A Difference in Subclavian Vein Catheterization Between Supine and Lateral Tilt Position - Stage I
A Difference in the Cross-section Area of Subclavian Vein Between Supine and Lateral Tilt Position: Its Clinical Impact on Subclavian Venous Catheterization - Stage II
Central venous catheterization is widely used for various purposes during surgery. For central venous catheterization, subclavian vein is selected because of the relatively low risk of infection, long-term patency and low patient discomfort. The cross - sectional area of the subclavian vein is an important factor to increase success rate. Several studies have reported that the Trendelenburg position increases the cross-sectional area of the subclavian vein, and the lateral tilt position can change the cross-sectional area of the subclavian vein. However, the impact of lateral tilt position to the cross-sectional area of the subclavian vein is not clear. The ipsilateral position can increase the cross-sectional area of the subclavian vein, and the contralateral position can decrease the cross-sectional area by gravity.
In the first stage of this study, we compare the cross-sectional area of subclavian vein using ultrasonography in supine, ipsilateral, and contralateral tilt position.
Studieoversigt
Status
Status
Betingelser
Betingelser
Intervention / Behandling
Intervention / Behandling
Undersøgelsestype
Undersøgelsestype
Tilmelding (Forventet)
Tilmelding
Fase
Fase
- Ikke anvendelig
Deltagelseskriterier
Berettigelseskriterier
Berettigelseskriterier
Aldre berettiget til at studere
Tager imod sunde frivillige
Køn, der er berettiget til at studere
Beskrivelse
Inclusion Criteria:
- the patients who receive elective neurosurgical surgery and require central venous catheter
Exclusion Criteria:
- the patients who have puncture site infection
- the patients who have chemoport, pacemaker in right subclavian vein
- the patients who had received right mastectomy or right pneumonectomy
- other contraindications for subclavian venous catheterization (eg. mass, hematoma, vegetation, and anticoagulation)
Studieplan
Hvordan er undersøgelsen tilrettelagt?
Design detaljer
- Primært formål: Diagnostisk
- Tildeling: Randomiseret
- Interventionel model: Crossover opgave
- Maskning: Ingen (Åben etiket)
Antal våben
Våben og indgreb
Deltagergruppe / ArmDeltagergruppe / Arm |
Intervention / BehandlingIntervention / Behandling |
|---|---|
|
Eksperimentel: Ipsilateral tilt
Measuring the cross-sectional area of right subclavian vein in the 20 degree left tilting posture.
|
Operationsbordet vippes 20 grader til højre på siden.
|
|
Ingen indgriben: Supine
Measuring the cross-sectional area of right subclavian vein in supine position.
|
|
|
Aktiv komparator: Contralateral tilt
Measuring the cross-sectional area of right subclavian vein in the 20 degree left tilting posture.
|
The operation table will be tilted 20 degrees left laterally.
|
Hvad måler undersøgelsen?
Primære resultatmål
Primære resultatmål
Resultatmål |
Foranstaltningsbeskrivelse |
Tidsramme |
|---|---|---|
|
The cross-sectional area of right subclavian vein
Tidsramme: 1 minutes after position change
|
The cross-sectional area of right subclavian vein
|
1 minutes after position change
|
Samarbejdspartnere og efterforskere
Sponsor
Sponsor
Publikationer og nyttige links
Generelle publikationer
- Yoon HK, Lee HC, Kang P, Lee JM, Park HP, Cho YJ. Effects of ipsilateral tilt position on the cross-sectional area of the subclavian vein and the clinical performance of subclavian vein catheterization: a prospective randomized trial. BMC Anesthesiol. 2020 Sep 5;20(1):226. doi: 10.1186/s12871-020-01144-1.
- Jung DE, Lee HC, Yoon HK, Park HP. The effects of ipsilateral tilt position on right subclavian venous catheterization: study protocol for a prospective randomized trial. Trials. 2018 May 24;19(1):292. doi: 10.1186/s13063-018-2666-8.
Datoer for undersøgelser
Studer store datoer
Studiestart (Forventet)
Studiestart
Primær færdiggørelse (Forventet)
Primær færdiggørelse
Studieafslutning (Forventet)
Studieafslutning
Datoer for studieregistrering
Først indsendt
Først indsendt
Først indsendt, der opfyldte QC-kriterier
Først indsendt, der opfyldte QC-kriterier
Først opslået (Faktiske)
Først opslået
Opdateringer af undersøgelsesjournaler
Sidste opdatering sendt (Faktiske)
Sidste opdatering sendt
Sidste opdatering indsendt, der opfyldte kvalitetskontrolkriterier
Sidste opdatering indsendt, der opfyldte kvalitetskontrolkriterier
Sidst verificeret
Sidst verificeret
Mere information
Begreber relateret til denne undersøgelse
Andre undersøgelses-id-numre
Andre undersøgelses-id-numre
- 2017-110-871-1
Lægemiddel- og udstyrsoplysninger, undersøgelsesdokumenter
Studerer et amerikansk FDA-reguleret lægemiddelprodukt
Studerer et amerikansk FDA-reguleret enhedsprodukt
Disse oplysninger blev hentet direkte fra webstedet clinicaltrials.gov uden ændringer. Hvis du har nogen anmodninger om at ændre, fjerne eller opdatere dine undersøgelsesoplysninger, bedes du kontakte register@clinicaltrials.gov. Så snart en ændring er implementeret på clinicaltrials.gov, vil denne også blive opdateret automatisk på vores hjemmeside .
Kliniske forsøg med Ipsilateral tilt
-
NCT03303274UkendtKateterisering | Positur
-
NCT05087953Ikke rekrutterer endnuAmyloide neuropatier | Autonomisk nervesystemsygdom
-
NCT06167291Aktiv, ikke rekrutterendeOrofaryngeale neoplasmer | Robotkirurgi og/eller strålebehandling | Lymfoscintigrafi
-
NCT01966198AfsluttetAutonomisk nervesystemmodulation
-
NCT04570722AfsluttetMelanom | Brystkræft | Lymfødem i overarmen | Thoraxkræft
-
NCT06809582RekrutteringSten, nyre | Sten, nyre | Sten; Nyre
-
NCT02812628Ukendt
-
NCT05551377Aktiv, ikke rekrutterendeParkinsons sygdom | Parkinsonisme