Assessing Blood Pressure Variability in a Healthy Adult Population During Transcutaneous Hypoglossal Nerve Stimulation With the Zeus Sleep Device (Zeus-BPV)
Transcutaneous hypoglossal nerve stimulation is an emerging treatment option for Obstructive Sleep Apnoea (OSA), a sleep condition where breathing is repeatedly limited. The standard treatment for OSA is not always well tolerated therefore, more alternatives are needed.
Transcutaneous hypoglossal nerve stimulation uses a device, such as Zeus, which sticks underneath the chin to deliver electrical pulses during sleep. These pulses stimulate the hypoglossal nerve to prevent the tongue from relaxing and blocking the airway.
Device placement is important for specific nerve targeting; however, its proximity is close to receptors involved in blood pressure regulation. Whilst current research indicates that transcutaneous stimulation is unlikely to increase blood pressure, OSA patients have an increased risk of developing high blood pressure, therefore treatment options should not make this worse. Further research to understand the impact of transcutaneous hypoglossal nerve stimulation on blood pressure is therefore needed. In this study, the blood pressure of participants will be measured whilst they wear the Zeus sleep device. It is expected that blood pressure will either decrease or remain constant in line with current research. Findings could facilitate improved confidence in device use for OSA treatment and provide patients with alternative treatment options.
調査の概要
状態
状態
条件
条件
介入・治療
介入・治療
詳細な説明
During sleep the upper-airway muscles relax, in obstructive sleep apnoea (OSA) this causes repeated narrowing (hypopnoea) and obstruction (apnoea) (NICE, 2021). These periods of reduced breathing cause arousals fragmenting sleep. Symptoms include snoring, impaired performance, waking headaches, and excessive daytime sleepiness (Arnardottir et al., 2016, Spicuzza et al., 2015). OSA additionally impacts quality of life and cognition (Vaessen et al., 2015) and increases risks of hypertension and cardiovascular morbidity (Peppard et al., 2000, Nieto, 2000, Marin et al., 2012). Diagnosis of OSA uses sleep studies, requiring an apnoea hypopnoea index (AHI) of ≥5/hr (NICE, 2021). Peppard et al. (2013) estimate the prevalence of sleep disordered breathing, of which OSA is the most common, to be 26% of 30-70-year-olds and rising.
The gold standard treatment of OSA is continuous positive airway pressure (CPAP) (NICE, 2021), requiring >4hrs/night usage for effective treatment and risk reduction; however, CPAP is not always well tolerated. A review by Weaver et al. (2008) found CPAP nonadherence rates of 29-83%. Alternative treatments include positional modifiers, mandibular advancement devices, and surgery (NICE, 2021, Spicuzza et al., 2015) whose usage is limited by pathophysiology. Further CPAP alternatives are needed.
Hypoglossal nerve stimulation (HNS) is an emerging OSA therapy which uses electrical stimulation to contract the genioglossus muscle, preventing prolapse and maintaining airway patency (NICE, 2017). Strollo et al. (2014) conducted a prospective, single-group, cohort study where non-CPAP compliant OSA patients had a subcutaneous HNS device implanted. A clinically significant decrease in median AHI of 68% (29.3 to 7.4/hr, P<0.001) was seen 12 months post-implantation alongside improved sleepiness and quality of life. A separate study of 113 participants by Woodson et al. (2025) also showed significant improvements in mean AHI (-18.3 ± 11.8/hour, P<0.001) following HNS implantation. Whilst HNS has shown promising efficacy and acceptable safety profile (NICE, 2017, Strollo et al., 2014, Woodson et al. 2025, Friedman et al. 2016), HNS requires a general anaesthesia and carries all the associated risks and costs of an invasive procedure. Interest has therefore turned to transcutaneous HNS as a non-invasive, cost-efficient alternative.
According to Steier et al. (2011), transcutaneous electrical stimulation (TESLA) of the hypoglossal nerve via bilateral hydrogel patches located in the submental area causes contraction of the genioglossus muscle similarly to subcutaneous HNS. A recent randomised controlled trial in OSA patients by Ratneswaran et al., (2023) compared TESLA to usual care (CPAP). An adjusted reduction in AHI of 7/hr with TESLA was seen at 3 months, however this was not significant (P=0.12) potentially due to small sample size or absent additional interrogation. Indeed, Pengo et al. (2016) indicated that only some participants are responders to TESLA, in their randomised, sham-controlled crossover trial a significant reduction in AHI was only seen in responders (9.1/hr, p=0.004). Meta-analysis by Wang et al. (2025) and Young Jae Byun et al. (2020) both concluded that TESLA results in a meaningful AHI reduction. TESLA appears to be well tolerated by patients with minimal adverse events (Pengo et al., 2016, Ratneswaran et al., 2023, Reed et al., 2016).
