TES HT100 軽度頭部外傷または神経症状を有する患者の脳損傷スクリーニングにおける臨床的検証 (TESCO)
TES HT100 臨床アウトカム - 軽度頭部外傷または神経症状が疑われる患者における脳損傷スクリーニングのためのTES HT100テムノグラフの臨床検証(TESCO)
The goal of this clinical study is to evaluate how accurately and safely the TES HT100 device can identify intracranial abnormalities in adult emergency department patients with mild head trauma or neurological symptoms that are not related to trauma and are not immediately life-threatening. The main questions it aims to answer are:
- How well does TES HT100 identify patients with intracranial abnormalities compared with head CT, the reference standard?
- Is TES HT100 safe to use in this patient population?
- Could TES HT100 help improve patient triage and use of hospital resources in the emergency setting?
Researchers will compare the result of TES HT100 with the head CT report.
Participants will:
- Be enrolled if they are adults presenting to the emergency department with mild head trauma or selected neurological symptoms
- Undergo standard clinical assessment and head CT according to usual care
- Have an additional TES HT100 examination lasting about 5 minutes, performed by trained personnel
- Be assessed for device performance and any adverse events related to use of the device
調査の概要
状態
状態
条件
条件
介入・治療
介入・治療
詳細な説明
This is a prospective, multicenter, open-label clinical investigation evaluating the TES HT100 as a non-invasive adjunctive screening device for detection of intracranial abnormalities in adult Emergency Department patients. The study is being conducted in three centers in Italy and Poland.
TES HT100 is intended for non-invasive detection of endocerebral lesions. The device used in this investigation is TES HT model 100, equipped with software version 1.3 or later and firmware version 1.4 or later, in the same configuration planned for commercialization. The system uses non-ionizing, ultra-low-power electromagnetic waves in the 500-6500 MHz frequency range and provides a binary result indicating the presence or absence of intracranial abnormality. The examination is brief, with an overall duration of about 5 minutes.
The study is designed to evaluate the diagnostic performance and safety of TES HT100 when used in addition to standard emergency care. Participants undergo routine clinical assessment and brain CT according to usual clinical practice, and the TES HT100 examination is performed as an add-on procedure. The reference standard for performance evaluation is the brain CT report. TES HT100 is not intended to replace standard clinical assessment or CT imaging.
To reduce interpretation bias, the TES HT100 examination is performed by trained personnel who do not have access to the CT report at the time of testing, and the radiologist interpreting the CT scan is blinded to the TES HT100 result. TES HT100 examinations are performed within 24 hours before or after CT, according to site workflow.
The investigation plans to enroll approximately 850 participants overall across two clinical cohorts. The study duration is planned to be 30 months. Three TES HT100 devices, one per participating center, will be used under the same qualification and maintenance procedures.
In addition to diagnostic validation against CT, the study includes safety monitoring during device use and an exploratory assessment of the potential clinical utility of TES HT100 in emergency department triage and resource management. The overall objective is to generate clinical evidence on the performance and safety of TES HT100 as a rapid, non-invasive screening support tool in the emergency setting.
研究の種類
研究の種類
入学 (推定)
入学
段階
段階
- 適用できない
連絡先と場所
研究連絡先
研究連絡先
- 名前:Fabrizio Alfieri
- 電話番号:+39-081-19189806
- メール:fabrizio.alfieri@temnography.com
研究場所
-
-
CE
-
Castel Volturno、CE、イタリア、81030
- 募集
- Pineta Grande Hospital
-
コンタクト:
- Dorotea Cerbarano
- 電話番号:+39-0823-854111
- メール:dorotea.cerbarano@pinetagrande.it
-
副調査官:
- Angelo Localzo, Registered Nurse
-
副調査官:
- Esaù Russo, Registered Nurse
-
主任研究者:
- Adriana Modestina Conte, MD
-
副調査官:
- Antonia Sorbo, MD - Radiologist
-
-
-
-
-
Gdansk、ポーランド、80-952
- まだ募集していません
- Emergency Department, University Clinical Centre, Medical University of Gdańsk
-
コンタクト:
- Paweł Nowicki
- 電話番号:+48 730 505 991
- メール:nowicki.p@wp.pl
-
主任研究者:
- Mariusz Siemiński, prof. dr hab. n. med.
-
Katowice、ポーランド、40-635
- 募集
- Emergency Department, Leszek Giec Upper Silesian Medical Centre of the Medical University of Silesia in Katowice
-
コンタクト:
- Anna Lis, dr med.
