A Difference in Subclavian Vein Catheterization Between Supine and Lateral Tilt Position - Stage I
A Difference in the Cross-section Area of Subclavian Vein Between Supine and Lateral Tilt Position: Its Clinical Impact on Subclavian Venous Catheterization - Stage II
Central venous catheterization is widely used for various purposes during surgery. For central venous catheterization, subclavian vein is selected because of the relatively low risk of infection, long-term patency and low patient discomfort. The cross - sectional area of the subclavian vein is an important factor to increase success rate. Several studies have reported that the Trendelenburg position increases the cross-sectional area of the subclavian vein, and the lateral tilt position can change the cross-sectional area of the subclavian vein. However, the impact of lateral tilt position to the cross-sectional area of the subclavian vein is not clear. The ipsilateral position can increase the cross-sectional area of the subclavian vein, and the contralateral position can decrease the cross-sectional area by gravity.
In the first stage of this study, we compare the cross-sectional area of subclavian vein using ultrasonography in supine, ipsilateral, and contralateral tilt position.
調査の概要
状態
状態
条件
条件
介入・治療
介入・治療
研究の種類
研究の種類
入学 (予想される)
入学
段階
段階
- 適用できない
参加基準
適格基準
適格基準
就学可能な年齢
健康ボランティアの受け入れ
受講資格のある性別
説明
Inclusion Criteria:
- the patients who receive elective neurosurgical surgery and require central venous catheter
Exclusion Criteria:
- the patients who have puncture site infection
- the patients who have chemoport, pacemaker in right subclavian vein
- the patients who had received right mastectomy or right pneumonectomy
- other contraindications for subclavian venous catheterization (eg. mass, hematoma, vegetation, and anticoagulation)
研究計画
研究はどのように設計されていますか?
デザインの詳細
- 主な目的:診断
- 割り当て:ランダム化
- 介入モデル:クロスオーバー割り当て
- マスキング:なし(オープンラベル)
アーム数
武器と介入
参加者グループ / アーム参加者グループ / アーム |
介入・治療介入・治療 |
|---|---|
|
実験的:Ipsilateral tilt
Measuring the cross-sectional area of right subclavian vein in the 20 degree left tilting posture.
|
手術台は右横に20度傾けます。
|
|
介入なし:Supine
Measuring the cross-sectional area of right subclavian vein in supine position.
|
|
|
アクティブコンパレータ:Contralateral tilt
Measuring the cross-sectional area of right subclavian vein in the 20 degree left tilting posture.
|
The operation table will be tilted 20 degrees left laterally.
|
この研究は何を測定していますか?
主要な結果の測定
主要な結果の測定
結果測定 |
メジャーの説明 |
時間枠 |
|---|---|---|
|
The cross-sectional area of right subclavian vein
時間枠:1 minutes after position change
|
The cross-sectional area of right subclavian vein
|
1 minutes after position change
|
協力者と研究者
出版物と役立つリンク
一般刊行物
- Yoon HK, Lee HC, Kang P, Lee JM, Park HP, Cho YJ. Effects of ipsilateral tilt position on the cross-sectional area of the subclavian vein and the clinical performance of subclavian vein catheterization: a prospective randomized trial. BMC Anesthesiol. 2020 Sep 5;20(1):226. doi: 10.1186/s12871-020-01144-1.
- Jung DE, Lee HC, Yoon HK, Park HP. The effects of ipsilateral tilt position on right subclavian venous catheterization: study protocol for a prospective randomized trial. Trials. 2018 May 24;19(1):292. doi: 10.1186/s13063-018-2666-8.
研究記録日
主要日程の研究
研究開始 (予想される)
研究開始
一次修了 (予想される)
一次修了
研究の完了 (予想される)
研究の完了
試験登録日
最初に提出
最初に提出
QC基準を満たした最初の提出物
QC基準を満たした最初の提出物
最初の投稿 (実際)
最初の投稿
学習記録の更新
投稿された最後の更新 (実際)
投稿された最後の更新
QC基準を満たした最後の更新が送信されました
QC基準を満たした最後の更新が送信されました
最終確認日
最終確認日
詳しくは
本研究に関する用語
その他の研究ID番号
その他の研究ID番号
- 2017-110-871-1
医薬品およびデバイス情報、研究文書
米国FDA規制医薬品の研究
米国FDA規制機器製品の研究
この情報は、Web サイト clinicaltrials.gov から変更なしで直接取得したものです。研究の詳細を変更、削除、または更新するリクエストがある場合は、register@clinicaltrials.gov。 までご連絡ください。 clinicaltrials.gov に変更が加えられるとすぐに、ウェブサイトでも自動的に更新されます。
同側傾斜の臨床試験
-
NCT05222932積極的、募集していないメラノーマ | 頭頸部扁平上皮がん
-
NCT05271318積極的、募集していないプラチナ耐性卵巣がん | プラチナ耐性卵管がん | プラチナ耐性原発性腹膜癌 | プラチナ難治性卵管がん | プラチナ難治性原発性腹膜癌 | プラチナ抵抗性卵巣癌 | -参加者がカルボプラチンおよび/またはシスプラチンに対するアレルギーまたは重度の不耐性を有するプラチナ感受性卵巣癌 | -参加者がカルボプラチンおよび/またはシスプラチンに対するアレルギーまたは重度の不耐性を有するプラチナ感受性卵管癌 | -参加者がカルボプラチンおよび/またはシスプラチンに対するアレルギーまたは重度の不耐性を有するプラチナ感受性の原発性腹膜癌
-
NCT06961786積極的、募集していない