このページは自動翻訳されたものであり、翻訳の正確性は保証されていません。を参照してください。 英語版 ソーステキスト用。

腰椎手術における腹臥位での呼吸力学に対する5 cmH₂Oと8 cmH₂O PEEPの比較 (PROPEEP)

2026年11月13日 更新者:Veli Fahri Pehlivan、Harran University

TIVA下の腹臥位で行われる腰椎手術におけるPCV-VGモードに伴う異なるPEEPレベルが呼吸力学とガス交換に及ぼす影響

This randomized controlled clinical trial aims to compare the effects of two different positive end-expiratory pressure (PEEP) levels (5 cmH₂O and 8 cmH₂O) on respiratory mechanics in patients undergoing lumbar spine surgery in the prone position under total intravenous anesthesia (TIVA). Prone positioning may adversely affect lung compliance and gas exchange, making optimal ventilatory strategies essential. Driving pressure and mechanical power are considered key determinants of ventilator-induced lung stress. This study will evaluate the impact of different PEEP levels on respiratory parameters and intraoperative physiological changes.

調査の概要

状態

まだ募集していません

条件

介入・治療

詳細な説明

Prone positioning during lumbar spine surgery is associated with increased intrathoracic pressure, reduced lung compliance, and impaired ventilation-perfusion matching, which may negatively affect respiratory mechanics and gas exchange. Mechanical ventilation strategies, particularly the application of positive end-expiratory pressure (PEEP), play a critical role in preventing atelectasis and optimizing oxygenation.

Pressure-controlled ventilation with volume guarantee (PCV-VG) is a modern ventilation mode that ensures target tidal volume delivery while minimizing airway pressures, thereby reducing the risk of ventilator-induced lung injury. In recent years, driving pressure (ΔP) and mechanical power have emerged as important parameters reflecting lung stress and injury during mechanical ventilation.

This prospective randomized controlled trial aims to evaluate the effects of two different PEEP levels (5 cmH₂O and 8 cmH₂O) on respiratory mechanics and gas exchange in patients undergoing lumbar spine surgery in the prone position under total intravenous anesthesia (TIVA). Patients will be randomly assigned into two groups receiving either 5 cmH₂O or 8 cmH₂O PEEP. Ventilation will be standardized using PCV-VG mode with a tidal volume of 6-8 mL/kg predicted body weight and respiratory rate adjusted to maintain normocapnia.

Hemodynamic parameters and respiratory variables, including peak airway pressure, plateau pressure, dynamic compliance, airway resistance, tidal volume, and end-tidal CO₂, will be recorded at predefined time points. Arterial blood gas analyses will be performed at selected intervals to assess gas exchange.

The primary outcome of the study is driving pressure (ΔP), while secondary outcomes include mechanical power, oxygenation parameters, PaCO₂-EtCO₂ gradient, and physiologic dead space fraction (VD/VT).

The findings of this study are expected to provide clinical evidence regarding the optimal PEEP level in prone lumbar surgery and contribute to improving intraoperative lung-protective ventilation strategies.

研究の種類

介入

入学 (推定)

60

段階

  • 適用できない

連絡先と場所

このセクションには、調査を実施する担当者の連絡先の詳細と、この調査が実施されている場所に関する情報が記載されています。

研究連絡先

研究連絡先のバックアップ

参加基準

研究者は、適格基準と呼ばれる特定の説明に適合する人を探します。これらの基準のいくつかの例は、人の一般的な健康状態または以前の治療です。

適格基準

就学可能な年齢

18年~65年 (大人、高齢者)

健康ボランティアの受け入れ

いいえ

受講資格のある性別

全て

説明

Inclusion Criteria:

  • Patients aged between 18 and 65 years
  • American Society of Anesthesiologists (ASA) physical status I-II
  • Scheduled for elective lumbar spine surgery in the prone position
  • Planned general anesthesia with total intravenous anesthesia (TIVA)
  • Ability to provide informed consent

Exclusion Criteria:

  • Body mass index (BMI) ≥ 30 kg/m²
  • History of significant pulmonary disease (e.g., COPD, asthma)
  • Severe cardiovascular disease
  • Pregnancy
  • Known difficult airway
  • Requirement for intraoperative vasopressor infusion due to hemodynamic instability
  • Conversion to different surgical position or change in surgical plan
  • Incomplete data or protocol deviation

研究計画

このセクションでは、研究がどのように設計され、研究が何を測定しているかなど、研究計画の詳細を提供します。

研究はどのように設計されていますか?

デザインの詳細

  • 主な目的:処理
  • 割り当て:ランダム化
  • 介入モデル:並列代入
  • マスキング:なし(オープンラベル)

武器と介入

参加者グループ / アーム
介入・治療
実験的:PEEP-5 Group

Participants in this group will receive mechanical ventilation with a positive end-expiratory pressure (PEEP) level of 5 cmH₂O during lumbar spine surgery in the prone position under total intravenous anesthesia (TIVA). Ventilation will be performed using PCV-VG mode with a target tidal volume of 6-8 mL/kg predicted body weight and respiratory rate adjusted to maintain normocapnia.