- 電話番号:+48 600 198 608
- メール:lis.anna.agn@icloud.com
-
主任研究者:
- Mateusz Majewski, dr n. med.
-
-
参加基準
適格基準
適格基準
就学可能な年齢
健康ボランティアの受け入れ
受講資格のある性別
説明
Inclusion Criteria:
- Age greater than 18 years
- Provision of informed consent
- Presentation to the Emergency Department with mild head injury, or
- Presentation to the Emergency Department for non-traumatic neurological symptoms and not in a critical condition, including:
- syncope
- spatial disorientation and/or loss of balance
- speech disturbance and/or facial hemi-paresis
- visual alterations
- memory loss and/or confusional state
Exclusion Criteria:
- Age less than 18 years
- Pregnant women
- Metal plates or metal prostheses installed in the skull cap
- Severe head trauma and/or extensive lacerated-contused areas
- Critical condition
- Visible skull fracture
- Failure or inability to provide signed informed consent
研究計画
研究はどのように設計されていますか?
デザインの詳細
- 主な目的:診断
- 割り当て:なし
- 介入モデル:単一グループの割り当て
- マスキング:なし(オープンラベル)
アーム数
武器と介入
参加者グループ / アーム参加者グループ / アーム |
介入・治療介入・治療 |
|---|---|
|
実験的:TES HT100 Examination
All enrolled participants receive standard emergency department evaluation, including head CT according to usual clinical practice, and undergo an additional TES HT100 examination as an add-on procedure. TES HT100 is evaluated against the head CT report used as the reference standard. The study includes adults with mild head injury and adults with neurological symptoms not related to head trauma and not in a critical or life-threatening condition. |
A non-invasive, add-on diagnostic examination performed with the TES HT100 device to assess the presence or absence of intracranial abnormality in adult emergency department patients. The device uses ultra-low-power, non-ionizing electromagnetic waves in the 500-6500 MHz range and provides a binary on/off result. The examination lasts about 5 minutes, does not require direct contact with the patient's head, and is performed by trained personnel in addition to standard clinical evaluation and head CT. |
この研究は何を測定していますか?
主要な結果の測定
主要な結果の測定
結果測定 |
メジャーの説明 |
時間枠 |
|---|---|---|
|
Diagnostic accuracy of TES HT100 for detection of intracranial abnormalities
時間枠:At the index emergency department visit, with TES HT100 performed within 24 hours before or after head CT
|
Diagnostic performance of TES HT100 compared with the head CT report as the reference standard, assessed by ROC-AUC and by sensitivity and specificity for identification of intracranial abnormalities. |
At the index emergency department visit, with TES HT100 performed within 24 hours before or after head CT
|
|
Rate of device-related adverse events
時間枠:From TES HT100 examination through study participation completion, an average of 1 year
|
Incidence and type of adverse events related to the use of TES HT100 during the study. |
From TES HT100 examination through study participation completion, an average of 1 year
|
二次結果の測定
二次結果の測定
結果測定 |
メジャーの説明 |
時間枠 |
|---|---|---|
|
Operator time associated with TES HT100-supported screening
時間枠:Day 1
|
Descriptive evaluation of operator time associated with use of TES HT100 during emergency department screening, based on the number of TES HT100 examinations performed per participant and the approximate duration of each examination (about 5 minutes), as described in the protocol. |
Day 1
|
|
Procedures associated with TES HT100-supported screening
時間枠:Day 1
|
Descriptive evaluation of workflow-related procedures associated with use of TES HT100 during emergency department screening, as part of the exploratory assessment of potential clinical benefit described in the protocol. This may include patient handling or organizational procedures required during the diagnostic pathway, such as patient transfer to a different bed or room or need for additional staff support. |
Day 1
|
|
Costs associated with TES HT100-supported screening
時間枠:Day 1
|
Descriptive evaluation of resource use and related cost considerations associated with use of TES HT100 during emergency department screening, as part of the exploratory assessment of potential clinical benefit described in the protocol. |
Day 1
|
|
Diagnostic performance of TES HT100 in predefined patient subgroups
時間枠:At the index emergency department visit, with TES HT100 performed within 24 hours before or after head CT
|
Analysis of TES HT100 diagnostic performance, based on sensitivity and specificity versus head CT, in predefined subgroups, including younger patients, older patients, patients with or without prior injury or brain surgery, and patients with or without neurodegenerative disease. |
At the index emergency department visit, with TES HT100 performed within 24 hours before or after head CT
|
協力者と研究者
捜査官
捜査官
- スタディディレクター:Fabrizio Alfieri、B&B srl
出版物と役立つリンク
一般刊行物
- Brazinova A, Rehorcikova V, Taylor MS, Buckova V, Majdan M, Psota M, Peeters W, Feigin V, Theadom A, Holkovic L, Synnot A. Epidemiology of Traumatic Brain Injury in Europe: A Living Systematic Review. J Neurotrauma. 2021 May 15;38(10):1411-1440. doi: 10.1089/neu.2015.4126. Epub 2018 Dec 19.
