成人先天性心臓の解剖学的構造および血行動態の評価におけるガドピクレノールの比較有効性
The goal of this clinical trial is to learn how well and at what doses gadopiclenol, a new intravenous (IV) contrast agent used for MRI, works to produce high-quality MRI images of the heart, in patients with a history of congenital heart disease, when compared to gadobenate dimeglumine, the IV contrast agent that is normally used at our institution for heart (cardiac) MRI. The main questions it aims to answer are:
- Does using gadopiclenol result in similar or superior image quality, similar signal-to-noise ratio (SNR), and similar flow measurements with 4-dimensional (4D) flow cardiac MRI when compared to gadobenate dimeglumine?
- At what dose(s) does gadopiclenol result in similar image quality (using the above metrics) for cardiac MRI when compared to gadobenate dimeglumine?
Researchers will compare cardiac MRI images obtained after administration of gadopiclenol to cardiac MRI images obtained after administration of gadobenate dimeglumine (called the standard of care treatment) to see if the images are of similar or superior quality.
Participants will:
- Be randomized to receive either gadopiclenol at one of three different doses or gadobenate dimeglumine before their congenital heart cardiac MRI
- Undergo their congenital heart cardiac MRI as they would during the course of normal clinical care.
調査の概要
状態
状態
条件
条件
介入・治療
介入・治療
詳細な説明
At the University of California San Diego (UCSD), the investigators have developed a premier advanced clinical cardiovascular imaging program, which is a critical component of our Adult Congenital Heart Association (ACHA)-accredited adult congenital heart program. Central to these programs is 4D Flow MRI, which enables hemodynamic assessment of patients with repaired and unrepaired congenital heart disease. Adults with congenital heart disease require routine MRI for surveillance and management of complications of disease and repairs, and 4D Flow allows us to reliably perform these exams efficiently and accurately. Multiple works by our group, and confirmed by others, have highlighted the value of 4D Flow MRI for evaluating this patient population, and for vascular imaging applications beyond the heart.
Gadopiclenol is a recently FDA-approved intravenous, extracellular gadolinium contrast agent indicated for use in MRI. Though it has been shown to be effective in detection of central nervous system (CNS) lesions and of lesions outside the CNS, its performance in cardiovascular imaging is unknown, particularly in cardiac MRI performed for evaluation of adult congenital heart disease. The investigators therefore seek to evaluate whether use of gadopiclenol results in superior image quality compared to, and therefore may be used in place of, gadobenate dimeglumine, our current standard of care in 4D Flow MRI and MR Angiography (MRA).
In our current clinical practice, like many others, gadobenate dimeglumine at 0.3 mL/kg (0.15 mmol/kg) is our standard of care for vascular enhancement and cardiac MRI, favored due to its long blood pool residence time, which parallels the longer acquisition time for 4D Flow MRI (~10 minutes), and its strong T1 shortening properties. Gadopiclenol, with its stronger T1 shortening properties and similar pharmacokinetics, may achieve similar effects but as a macrocyclic agent is a more stable gadolinium agent, and theoretically may have a better retention profile than older linear agents due to its lower approved dose. The investigators therefore seek to determine whether gadopiclenol may be used in place of gadobenate dimeglumine for contrast-enhanced 4D Flow MRI and MRA. Since the optimal dose of gadopiclenol for this purpose is unknown, the investigators will assess the relative performance of gadopiclenol across a dose range.
Standard dosing for gadopiclenol for CNS and abdominal imaging in adult and pediatric patients is 0.05 mmol/kg actual body weight (equivalent to 0.1 mL/kg). However, its safety has been evaluated at doses ranging from 0.025 mmol/kg to 0.3 mmol/kg. The investigators therefore plan to assess the signal to noise ratio and image quality of patients undergoing cardiac MRI using gadopiclenol at three doses (0.075 mmol/kg, 0.10 mmol/kg, 0.15 mmol/kg) against our standard of care (gadobenate dimeglumine at 0.3 mL/kg (0.15 mmol/kg)). The investigators hypothesize that gadopiclenol at each dose will be non-inferior to gadobenate dimeglumine, achieving similar qualitative image quality, similar SNR, and similar standard deviation amongst flow measurements with 4D Flow MRI. There is a strong possibility that gadopiclenol at an equimolar gadolinium dose to gadobenate dimeglumine will provide superior qualitative image quality and superior SNR in contrast-enhanced MRA and reduce standard deviation amongst flow measurements with 4D Flow MRI.
研究の種類
研究の種類
入学 (実際)
入学
段階
段階
- フェーズ 3
連絡先と場所
研究場所
-
-
California
-
San Diego、California、アメリカ、92037
- University of California San Diego Health
-
-
参加基準
適格基準
適格基準
就学可能な年齢
健康ボランティアの受け入れ
受講資格のある性別
説明
Inclusion Criteria:
- Adult patients (≥ 18 years old)
- History of congenital heart disease and scheduled to undergo standard of care cardiac MRI and chest MRA as part of routine clinical care
- English is patient's primary spoken language
Exclusion Criteria:
- Pediatric patients
- Pregnant patients
- Patients with ongoing acute kidney injury (AKI) or severe, chronic kidney disease (GFR < 30 mL/min/1.73m2)
- History of hypersensitivity reaction to gadolinium based contrast agent
- English is not the patient's primary spoken language
研究計画
研究はどのように設計されていますか?
デザインの詳細
- 主な目的:他の
- 割り当て:ランダム化
- 介入モデル:並列代入
- マスキング:トリプル
アーム数
武器と介入
参加者グループ / アーム参加者グループ / アーム |
介入・治療介入・治療 |
|---|---|
|
アクティブコンパレータ:ガドベン酸ジメグルミン 0.15 mmol/kg (標準治療)
|
Gadobenate dimeglumine is an FDA-approved GBCA that is used in standard clinical practice at UCSD for contrast-enhanced MRI/MRA studies, including cardiac MRI/MRA. This contrast agent is the standard of care to which gadopiclenol will be compared.