Mechanical ventilation will be applied using pressure-controlled ventilation with volume guarantee (PCV-VG) mode during prone lumbar surgery under total intravenous anesthesia (TIVA). Two different positive end-expiratory pressure (PEEP) levels (5 cmH₂O and 8 cmH₂O) will be used according to group allocation. Tidal volume will be set at 6-8 mL/kg predicted body weight, and respiratory rate will be adjusted to maintain normocapnia (EtCO₂ 35-40 mmHg).

他の名前:
  • 肺保護換気
  • PCV-VG換気
実験的:PEEP-8 Group

Participants in this group will receive mechanical ventilation with a positive end-expiratory pressure (PEEP) level of 8 cmH₂O during lumbar spine surgery in the prone position under total intravenous anesthesia (TIVA). Ventilation will be performed using PCV-VG mode with a target tidal volume of 6-8 mL/kg predicted body weight and respiratory rate adjusted to maintain normocapnia.

Mechanical ventilation will be applied using pressure-controlled ventilation with volume guarantee (PCV-VG) mode during prone lumbar surgery under total intravenous anesthesia (TIVA). Two different positive end-expiratory pressure (PEEP) levels (5 cmH₂O and 8 cmH₂O) will be used according to group allocation. Tidal volume will be set at 6-8 mL/kg predicted body weight, and respiratory rate will be adjusted to maintain normocapnia (EtCO₂ 35-40 mmHg).

他の名前:
  • 肺保護換気
  • PCV-VG換気

この研究は何を測定していますか?

主要な結果の測定

結果測定
メジャーの説明
時間枠
Driving Pressure (ΔP)
時間枠:Intraoperative period (at predefined time points: T0, T2, T5)

Driving pressure (ΔP), calculated as the difference between plateau pressure (Pplat) and positive end-expiratory pressure (PEEP), will be used as the primary outcome to assess lung stress during mechanical ventilation.

Intraoperative period (at predefined time points: T0, T2, T5)

二次結果の測定

結果測定
メジャーの説明
時間枠
Mechanical Power
時間枠:Intraoperative period (T0, T2, T5)

Mechanical power will be calculated to quantify the energy delivered to the respiratory system during mechanical ventilation.

Intraoperative period (T0, T2, T5)
Oxygenation (PaO₂/FiO₂ Ratio)
時間枠:Intraoperative period (T0, T2, T5)

Oxygenation status will be assessed using the arterial oxygen partial pressure to inspired oxygen fraction (PaO₂/FiO₂) ratio.

Intraoperative period (T0, T2, T5)
PaCO₂-EtCO₂ Gradient
時間枠:Intraoperative period (T0, T2, T5)

The difference between arterial carbon dioxide pressure (PaCO₂) and end-tidal CO₂ (EtCO₂) will be used to evaluate ventilation-perfusion mismatch.

Intraoperative period (T0, T2, T5)
Physiological Dead Space Fraction (VD/VT)
時間枠:Intraoperative period (T0, T2, T5)

Physiological dead space fraction will be calculated using the Bohr equation to assess ventilation efficiency.

Intraoperative period (T0, T2, T5)
Dynamic Lung Compliance (Cdyn)
時間枠:Intraoperative period (all time points)

Dynamic compliance will be recorded to evaluate changes in lung mechanics during ventilation.

Intraoperative period (all time points)
Peak Airway Pressure (Ppeak)
時間枠:Intraoperative period (all time points)

Peak airway pressure will be recorded to assess airway pressure changes during mechanical ventilation.

Intraoperative period (all time points)

協力者と研究者

ここでは、この調査に関係する人々や組織を見つけることができます。

スポンサー

捜査官

  • 主任研究者:Basak Pehlivan, Asoc Prof、Harran University Faculty of Medicine, Department of Anesthesiology

研究記録日

これらの日付は、ClinicalTrials.gov への研究記録と要約結果の提出の進捗状況を追跡します。研究記録と報告された結果は、国立医学図書館 (NLM) によって審査され、公開 Web サイトに掲載される前に、特定の品質管理基準を満たしていることが確認されます。

主要日程の研究

研究開始 (推定)

2026年11月15日

一次修了 (推定)

2027年1月31日

研究の完了 (推定)

2027年3月3日

試験登録日

最初に提出

2026年4月16日

QC基準を満たした最初の提出物

2026年4月16日

最初の投稿 (実際)

2026年4月22日

学習記録の更新

投稿された最後の更新 (実際)

2026年11月16日

QC基準を満たした最後の更新が送信されました

2026年11月13日

最終確認日

2026年11月1日

詳しくは

本研究に関する用語

その他の研究ID番号

  • REŞIT-PEEP-2026

個々の参加者データ (IPD) の計画

個々の参加者データ (IPD) を共有する予定はありますか?

いいえ

医薬品およびデバイス情報、研究文書

米国FDA規制医薬品の研究

いいえ

米国FDA規制機器製品の研究

いいえ

この情報は、Web サイト clinicaltrials.gov から変更なしで直接取得したものです。研究の詳細を変更、削除、または更新するリクエストがある場合は、register@clinicaltrials.gov。 までご連絡ください。 clinicaltrials.gov に変更が加えられるとすぐに、ウェブサイトでも自動的に更新されます。