Despite the promising research, it is possible that submental electrical stimulation could affect blood pressure due to its proximity to carotid sinus baroreceptors. A similar device to TESLA, TENS machines, are contraindicated for use in the neck region (NHS, 2017). However, a sham-controlled, randomized crossover trial of HNS in 60 participants by Dedhia et al., (2023) concluded there was not a significant difference in mean 24-systolic blood pressure between sham and active groups. Furthermore, a study by Alsharifi et al. (2023) found submental TESLA in 13 healthy participants caused a significant decrease in blood pressure (systolic: p=4.93E-06, diastolic: p=3.48E-09, mean: p=3.88E-08); supported by a meta-analysis that concluded electrical stimulation of the upper airways reduced both systolic and diastolic blood pressure (Khaled et al., 2025). Whilst current evidence indicates that TESLA is unlikely to elicit hypertension, in a patient cohort already at increased risk of hypertension and cardiovascular morbidity, it is vital risk is not compounded by treatment.
This study aims to evaluate the short-term impact of hypoglossal nerve TESLA on blood pressure. We hypothesise that submental TESLA will not increase blood pressure or short-term blood pressure variability and may lead to modest reductions, consistent with previous studies.
研究の種類
研究の種類
入学 (推定)
入学
段階
段階
- 適用できない
連絡先と場所
研究連絡先
研究連絡先
- 名前:Abigail Smart
- 電話番号:88910 020 7351 8910
- メール:abigail.smart@nhs.net
研究連絡先のバックアップ
- 名前:Professor Michael Polkey
- メール:mike.polkey@nhs.net
研究場所
-
-
-
London、イギリス、SW3 6NP
- 募集
- Royal Brompton Hospital
-
-
参加基準
適格基準
適格基準
就学可能な年齢
健康ボランティアの受け入れ
受講資格のある性別
説明
Inclusion Criteria:
- Adults aged 18 or older
- Either biological sex
- Healthy volunteers
- Able to provide informed consent
- No contraindications to hypoglossal nerve stimulation using the Zeus device
- BMI >18.5 and <30kg/m2
Exclusion Criteria:
- Skin allergy, including eczema or allergic contact dermatitis in device placement area
- Diagnosed heart condition or cardiovascular disease
- Cardiovascular event in the previous 2 months
- Implanted medical devices including cardioverter defibrillator and pacemaker
- Previous or current cardiac arrhythmia
- Autonomic neuropathy
- Neuromuscular disease
- Diagnosed epilepsy or recurrent seizures
- Hypertension (>140/90 mmHg)
- Hypotension (<95/65 mmHg)
- Metal work in the head or neck, excluding dental fillings
- Current migraine
- Pregnancy
- Diagnosed or suspected deep vein thrombosis within previous 2 months
- Recent cancer diagnosis or cancerous legions in proximity to device placement area
- Alcohol dependence
- Recent infection requiring hospital admission or medical treatment within the previous month, including leprosy
- Swollen, inflamed, infected, or broken skin in device placement area
- Recent surgery within 10 months in, or near, device placement area
- Currently taking medications, excluding contraceptive medication
- Long facial hair in device placement area
研究計画
研究はどのように設計されていますか?
デザインの詳細
- 主な目的:基礎科学
- 割り当て:ランダム化
- 介入モデル:クロスオーバー割り当て
- マスキング:なし(オープンラベル)
アーム数
武器と介入
参加者グループ / アーム参加者グループ / アーム |
介入・治療介入・治療 |
|---|---|
|
実験的:Group 1- Active stimulation followed by sham stimulation
|
Transcutaneous hypoglossal nerve stimulation using the Zeus Sleep device |
|
実験的:Group 2- Sham stimulation followed by active stimulation
|
Transcutaneous hypoglossal nerve stimulation using the Zeus Sleep device |
この研究は何を測定していますか?
主要な結果の測定
主要な結果の測定
結果測定 |
時間枠 |
|---|---|
|
Change from baseline in systolic and diastolic blood pressure during Zeus sleep device usage
時間枠:baseline, intervention
|
baseline, intervention
|
二次結果の測定
二次結果の測定
結果測定 |
時間枠 |
|---|---|
|
Change in pulse rate variability from baseline during active stimulation
時間枠:baseline, intervention
|
baseline, intervention
|
協力者と研究者
研究記録日
主要日程の研究
研究開始 (実際)
研究開始
一次修了 (推定)
一次修了
研究の完了 (推定)
研究の完了
試験登録日
最初に提出
最初に提出
QC基準を満たした最初の提出物
QC基準を満たした最初の提出物
最初の投稿 (実際)
最初の投稿
学習記録の更新
投稿された最後の更新 (実際)
投稿された最後の更新
QC基準を満たした最後の更新が送信されました
QC基準を満たした最後の更新が送信されました
最終確認日
最終確認日
詳しくは
本研究に関する用語
その他の研究ID番号
その他の研究ID番号
- 368532
個々の参加者データ (IPD) の計画
個々の参加者データ (IPD) を共有する予定はありますか?
医薬品およびデバイス情報、研究文書
米国FDA規制医薬品の研究
米国FDA規制機器製品の研究
この情報は、Web サイト clinicaltrials.gov から変更なしで直接取得したものです。研究の詳細を変更、削除、または更新するリクエストがある場合は、register@clinicaltrials.gov。 までご連絡ください。 clinicaltrials.gov に変更が加えられるとすぐに、ウェブサイトでも自動的に更新されます。