- Cuccaro A, et al. Microwave Radar Imaging as a Tool for Medical Diagnostics. Eng Proc. 2023.
- Solimene R, et al. An Incoherent Radar Imaging System for Medical Applications. IEEE CAMA 2021.
- Vaia S, Iavarone A, et al. HT temnography in the early diagnosis of brain lesions due to ischemic or hemorrhagic stroke. Int J Adv Res. 2023.
- Montemerani S, Fabrizi C, Sacchi C, Belperio A, Moriani L, Pacchi S, Garofalo C, Sbrana G, Venezia D, Zanobetti M, Nocentini S. Reliability Evaluation of Temnography for Early Detection of Intracranial Lesions in Mild Traumatic Brain Injury Patient: A Preliminary Report of a New Portable, Non-Invasive Device. Open Access Emerg Med. 2024 Dec 6;16:313-321. doi: 10.2147/OAEM.S475328. eCollection 2024.
- Islam MS, Islam MT, Almutairi AF. Experimental tissue mimicking human head phantom for estimation of stroke using IC-CF-DMAS algorithm in microwave based imaging system. Sci Rep. 2021 Nov 10;11(1):22015. doi: 10.1038/s41598-021-01486-x.
- Gabriel S, Lau RW, Gabriel C. The dielectric properties of biological tissues: II. Measurements in the frequency range 10 Hz to 20 GHz. Phys Med Biol. 1996 Nov;41(11):2251-69. doi: 10.1088/0031-9155/41/11/002.
- Gabriel C, Gabriel S, Corthout E. The dielectric properties of biological tissues: I. Literature survey. Phys Med Biol. 1996 Nov;41(11):2231-49. doi: 10.1088/0031-9155/41/11/001.
- Lefevre-Dognin C, Cogne M, Perdrieau V, Granger A, Heslot C, Azouvi P. Definition and epidemiology of mild traumatic brain injury. Neurochirurgie. 2021 May;67(3):218-221. doi: 10.1016/j.neuchi.2020.02.002. Epub 2020 May 6.
- Mckee AC, Daneshvar DH. The neuropathology of traumatic brain injury. Handb Clin Neurol. 2015;127:45-66. doi: 10.1016/B978-0-444-52892-6.00004-0.
- Conte AM, Alfieri F, Localzo A, Russo E, Cucinotto I, Trovato A, Gualtieri R, Laccetti E, Sorbo A. Prospective blinded interim evaluation of a portable radiofrequency device TES HT to support triage in emergency department patients with mild head trauma or acute neurological symptoms. BMC Emerg Med. 2026 Jul 7. doi: 10.1186/s12873-026-01676-8. Online ahead of print.
研究記録日
主要日程の研究
研究開始 (実際)
研究開始
一次修了 (推定)
一次修了
研究の完了 (推定)
研究の完了
試験登録日
最初に提出
最初に提出
QC基準を満たした最初の提出物
QC基準を満たした最初の提出物
最初の投稿 (実際)
最初の投稿
学習記録の更新
投稿された最後の更新 (実際)
投稿された最後の更新
QC基準を満たした最後の更新が送信されました
QC基準を満たした最後の更新が送信されました
最終確認日
最終確認日
詳しくは
本研究に関する用語
追加の関連 MeSH 用語
その他の研究ID番号
その他の研究ID番号
- CLV-01-TES HT
個々の参加者データ (IPD) の計画
個々の参加者データ (IPD) を共有する予定はありますか?
IPD プランの説明
De-identified participant-level data may be shared upon reasonable request, subject to ethics and institutional approval where applicable and execution of a data sharing agreement. Public sharing is not planned due to confidentiality and consent restrictions.
医薬品およびデバイス情報、研究文書
米国FDA規制医薬品の研究
米国FDA規制機器製品の研究
この情報は、Web サイト clinicaltrials.gov から変更なしで直接取得したものです。研究の詳細を変更、削除、または更新するリクエストがある場合は、register@clinicaltrials.gov。 までご連絡ください。 clinicaltrials.gov に変更が加えられるとすぐに、ウェブサイトでも自動的に更新されます。