このページは自動翻訳されたものであり、翻訳の正確性は保証されていません。を参照してください。 英語版 ソーステキスト用。

Assessing Tissue Response to High-Velocity Thrust Manipulations on Capsule Length and Stiffness at the C5-C6 Facet Joint Capsule

2026年8月24日 更新者:Florida Gulf Coast University

Assessing Tissue Response to High-Velocity Thrust Manipulations: Measuring Lasting Changes in C5-C6 Facet Joint Capsule Length With Musculoskeletal Ultrasound and Stiffness With Elastography

This study is a quasi-experimental study collected quantitative data , with a pre-test-post-test design. Pre-intervention, baseline measurements of C5-C6 right facet joint length and width with the head of the treatment plinth downward at 45 and 90 degrees, (relative to the rest of the table) and stiffness at 90 degrees, were taken prior to applying the long-axis thrust manipulation. Post-intervention measures were taken immediately after a long axis thrust manipulation of C5-C6 and again at 24-hours after the manipulation. The baseline pre-intervention measures were then compared to the post-intervention measurements. The investigator performing the manipulation was blinded to the quantitative measurements of the ultrasound images. The ultrasound operator was blinded to the outcome of the manipulation.

調査の概要

状態

完了

条件

介入・治療

詳細な説明

The study takes place in Marieb Hall rooms 101 and 103 of Florida Gulf Coast University. After meeting the inclusion and exclusion criteria subjects sign the informed consent form described thoroughly on the following page. The participants undergo three recording sessions on two consecutive days. The first recording session consist of obtaining participant consent and general information, such as height and weight. The participants then has their baseline measures cervical flexion ROM, capsular length and width at both 45 and 90 degrees, and stiffness at 90 degrees, taken. The second and third session consist only of repeating these baseline measures post-manipulation and 24-hours post-manipulation respectively. Each participant will be provided a profile on the ultrasound unit, corresponding to their subject number, with each point in time having an individual exam within the profile. At these sessions, recordings are done in the prone position to measure length of the C5-C6 joint capsule and joint capsule tissue extensibility. Locating the articular pillar was a three-fold process. At the intervention table, the C7 spinous process is identified in upright sitting with palpation, due to its relevance in clinical examination and evaluation, serving as the first landmark. From this position, one of the measuring practitioners moves their finger cranially to the C6 spinous process. The participant's head is moved passively into extension, causing the spinous process to move away from the practitioner's finger, providing further confidence in location accurary. This landmark isthen marked for repeatability. The participant then has their cervical flexion range of motion measured with a fluid-filled inclinometer. A fluid-filled inclinometer utilizes gravity to quantify gross motion. This method is easily repeated and validated for clinical measurements. Each participant is given the instructions, "sit up straight and tuck your chin to your chest." At the ultrasound table, a goniometer is secured with the stationary arm in line with the table, the axis through the pivot point for the head of the table, and the moving line in line with the head of the table.

The participant is then instructed to lie prone on the table, with the head of the table positioned at 45 degrees. Anytime the head position of the table is altered, two researchers confirmed the angle of the goniometer. The 45 degree angle was selected to neutralize the natural lordosis of the lower cervical spine. The table insert is removed for the participant's face to lie within the opening. A piece of tape is placed at the base of the table opening . The participants are given the instructions, "tuck your chin and put the front of your chin on the piece of tape." From this point, the ultrasound probe is placed in a right paramedian sagittal/long-axis view. The probe was angled 15 degrees from lateral-to-medial in the posterior-to-anterior direction.

Beginning at the occipital bone, the probe is moved inferiorly. The articular pillar is known to have a jagged, sawtooth like appearance when observed from this angle. The trough at the bottom of the sawtooth indicates the inferior articular process of the cranial vertebra, while the following peak will be depicting the superior articular process of the following caudal vertebra.

