Low-Level EMF Stimulation for Paroxysmal Atrial Fibrillation
Effect of Low-Level Electromagnetic Field Stimulation on Patients With Paroxysmal Atrial Fibrillation
調査の概要
状態
状態
条件
条件
介入・治療
介入・治療
詳細な説明
This is a prospective, randomized, sham-controlled trial. Patients will be enrolled upon presentation to our electrophysiology (EP) lab for ablation of paroxysmal AF. After informed consent is obtained, the patient will be randomized to one of two protocols that have been pre-programmed into the magnetic field stimulator. As described below, one of the protocols will be an active stimulation protocol, and one will be sham (i.e. no stimulation delivered). These will be named "Stim 1" and "Stim 2" in the computer. Because the specifics of the protocol are programmed into the stimulator by the device manufacturer, investigators will not know which of these two protocols is active vs. sham. The patient will then be brought to the EP lab for the procedure and will be placed on the lab table with their head positioned in the magnetic coil. Vascular access will then be obtained and diagnostic catheters placed as is standard practice for AF ablation.
Because the study is limited to patients with paroxysmal AF, patients will begin the study in normal sinus rhythm (NSR). Before the experimental protocol is begun, baseline electrophysiologic intervals will be recorded as is standard practice for all patients presenting for EP study. This will include measurement of the atrio-ventricular nodal effective refractory period (AVNERP) using programmed stimulation from the right atrial (RA) appendage, atrio-his (AH) interval, and his-ventricular (HV) interval per standard practice. Burst atrial pacing will then be utilized to induce AF. Measurements of the number of burst pacing attempts required to induce AF, as well as the AF cycle length, and duration of pacing-induced AF will be recorded. Attempts at AF induction will occur for 15 minutes. Prior to induction of AF, 5ml of venous blood will be drawn from the central venous sheaths to measure baseline levels of the inflammatory mediator (TNF)-α. These samples will be stored for analysis.
After baseline measurements are obtained, the coil will be turned on and whichever protocol the patient has been assigned to will be run. The system to be used contains a signal-generator coupled to a Helmholtz coil capable of producing a magnetic field in response to an electric current. The Helmholtz coil itself is has 9 inches of separation in between the two coils that allows for placement of the coil around the participant's head and upper neck. The choice of the head and neck as the site of stimulation is intended to target the vagus nerve as it exits the jugular foramen to course caudally in the carotid sheath. The system is designed to create a homogenous, isotropic magnetic field with a field strength from 1 to 99 pico-Tesla (pT) with a frequency range of 0.01 Hz to 50 Hz.
Active Stimulation will involve application of a pulsed-EMF with the parameters 0.032 micro-gauss (µG) at 0.89 Hz for 60 minutes. In participants randomized to sham stimulation, the coil will be positioned around the neck as previously described, but no current will be applied to the stimulator.
During the 60 minute stimulation time, trans-septal puncture and mapping of the left atrium will be performed as is standard practice for this procedure, but no ablation will be performed. After the 60 minute protocol is complete, venous blood samples will again be drawn (within 5 minutes of protocol completion), stored, and analyzed as previously described. If the patient remains in AF after the end of the 60 minute session, they will be electrically cardioverted to sinus rhythm. The same stimulation protocol as described previously will again be employed, again noting number of attempts required to induce AF, duration of pacing-induced AF, AF cycle length, and measurements of AVNERP, AH, HV intervals and levels of TNF-α.
研究の種類
研究の種類
入学 (実際)
入学
段階
段階
- 適用できない
連絡先と場所
研究場所
-
-
Oklahoma
-
Oklahoma City、Oklahoma、アメリカ、73120
- OU Health Sciences Center
-
-
参加基準
適格基準
適格基準
就学可能な年齢
健康ボランティアの受け入れ
受講資格のある性別
説明
Inclusion Criteria:
- Adult patients aged 21-85 presenting for ablation of paroxysmal atrial fibrillation (episodes of atrial fibrillation lasting < 7 days with or without prior cardioversion)
Exclusion Criteria:
- Left ventricular ejection fraction (LVEF) < 40%
- Stroke or myocardial infarction within the past 6 months
- Greater than moderate valvular stenosis or regurgitation as assessed by pre-procedure transthoracic echocardiogram (TTE)
- Presence of a prosthetic heart valve.
研究計画
研究はどのように設計されていますか?
デザインの詳細
- 主な目的:処理
- 割り当て:ランダム化
- 介入モデル:並列代入
- マスキング:4倍
アーム数
武器と介入
参加者グループ / アーム参加者グループ / アーム |
介入・治療介入・治療 |
|---|---|
|
実験的:Active Stimulation
Participants will receive active EMF stimulation through the study device for 60 minutes during the procedure.
|
Low-level pulsed electromagnetic field stimulator delivered through a Helmholtz coil positioned around the participant's head and neck.
