A Photoplethysmography-Based Machine Learning Algorithm for Early Atrial Fibrillation Detection: A Prospective Validation Study (HeartCore AF)

2026年7月31日 更新者:Seerlinq s. r. o.

Prospective Validation of a Machine-Learning Algorithm Using Photoplethysmography Signals for Early Detection of Atrial Fibrillation During Remote Telemonitoring

This is a prospective study validating a new machine-learning algorithm that detects atrial fibrillation (AF) from photoplethysmography (PPG) signals, developed for integration into the Seerlinq remote monitoring platform. This algorithm builds on the same core PPG signal-processing technology as Seerlinq's HeartCore device, a CE-certified (Class IIb, MDR) device that monitors left ventricular filling pressures in heart failure patients. The algorithm will be validated through internal cross-validation, external validation against an independent cohort with paired PPG-ECG recordings, and validation in a cohort of patients with paroxysmal atrial fibrillation and frequent sinus-AF transitions.

調査の概要

状態

募集

条件

介入・治療

詳細な説明

Atrial fibrillation (AF) and heart failure (HF) frequently coexist and share a bidirectional causal relationship; their concurrence is associated with worse clinical outcomes. Early detection of AF may enable timely intervention and improve outcomes. This study is prospectively validating a machine-learning algorithm for AF detection from PPG signals, intended for integration into the Seerlinq remote monitoring platform. This algorithm builds on the same core PPG signal-processing technology as Seerlinq's HeartCore device (a CE-certified, Class IIb device under the EU MDR that monitors left ventricular filling pressures in heart failure patients). It is a stand-alone algorithm designed specifically to detect clinically relevant (≥ 30s) atrial fibrillation.

Validation of the algorithm will proceed in three stages: (1) internal cross-validation; (2) external validation against an independent cohort with paired PPG-ECG recordings, to confirm generalizability; and (3) validation in a cohort of patients with paroxysmal atrial fibrillation and frequent sinus-AF transitions, to assess performance during clinically challenging rhythm changes.

The study is enrolling toward an estimated 1,000 unique PPG recordings. A 12-lead ECG is used to confirm cardiac rhythm classification (gold standard) as the reference for evaluating algorithm performance.

研究の種類

観察的

入学 (推定)

200

連絡先と場所

このセクションには、調査を実施する担当者の連絡先の詳細と、この調査が実施されている場所に関する情報が記載されています。

研究連絡先

研究場所

      • Bratislava、スロバキア
        • 募集
        • PreMedix
        • コンタクト:
        • 主任研究者:
          • Allan Bohm, M.D., MSc., PhD.

参加基準

研究者は、適格基準と呼ばれる特定の説明に適合する人を探します。これらの基準のいくつかの例は、人の一般的な健康状態または以前の治療です。

適格基準

就学可能な年齢

  • 大人
  • 高齢者

健康ボランティアの受け入れ

いいえ

サンプリング方法

非確率サンプル

調査対象母集団

Adults ≥18 years with a diagnosis of heart failure (HFrEF, HFmrEF, or HFpEF) from Slovakia

説明

Inclusion Criteria:

  • Adults ≥18 years with a diagnosis of heart failure (HFrEF, HFmrEF, or HFpEF)
  • 12-lead ECG performed to confirm cardiac rhythm classification (AF vs. non-AF)

Exclusion Criteria:

  • Missing a valid PPG recording

研究計画

このセクションでは、研究がどのように設計され、研究が何を測定しているかなど、研究計画の詳細を提供します。

研究はどのように設計されていますか?