This allowed the practitioners to count the peaks observed and identify the spinal levels visualized on the screen. The mark placed on the C6 spinous process is compared to probe location once the C6 level has been visualized on the screen. After the level is confirmed to be correct, the probe remained stationary on the participant. Once the correct level is visualized, the first screen capture video was taken and saved to the participant exam. The head of the table is then angled fully down towards the floor, measured at 90 degrees with the secured goniometer. By having the head of the table as far down as it allows, the process for achieving full cervical flexion remained standardized. This is also confirmed via palpation of the interspinous space of T1 and by both practitioners audibly confirming the observation of the thoracic spine flexion, indicating full cervical flexion is achieved. While the capsule could theoretically be put under more tension by utilizing multiplanar movements, utilizing only flexion offers a standardized, repeatable method that is less susceptible to confounding variables. As the probe remains stationary with the C5-C6 joint in view, the second screen capture video is taken. While remaining in the fully flexed position, the ultrasound operator start the elastography on the ultrasound unit. Once displayed on screen, a third screen capture video is taken.

The participant then returns to the initial table to receive the intervention. The practitioner performing the HVLA long axis C6-C6 manipulation on the right stands at the head of the plinth, on the right side of the patient positioned in supine. The practitioner's right hand is placed under C6, while the left hand is placed under the chin as the arm cradles the head. Using the left hand and arm, the practitioner passively rotated the head away and side-bent the head toward the targeted side. Once end-range motion is achieved, the practitioner provides a high-velocity low-amplitude long-axis thrust in a superior direction, parallel to the angle of the targeted segment.

Following the manipulation, the participant has their cervical range of motion re-measured, and the ultrasound imaging process is repeated in a new exam. Once the immediate post-intervention measures are taken, the subjects are instructed to come back for a third imaging session at the exact same time the following day. At the 24-hour follow-up, the participants cervical flexion range of motion is repeated, as well as the three ultrasound procedures.

研究の種類

介入

入学 (実際)

42

段階

  • 適用できない

連絡先と場所

このセクションには、調査を実施する担当者の連絡先の詳細と、この調査が実施されている場所に関する情報が記載されています。

研究連絡先

研究場所

    • Florida
      • Fort Myers、Florida、アメリカ、33965
        • Florida Gulf Coast University Marieb Hall 101

参加基準

研究者は、適格基準と呼ばれる特定の説明に適合する人を探します。これらの基準のいくつかの例は、人の一般的な健康状態または以前の治療です。

適格基準

就学可能な年齢

  • 大人

健康ボランティアの受け入れ

はい

説明

Inclusion Criteria:

  • Healthy individuals between 18-35 without neck pain
  • Able to to read and understand English

Exclusion Criteria:

  • autoimmune disease
  • down syndrome
  • fusion, fracture
  • spinal cord compression
  • vascular pathology
  • cancer,
  • any other conditions that induce severe instability
  • inflammation
  • weakened bone.

研究計画

このセクションでは、研究がどのように設計され、研究が何を測定しているかなど、研究計画の詳細を提供します。

研究はどのように設計されていますか?

デザインの詳細

  • 主な目的:他の
  • 割り当て:なし
  • 介入モデル:単一グループの割り当て
  • マスキング:なし(オープンラベル)

武器と介入

参加者グループ / アーム
介入・治療
実験的:Sample
C5-C6 long axis joint manipulation
Long axis trust manipulation C5-C6

この研究は何を測定していますか?

主要な結果の測定

結果測定
メジャーの説明
時間枠
facet capsule length and width
時間枠:before intervention, immediately after, and at 24 hour follow up
MSK US measure facet length and with in mm
before intervention, immediately after, and at 24 hour follow up

二次結果の測定

結果測定
メジャーの説明
時間枠
Cervical motion
時間枠:before intervention, immediately after, and at 24 hour follow up
Max neck flexion motion in sitting measured in degrees
before intervention, immediately after, and at 24 hour follow up
elastography
時間枠:Before intervention, immediately after, and 24 hours after
tissue pliability assessment with MSK US
Before intervention, immediately after, and 24 hours after

