Effects of Microelectrode-based Brain Stimulation in Humans (HDBS)
The currently available treatments of Parkinson's disease (PD) and Essential Tremor (ET) are inadequate and accompanied by adverse side effects making the treatment much less effective. This includes treatments with pharmaceuticals as well as electrical brain stimulation (DBS; Deep Brain Stimulation). To address this challenge, we have systematically worked to identify and overcome the shortcomings with current brain stimulation. Essential has been to achieve an understanding of the mechanisms behind the ubiquitous tissue reactions (often referred to as "foreign body reactions"), with loss of nerve cells near implanted electrodes and how to accomplish minimal tissue reactions/damage, which is necessary to enable therapeutically efficient low-intensity stimulation at precise locations. A further challenge relates to individual differences at the level of neuronal networks, making the exact sites in the brain that cause therapeutic and adverse side effects when stimulated not known in advance and thus requiring individual determination. Our strategy has therefore been to develop highly biocompatible microelectrodes (thinner than a human hair and highly flexible) and a guiding investigational device for controlled insertion of a cluster of such microelectrodes in deep target tissue. This enables individualized selection of appropriate stimulation sites. This technique, termed by us "High Definition Brain Stimulation" (HDBS), proved remarkably successful in animal models of both Parkinson's disease and pain by reliably providing powerful symptom relief without noticeable adverse side effects. For this first in human (FIH) investigation of microelectrode-based brain stimulation, we have systematically minimized all identified and foreseeable risks through optimization of the microelectrodes, the design of the investigational device for HDBS and development of simple minimally invasive surgical insertion methods. Extensive monitored safety tests in animals have confirmed the picture of negligeable tissue reactions/damage and absence of bleeding in the target area. Biological safety is also ensured by using only well-established materials documented for chronic implantation in the brain, established sterilization methods, identified safe stimulation intensities, and that the insertion procedures are adapted to well-established precision neurosurgical instruments and routines. The study is an early (FIH) feasibility clinical investigation which will be conducted in up to 12 patients with Parkinson's disease and/or Essential Tremor who are already scheduled for implantation of established DBS. The HDBS device will be inserted into awake patients in the same track as planned for the established DBS electrode. The evaluation will follow a protocol that includes stimulation of predetermined subsets of microelectrodes at up to 4 predetermined levels (depth) in the brain. The stimulation intensity for each subgroup is gradually increased until either a therapeutic effect or an undesirable side effect has been achieved. If an unacceptable effect is elicited, stimulation is immediately interrupted and a new subset of electrodes will be tested. After completion of the evaluation, the HDBS cluster electrode is removed and the implantation of an established permanent DBS electrode is completed. The evaluation will take up to 2.5 hours per patient. The patient's verbal responses, gestures, changes (if any) in tremors, rigidity, speech ability (such as slurring) or facial expressions before, during and after stimulation will be linked to the stimulation parameters (stimulation intensity, subgroup of microelectrodes, depth in the brain and time of reaction) and documented in writing and through video recordings. The analysis will only be made on anonymized data. The primary objective of this early feasibility, FIH, clinical investigation is to clarify whether HDBS (High Definition Brain Stimulation), through individualized stimulation of appropriate subgroups of implanted biocompatible microelectrodes, can provide a powerful therapeutic effect with minimal negative side effects also in humans. In addition, it is intended to simultaneously obtain important information that can be used by the neurosurgeon to improve the subsequent placement of the already scheduled permanent DBS electrode in the individual patient and thereby improve the treatment. Consequently, the secondary objective is to clarify whether HDBS can be used by the neurosurgeon to improve the placement of a permanent DBS electrode. The project paves the way for permanent HDBS with completely new opportunities for powerful, sustainable therapy with minimal side-effects in Parkinson's disease, Essential Tremor and other intractable neurologic disorders. Moreover, the HDBS technology enables new and potent opportunities for brain research.
調査の概要
状態
状態
条件
条件
介入・治療
介入・治療
詳細な説明
The primary objective of this early feasibility clinical investigation is reached if any of the tested subgroups/sites enable powerful therapeutic effects with minimal adverse effects in a patient. A continuous assessment is made as data from different patients accumulate over time to enable an estimation of the success rate.
To address the secondary objective, areas from which appropriate effects are elicited are marked with green and inappropriate areas are marked with red on the last page of the Case Report Form (CRF) for each stimulation depth to provide an overview of the results for each individual patient. This is compared to results obtained from the subsequent evaluation of different contacts on the permanent DBS 3-8 weeks after surgery to assess to what extent the mapping using HDBS can predict DBS outcomes.