デザインの詳細

コホートと介入

グループ/コホート
介入・治療
Documented AF
HF patients with a history of permanent/paroxysmal AF and AF documented on 12-lead ECG at enrollment
The PPG-based atrial fibrillation detection algorithm is a non-invasive signal processing approach that analyzes photoplethysmographic waveforms obtained during remote monitoring. The algorithm evaluates pulse-to-pulse variability, waveform characteristics, and signal quality parameters to identify irregular rhythm patterns associated with atrial fibrillation and provide early detection of potential arrhythmic events.
Non-AF
HF patients in sinus rhythm on the index 12-lead ECG with no prior documented AF episodes
The PPG-based atrial fibrillation detection algorithm is a non-invasive signal processing approach that analyzes photoplethysmographic waveforms obtained during remote monitoring. The algorithm evaluates pulse-to-pulse variability, waveform characteristics, and signal quality parameters to identify irregular rhythm patterns associated with atrial fibrillation and provide early detection of potential arrhythmic events.

この研究は何を測定していますか?

主要な結果の測定

結果測定
時間枠
Diagnostic accuracy (area under the ROC curve) of the PPG-based machine-learning algorithm for detecting clinically relevant AF (≥ 30s), compared with gold-standard 12-lead ECG
時間枠:Through study completion (estimated November 2026)
Through study completion (estimated November 2026)

二次結果の測定

結果測定
メジャーの説明
時間枠
Sensitivity and specificity of the algorithm at the Youden-optimal threshold
時間枠:Through study completion (estimated November 2026)
Through study completion (estimated November 2026)
Positive predictive value and negative predictive value
時間枠:Through study completion (estimated November 2026)
Through study completion (estimated November 2026)
Average precision
時間枠:Through study completion (estimated November 2026)
area under the precision-recall curve
Through study completion (estimated November 2026)
Model calibration
時間枠:Through study completion (estimated November 2026)
e.g., calibration curve / Brier score
Through study completion (estimated November 2026)
Matthews correlation coefficient
時間枠:Through study completion (estimated November 2026)
Through study completion (estimated November 2026)
Overall classification accuracy
時間枠:Through study completion (estimated November 2026)
Through study completion (estimated November 2026)
Specificity and false-positive rate in the subgroup with frequent atrial/ventricular extrasystoles
時間枠:Through study completion (estimated November 2026)
Through study completion (estimated November 2026)
Accuracy of AF detection during sinus-AF transitions at the individual patient level
時間枠:Through study completion (estimated November 2026)
Through study completion (estimated November 2026)

協力者と研究者

ここでは、この調査に関係する人々や組織を見つけることができます。

スポンサー

協力者

研究記録日

これらの日付は、ClinicalTrials.gov への研究記録と要約結果の提出の進捗状況を追跡します。研究記録と報告された結果は、国立医学図書館 (NLM) によって審査され、公開 Web サイトに掲載される前に、特定の品質管理基準を満たしていることが確認されます。

主要日程の研究

研究開始 (実際)

2025年10月1日

一次修了 (推定)

2026年8月1日

研究の完了 (推定)

2026年11月1日

試験登録日

最初に提出

2026年7月31日

QC基準を満たした最初の提出物

2026年7月31日

最初の投稿 (実際)

2026年8月6日

学習記録の更新

投稿された最後の更新 (実際)

2026年8月6日

QC基準を満たした最後の更新が送信されました

2026年7月31日

最終確認日

2026年7月1日

詳しくは

本研究に関する用語

その他の研究ID番号

  • HeartCoreAF01

個々の参加者データ (IPD) の計画

個々の参加者データ (IPD) を共有する予定はありますか?

いいえ

IPD プランの説明

The data will not be shared publicly, but anonymized data can be shared upon reasonable request to the corresponding author.

医薬品およびデバイス情報、研究文書

米国FDA規制医薬品の研究

いいえ

米国FDA規制機器製品の研究

いいえ

この情報は、Web サイト clinicaltrials.gov から変更なしで直接取得したものです。研究の詳細を変更、削除、または更新するリクエストがある場合は、register@clinicaltrials.gov。 までご連絡ください。 clinicaltrials.gov に変更が加えられるとすぐに、ウェブサイトでも自動的に更新されます。