection in a theoretical setting. The information gleaned from their assessment offered valuable suggestions on optimal blade position during direct laryngoscopy and included:

i) Mandibular space 'encroachment/enhancement' with the use of different blade types/sizes, and ii) 'Line-of-vision' (view to the glottis) versus 'mandibular space restriction' (space for tongue displacement during laryngoscopy).

However, still, the clinical feasibility of knowledge thus gained from performance assessment facilitated by x-ray/fluoroscopy is difficult to translate into routine clinical practice.

As the investigator prepares to take the conventional direct laryngoscopy process into difficult airway situations where the primary difficulty is due to reduced mouth opening, there is a need to convert theoretical knowledge into clinical suggestions. Investigators thus contend that unless they get accustomed with greater clarity on the use of routine equipments, and analyse their practical feasibility in difficult situations, the element of randomness and subjectivity will continue to be a setback.

研究の種類

観察的

入学 (推定)

100

連絡先と場所

このセクションには、調査を実施する担当者の連絡先の詳細と、この調査が実施されている場所に関する情報が記載されています。

研究場所

      • New Delhi、インド、110060
        • Sir Ganga Ram Hospital

参加基準

研究者は、適格基準と呼ばれる特定の説明に適合する人を探します。これらの基準のいくつかの例は、人の一般的な健康状態または以前の治療です。

適格基準

就学可能な年齢

20年~65年 (大人、高齢者)

健康ボランティアの受け入れ

いいえ

受講資格のある性別

全て

サンプリング方法

非確率サンプル

調査対象母集団

Patients scheduled for surgery under general anaesthesia with airway control by direct laryngoscopy and tracheal intubation

説明

Inclusion Criteria:

  1. Consenting adults
  2. Both gender
  3. Age: 20-65 years
  4. Normal preoperative upper airway evaluation and without the presence of anticipated airway access difficulty
  5. Patients scheduled for surgery under general anaesthesia with airway control by direct laryngoscopy and tracheal intubation

Exclusion Criteria:

  1. Patient refusal
  2. Anticipated airway access difficulty
  3. Edentulous patients
  4. Patients with dental problem (missing tooth, overlap, cosmetic treatment)
  5. Vulnerable Patients: High risk situation, major surgery, extremes of age, obstetric patients
  6. Previously difficult airway

研究計画

このセクションでは、研究がどのように設計され、研究が何を測定しているかなど、研究計画の詳細を提供します。

研究はどのように設計されていますか?

デザインの詳細

  • 観測モデル:COHORT
  • 時間の展望:PROSPECTIVE

この研究は何を測定していますか?

主要な結果の測定

結果測定
メジャーの説明
時間枠
Macintosh Blade Length Measurement (in centimeters)
時間枠:0 to 5-minutes

Length of Macintosh blade size 3 and 4 as such (static) and during active direct laryngoscopy (active).

0 to 5-minutes
Macintosh Blade Width Measurement (in centimeters)
時間枠:0 to 5-minutes

Width of Macintosh blade size 3 and 4 as such (static) and during active direct laryngoscopy (active).

0 to 5-minutes
Inter-incisor Angle on Macintosh Blade Contact Point (in degrees)
時間枠:0 to 5-minutes

The angle formed by the line between the two contact points, viz. a point formed by upper incisor contact of upper flange curve (convex) of the Macintosh laryngoscope blade, and a point of contact between the lower incisor contact with lower flange curve (concave curve) of the Macintosh laryngoscope blade. The line formed by joining these two contact points with the baseline of the laryngoscope will form an angle. This angle will be noted as functional separation of eugnathic, retrognathic or prognathic maxilo-mandibular orientation

0 to 5-minutes

二次結果の測定

結果測定
メジャーの説明
時間枠
Upper Airway Measurements (in centimeters)
時間枠:0 to 5-minutes

Mento-hyoid, mento-thyroid distance, and the length of sub-mandibular triangle perpendicular

0 to 5-minutes
Correlation Assessment
時間枠:0 to 5-minutes

The functional laryngoscope length will be tested for correlation with the linear neck (Mento-hyoid distance, menlo-thyroid distance ) and mandibular distances (perpendicular to sub-mandibular triangle) and the most consistent one will be taken

0 to 5-minutes

協力者と研究者

ここでは、この調査に関係する人々や組織を見つけることができます。

スポンサー

捜査官

  • スタディディレクター:Amitabh Dutta, MD、Sir Ganga Ram Hospital, New Delhi, INDIA
  • スタディチェア:Ameya Pappu, MBBS、Sir Ganga Ram Hospital, New Delhi, INDIA
  • 主任研究者:Nitin Sethi, DNB、Sir Ganga Ram Hospital, New Delhi, INDIA

研究記録日

これらの日付は、ClinicalTrials.gov への研究記録と要約結果の提出の進捗状況を追跡します。研究記録と報告された結果は、国立医学図書館 (NLM) によって審査され、公開 Web サイトに掲載される前に、特定の品質管理基準を満たしていることが確認されます。

主要日程の研究

研究開始 (推定)

2028年10月1日

一次修了 (推定)

2030年6月1日

研究の完了 (推定)

2030年7月1日

試験登録日

最初に提出

2015年12月13日

QC基準を満たした最初の提出物

2015年12月21日

最初の投稿 (推定)

2015年12月28日

学習記録の更新

投稿された最後の更新 (実際)

2026年11月16日

QC基準を満たした最後の更新が送信されました

2026年11月11日

最終確認日

2026年11月1日

詳しくは

本研究に関する用語

その他の研究ID番号

  • EC/10/15/901

この情報は、Web サイト clinicaltrials.gov から変更なしで直接取得したものです。研究の詳細を変更、削除、または更新するリクエストがある場合は、register@clinicaltrials.gov。 までご連絡ください。 clinicaltrials.gov に変更が加えられるとすぐに、ウェブサイトでも自動的に更新されます。