Stimulation parameters are 0.032 µG at 0.89 Hz for 60 minutes.
|
|
偽コンパレータ:Sham Stimulation
The participant will be positioned in the stimulator, but no EMF stimulation will be delivered.
|
The stimulator will be placed around the participant's head and neck, but no EMF will be delivered.
|
この研究は何を測定していますか?
主要な結果の測定
主要な結果の測定
結果測定 |
メジャーの説明 |
時間枠 |
|---|---|---|
|
Change in duration of pacing-induced atrial fibrillation
時間枠:60 minutes
|
Change in the duration of atrial fibrillation that is induced by burst-pacing compared between the two groups before and after the stimulation period.
|
60 minutes
|
二次結果の測定
二次結果の測定
結果測定 |
メジャーの説明 |
時間枠 |
|---|---|---|
|
Number of pacing attempts required to induce AF
時間枠:60 minutes
|
Number of burst-pacing attempts that are required to successfully induced atrial fibrillation, compared between the two groups before and after the stimulation period.
|
60 minutes
|
|
AF Cycle length
時間枠:60 minutes
|
Cycle length of induced atrial fibrillation, compared between the two groups before and after the stimulation period.
|
60 minutes
|
|
TNF-alpha levels
時間枠:60 minutes
|
Levels of the inflammatory mediator TNF-alpha measured in central venous blood, compared between the two groups before and after the stimulation period.
|
60 minutes
|
協力者と研究者
捜査官
捜査官
- 主任研究者:Sunny Po, MD, PhD、University of Oklahoma
出版物と役立つリンク
一般刊行物
- Chen PS, Chen LS, Fishbein MC, Lin SF, Nattel S. Role of the autonomic nervous system in atrial fibrillation: pathophysiology and therapy. Circ Res. 2014 Apr 25;114(9):1500-15. doi: 10.1161/CIRCRESAHA.114.303772.
- Stavrakis S, Humphrey MB, Scherlag BJ, Hu Y, Jackman WM, Nakagawa H, Lockwood D, Lazzara R, Po SS. Low-level transcutaneous electrical vagus nerve stimulation suppresses atrial fibrillation. J Am Coll Cardiol. 2015 Mar 10;65(9):867-75. doi: 10.1016/j.jacc.2014.12.026.
- Wang S, Zhou X, Wang Z, Huang B, Zhou L, Chen M, Yu L, Jiang H. Magnetic fields in noninvasive heart stimulation: A novel approach for anti-atrial fibrillation. Int J Cardiol. 2015;190:54-5. doi: 10.1016/j.ijcard.2015.04.155. Epub 2015 Apr 21. No abstract available.
- Scherlag BJ, Yamanashi WS, Hou Y, Jacobson JI, Jackman WM, Lazzara R. Magnetism and cardiac arrhythmias. Cardiol Rev. 2004 Mar-Apr;12(2):85-96. doi: 10.1097/01.crd.0000094029.10223.2f.
- Yu L, Dyer JW, Scherlag BJ, Stavrakis S, Sha Y, Sheng X, Garabelli P, Jacobson J, Po SS. The use of low-level electromagnetic fields to suppress atrial fibrillation. Heart Rhythm. 2015 Apr;12(4):809-17. doi: 10.1016/j.hrthm.2014.12.022. Epub 2014 Dec 19.
研究記録日
主要日程の研究
研究開始 (実際)
研究開始
一次修了 (実際)
一次修了
研究の完了 (実際)
研究の完了
試験登録日
最初に提出
最初に提出
QC基準を満たした最初の提出物
QC基準を満たした最初の提出物
最初の投稿 (実際)
最初の投稿
学習記録の更新
投稿された最後の更新 (実際)
投稿された最後の更新
QC基準を満たした最後の更新が送信されました
QC基準を満たした最後の更新が送信されました
最終確認日
最終確認日
詳しくは
本研究に関する用語
その他の研究ID番号
その他の研究ID番号
- EMF for Atrial Fibrillation
個々の参加者データ (IPD) の計画
個々の参加者データ (IPD) を共有する予定はありますか?
医薬品およびデバイス情報、研究文書
米国FDA規制医薬品の研究
米国FDA規制機器製品の研究
米国で製造され、米国から輸出された製品。
この情報は、Web サイト clinicaltrials.gov から変更なしで直接取得したものです。研究の詳細を変更、削除、または更新するリクエストがある場合は、register@clinicaltrials.gov。 までご連絡ください。 clinicaltrials.gov に変更が加えられるとすぐに、ウェブサイトでも自動的に更新されます。