協力者と研究者

ここでは、この調査に関係する人々や組織を見つけることができます。

スポンサー

出版物と役立つリンク

研究に関する情報を入力する責任者は、自発的にこれらの出版物を提供します。これらは、研究に関連するあらゆるものに関するものである可能性があります。

一般刊行物

  • 1. Hurwitz EL, Randhawa K, Yu H, Cote P, Haldeman S. The global spine care initiative: a summary of the global burden of low back and neck pain studies. Euro Spine Journ. 2018;27(1):796-801. 2. Brown S. Distracted doctoring. Springer Cham; 2017 3. Herzog W. The biomechanics of spinal manipulation. Journ Body and Move Ther. 2010;14(3):280-286. https://doi.org/10.1016/j.jbmt.2010.03.004 4. Olson KA. Manual Physical Therapy of the Spine. Elsevier - Health Science; 2021. 5. Pettman E. A history of manipulative therapy. Journ of Man & Manip Ther. 2007;15(3):165-174. https://doi.org/10.1179/106698107790819873 6. Giacalone A, Febbi M, Magnifica F, Ruberti E. The effect of high velocity low amplitude cervical manipulations on the musculoskeletal system: literature review. Cureus. 2020;12(4). doi: 10.7759/cureus.7682 7. Young IA, Pozzi F, Dunning J, Linkonis R, Michener LA. Immediate and short-term effects of thoracic spine manipulation in patients with cervical radiculopathy: a randomized controlled trial. JOSPT. 2019;49(5):299-309. doi: 10.2519/jospt.2019.8150 8. Reggars JW. The manipulative crack. Journ Chiro Osteo Coll of Aust. 1996;5(2):39-44. doi: 9. Manning A, Butts R, Dunning J. Audible pop during spinal manipulation: plausible mechanisms and clinical relevance. AAMT. June 21, 2016. Accessed October 14, 2024. https://spinalmanipulation.org/2016/06/21/audible-popping-during-spinal-manipulation-plausible-mechanisms-and-clinical-relevance/ 10. Moorman AC. Impact of audible pops associated with spinal manipulation on perceived pain; a systematic review. Chiro and Manual Ther. 2022;30(1). https://doi.org/10.1186/s12998-022-00454-0 11. Smith J, Finnoff JT. Diagnostic and interventional musculoskeletal ultrasound: Part 1. fundamentals. PM&R. 2009;1(1):64-75. https://doi.org/10.1016/j.pmrj.2008.09.001 12. Moreno B, Barbosa J. Ultrasound-guided procedures in the cervical spine. Cureus. 2021. https://doi.org/10.7759/cureus.20361 13. Vasiliadis ES, Grivas TB, Kaspiris A. Histo

研究記録日

これらの日付は、ClinicalTrials.gov への研究記録と要約結果の提出の進捗状況を追跡します。研究記録と報告された結果は、国立医学図書館 (NLM) によって審査され、公開 Web サイトに掲載される前に、特定の品質管理基準を満たしていることが確認されます。

主要日程の研究

研究開始 (実際)

2025年2月4日

一次修了 (実際)

2026年6月1日

研究の完了 (実際)

2026年8月1日

試験登録日

最初に提出

2026年7月10日

QC基準を満たした最初の提出物

2026年7月10日

最初の投稿 (実際)

2026年7月15日

学習記録の更新

投稿された最後の更新 (実際)

2026年8月25日

QC基準を満たした最後の更新が送信されました

2026年8月24日

最終確認日

2026年7月1日

詳しくは

本研究に関する用語

その他の研究ID番号

  • 2025-10 (Istanbul Medipol University Scientific Research Projects Commission)

個々の参加者データ (IPD) の計画

個々の参加者データ (IPD) を共有する予定はありますか?

いいえ

IPD プランの説明

only unidentifiable data will be shared.

医薬品およびデバイス情報、研究文書

米国FDA規制医薬品の研究

いいえ

米国FDA規制機器製品の研究

いいえ

この情報は、Web サイト clinicaltrials.gov から変更なしで直接取得したものです。研究の詳細を変更、削除、または更新するリクエストがある場合は、register@clinicaltrials.gov。 までご連絡ください。 clinicaltrials.gov に変更が加えられるとすぐに、ウェブサイトでも自動的に更新されます。