研究の種類
研究の種類
入学 (推定)
入学
段階
段階
- 適用できない
連絡先と場所
研究連絡先
研究連絡先
- 名前:Jens Schouenborg, PhD
- 電話番号:+46702924572
- メール:jens.schouenborg@med.lu.se
研究連絡先のバックアップ
- 名前:Hjalmar Bjartmarz, MD
- 電話番号:+46705343055
- メール:hjalmar.bjartmarz@skane.se
研究場所
-
-
Skåne County
-
Lund、Skåne County、スウェーデン、SE-12185
- 募集
- Skane University Hospital
-
コンタクト:
- Hjalmar Bjartmarz, MD
- 電話番号:+46705343055
- メール:hjalmar.bjartmarz@skane.se
-
コンタクト:
- Hakan Widner, MD
- 電話番号:+4646171000
- メール:hakan.widner@skane.se
-
主任研究者:
- Hjalmar Bjartmartz, MD
-
-
参加基準
適格基準
適格基準
就学可能な年齢
健康ボランティアの受け入れ
受講資格のある性別
説明
Inclusion Criteria:
- The target population for the clinical device to be investigated are adult patients with Parkinson's disease or essential tremor that are already scheduled for permanent implantation of devices for deep brain stimulation. This implies that these patients are an already selected group of patients deemed to be appropriate patients for DBS.
- Patients that are fully capable of understanding the patient information.
- Patients that accept to be awake during the investigation
- Patients that accept to be video-filmed during the investigation.
Exclusion Criteria:
- Patients that do not accept to be awake during the stimulation procedure.
- Patients for which the intended extension of surgery time (up to 2,5 hours) is considered by the neurosurgeon to be an unacceptable risk.
- Patients with a known history of blood clotting disorder.
- Patients with a known history of bleeding disorder.
- Patients under age 18.
- Pregnant women and women that are breast feeding.
研究計画
研究はどのように設計されていますか?
デザインの詳細
- 主な目的:処理
- 割り当て:なし
- 介入モデル:単一グループの割り当て
- マスキング:なし(オープンラベル)
アーム数
武器と介入
参加者グループ / アーム参加者グループ / アーム |
介入・治療介入・治療 |
|---|---|
|
実験的:High Definition Brain Stimulation
The investigational device, comprising multiple microelectrodes, will be stereotactically inserted into the brain of awake patients in the same track as planned for the established Deep Brain Stimulation (DBS) electrode. |
The investigational device will be inserted into the brain of awake patients in the same track as planned for the established Deep Brain Stimulation (DBS) electrode. The evaluation will follow a protocol that includes stimulation of predetermined subsets of microelectrodes at up to 4 predetermined levels (depth) in the brain. The stimulation intensity for each subgroup is gradually increased until either a therapeutic effect or an undesirable side effect has been achieved. If an unacceptable effect is elicited, stimulation is immediately interrupted and a new subset of electrodes is tested. After completion of the evaluation, the investigational device will be removed and the implantation of an established permanent DBS electrode is completed. |
この研究は何を測定していますか?