他の名前:
|
|
実験的:ガドピクレノール 0.075 mmol/kg
|
Gadopiclenol is an FDA-approved gadolinium-based contrast agent (GBCA) for neurological and abdominal contrast-enhanced MRI. Participants will receive this contrast agent at one of three different doses prior to undergoing a congenital heart cardiac MRI/MRA. This contrast agent will be compared to gadobenate dimeglumine, the standard-of-care.
他の名前:
|
|
実験的:ガドピクレノール 0.10 mmol/kg
|
Gadopiclenol is an FDA-approved gadolinium-based contrast agent (GBCA) for neurological and abdominal contrast-enhanced MRI. Participants will receive this contrast agent at one of three different doses prior to undergoing a congenital heart cardiac MRI/MRA. This contrast agent will be compared to gadobenate dimeglumine, the standard-of-care.
他の名前:
|
|
実験的:ガドピクレノール 0.15 mmol/kg
|
Gadopiclenol is an FDA-approved gadolinium-based contrast agent (GBCA) for neurological and abdominal contrast-enhanced MRI. Participants will receive this contrast agent at one of three different doses prior to undergoing a congenital heart cardiac MRI/MRA. This contrast agent will be compared to gadobenate dimeglumine, the standard-of-care.
他の名前:
|
この研究は何を測定していますか?
主要な結果の測定
主要な結果の測定
結果測定 |
メジャーの説明 |
時間枠 |
|---|---|---|
|
Image Quality
時間枠:Image Quality will be assessed on a rolling basis during the study by all radiologists and will be completed within one month of the conclusion of enrollment.
|
Images will be qualitatively scored by three attending radiologists for quality of contrast enhancement on a 5-point likert Scale |
Image Quality will be assessed on a rolling basis during the study by all radiologists and will be completed within one month of the conclusion of enrollment.
|
|
Signal-to-Noise Ratio (SNR)
時間枠:SNR will be assessed on a rolling basis during the study by the study team and will be completed within one month of the conclusion of enrollment.
|
Signal-to-noise will be measured from the blood pool in the aorta and main pulmonary artery and compared against myocardial signal for contrast-to-background calculations in contrast-enhanced MRA and 4D Flow signal images. This ca be readily performed by placing a region of interest (ROI) within the vessel of interest and calculating the standard deviation of signal intensities relative to mean signal intensity. |
SNR will be assessed on a rolling basis during the study by the study team and will be completed within one month of the conclusion of enrollment.
|
|
Standard Deviation of Volumetric Flow Measurements
時間枠:Standard deviation of flow measurements will be assessed on a rolling basis during the study by all attending radiologists and will be completed within one month after the conclusion of enrollment.
|
We will measure standard deviation of volumetric flow measurements from the aorta and main pulmonary artery from ROIs that are typically used in our clinical routine to measure systemic and pulmonary blood flow. The standard error in these measurements will be compared between each of the four randomized conditions. |
Standard deviation of flow measurements will be assessed on a rolling basis during the study by all attending radiologists and will be completed within one month after the conclusion of enrollment.
|
協力者と研究者
協力者
協力者
捜査官
捜査官
- 主任研究者:Albert Hsiao, MD/PhD、Department of Radiology, UC San Diego
出版物と役立つリンク
一般刊行物
- Hsiao A, Alley MT, Massaband P, Herfkens RJ, Chan FP, Vasanawala SS. Improved cardiovascular flow quantification with time-resolved volumetric phase-contrast MRI. Pediatr Radiol. 2011 Jun;41(6):711-20. doi: 10.1007/s00247-010-1932-z. Epub 2011 Jan 11.
- Jacobs K, Hahn L, Horowitz M, Kligerman S, Vasanawala S, Hsiao A. Hemodynamic Assessment of Structural Heart Disease Using 4D Flow MRI: How We Do It. AJR Am J Roentgenol. 2021 Dec;217(6):1322-1332. doi: 10.2214/AJR.21.25978. Epub 2021 Jun 2.
- Kebebew E, Tresler PA, Siperstein AE, Duh QY, Clark OH. Normal thyroid pathology in patients undergoing thyroidectomy for finding a RETgene germline mutation: a report of three cases and review of the literature. Thyroid. 1999 Feb;9(2):127-31. doi: 10.1089/thy.1999.9.127.
研究記録日
主要日程の研究
研究開始 (実際)
研究開始
一次修了 (実際)
一次修了
研究の完了 (実際)
研究の完了
試験登録日
最初に提出
最初に提出
QC基準を満たした最初の提出物
QC基準を満たした最初の提出物
最初の投稿 (実際)
最初の投稿
学習記録の更新
投稿された最後の更新 (実際)
投稿された最後の更新
QC基準を満たした最後の更新が送信されました
QC基準を満たした最後の更新が送信されました
最終確認日
最終確認日
詳しくは
本研究に関する用語
その他の研究ID番号
その他の研究ID番号
- IRB #809813
個々の参加者データ (IPD) の計画
個々の参加者データ (IPD) を共有する予定はありますか?
医薬品およびデバイス情報、研究文書
米国FDA規制医薬品の研究
米国FDA規制機器製品の研究
米国で製造され、米国から輸出された製品。
この情報は、Web サイト clinicaltrials.gov から変更なしで直接取得したものです。研究の詳細を変更、削除、または更新するリクエストがある場合は、register@clinicaltrials.gov。 までご連絡ください。 clinicaltrials.gov に変更が加えられるとすぐに、ウェブサイトでも自動的に更新されます。