主要な結果の測定
主要な結果の測定
結果測定 |
メジャーの説明 |
時間枠 |
|---|---|---|
|
Changes in motor performance during microelectrode based deep brain stimulation
時間枠:2.5 hours
|
Primary outcome measure is, for each combination of stimulation sites (i.e. subgroup of stimulated microelectrodes), an aggregated outcome measure based on the following components:
For each combination of stimulation sites, the (aggregated) primary outcome measure is either 1 or 0, depending on whether or not a powerful therapeutic effect with minimal unwanted side effects is reached. |
2.5 hours
|
二次結果の測定
二次結果の測定
結果測定 |
メジャーの説明 |
時間枠 |
|---|---|---|
|
Success rate
時間枠:2.5 hours
|
• Number of patients, expressed as percentage of all tested patients, for which it was possible to substantially reduce recorded symptoms with minimal unwanted side effects. |
2.5 hours
|
|
Thresholds for beneficial effects
時間枠:2.5 hours
|
If possible, for each combination of stimulation sites, a threshold expressed in micro-Amps per pulse for at least one of the following effects will be documented: 1) beneficial effects on one symptom, and 2) potent relief of one symptom. If no beneficial effect/potent relief is achieved for a particular combination of stimulation sites this will also be documented. |
2.5 hours
|
|
Aggravation of already existing symptoms
時間枠:2.5 hours
|
Unwanted side effects, consisting in aggravation of existing symptoms by the stimulation. These include increased tremor estimated using ETRS for patients with Essential tremor and worsened PD symptoms (tremor and rigidity) rated using the UPDRS (item III) instrument. Both instruments use a scale from 0 to 4 where a lower score is better. These outcome measures are documented together with stimulation intensity (in micro-Amps) and respective subgroup of microelectrodes used. |
2.5 hours
|
|
Other unwanted side effects for PD and ET patients:
時間枠:2.5 hours
|
Other unwanted side effects than aggravated PD/ET symptoms, such as verbal responses, gestures, slurring of speech, dystonia or facial expressions are documented and scored as zero (score=0), mild (score=1), moderate (score=2) and severe (score=3). These outcome measures of unwanted side-effects are documented together with stimulation intensity (in micro-Amps), respective subgroup of microelectrodes used (i.e. the stimulated brain sites). |
2.5 hours
|
|
Effects of DBS
時間枠:8 hours
|
Recordings of therapeutic and unwanted side effects caused by stimulation of each of the different contacts on the implanted established DBS electrodes 3-8 weeks after surgery. |
8 hours
|
その他の成果指標
その他の成果指標
結果測定 |
メジャーの説明 |
時間枠 |
|---|---|---|
|
Other observations
時間枠:2.5 hours
|
Explorative outcomes: Other observations, such as patient-reported effects on perception, thoughts, emotions during the evaluation, will be documented. |
2.5 hours
|
協力者と研究者
協力者
協力者
捜査官
捜査官
- スタディディレクター:Jens Schouenborg, PhD、Lund University, Lund, Sweden
出版物と役立つリンク
一般刊行物
- Goetz CG, Fahn S, Martinez-Martin P, Poewe W, Sampaio C, Stebbins GT, Stern MB, Tilley BC, Dodel R, Dubois B, Holloway R, Jankovic J, Kulisevsky J, Lang AE, Lees A, Leurgans S, LeWitt PA, Nyenhuis D, Olanow CW, Rascol O, Schrag A, Teresi JA, Van Hilten JJ, LaPelle N. Movement Disorder Society-sponsored revision of the Unified Parkinson's Disease Rating Scale (MDS-UPDRS): Process, format, and clinimetric testing plan. Mov Disord. 2007 Jan;22(1):41-7. doi: 10.1002/mds.21198.
- Fahn S, Tolosa E, Marin C. Clinical rating scale for tremor. In: Jankovic J, Tolosa E, eds. Parkinson's Disease and Movement Disorders. 2nd ed. Baltimore, MD: Williams & Wilkins; 1993:225-234.
研究記録日
主要日程の研究
研究開始 (実際)
研究開始
一次修了 (推定)
一次修了
研究の完了 (推定)
研究の完了
試験登録日
最初に提出
最初に提出
QC基準を満たした最初の提出物
QC基準を満たした最初の提出物
最初の投稿 (実際)
最初の投稿
学習記録の更新
投稿された最後の更新 (実際)
投稿された最後の更新
QC基準を満たした最後の更新が送信されました
QC基準を満たした最後の更新が送信されました
最終確認日
最終確認日
詳しくは
本研究に関する用語
その他の研究ID番号
その他の研究ID番号
- CIV-ID 25-10-054717
個々の参加者データ (IPD) の計画
個々の参加者データ (IPD) を共有する予定はありますか?
IPD プランの説明
Summary data will be made available via ClinicalTrials.gov within 1 year of the study's conclusion.
Individual participant data underlying the results in a publication will be anonymized and will be available with a publication to the extent that they do not allow identification of individual participants. The study is a first in human early feasibility investigation with a small number of participants. This means that only limited individual data can be shared without identifying participants.
IPD 共有時間枠
Summary data will be made available via ClinicalTrials.gov within 1 year of the study's conclusion
医薬品およびデバイス情報、研究文書
米国FDA規制医薬品の研究
米国FDA規制機器製品の研究
この情報は、Web サイト clinicaltrials.gov から変更なしで直接取得したものです。研究の詳細を変更、削除、または更新するリクエストがある場合は、register@clinicaltrials.gov。 までご連絡ください。 clinicaltrials.gov に変更が加えられるとすぐに、ウェブサイトでも自動的に更新されます。