このページは自動翻訳されたものであり、翻訳の正確性は保証されていません。を参照してください。 英語版 ソーステキスト用。

Nightly Wearable Monitoring During Home-Based Submental Electrical Stimulation for Obstructive Sleep Apnea

2026年11月2日 更新者:Chih-Chun-Wang、E-DA Hospital

Clinical Testing of a Physiological Signal Detection, Recognition and Feedback System for Obstructive Sleep Apnea: Home-Based Submental Transcutaneous Neuromuscular Electrical Stimulation With Nightly Ring-Type Monitoring

This single-arm pilot study evaluates the feasibility of nightly wearable monitoring with a ring-type sleep monitor during a 4-week home-based program of submental transcutaneous neuromuscular electrical stimulation in adults with obstructive sleep apnea, and describes changes in the ring-derived apnea-hypopnea index, sleep continuity, STOP-Bang score and upper-airway anatomy on CT before and after training.

調査の概要

状態

募集

条件

介入・治療

研究の種類

介入

入学 (推定)

50

段階

  • 適用できない

連絡先と場所

このセクションには、調査を実施する担当者の連絡先の詳細と、この調査が実施されている場所に関する情報が記載されています。

研究場所

      • Kaohsiung City、台湾、82445
        • 募集
        • E-Da Hospital
        • コンタクト:

参加基準

研究者は、適格基準と呼ばれる特定の説明に適合する人を探します。これらの基準のいくつかの例は、人の一般的な健康状態または以前の治療です。

適格基準

就学可能な年齢

20年~65年 (大人、高齢者)

健康ボランティアの受け入れ

いいえ

受講資格のある性別

全て

説明

Inclusion Criteria:

  • Adults aged 20 to 65 years
  • Obstructive sleep apnea diagnosed by a physician on polysomnography or an equivalent respiratory-event index test with AHI >= 5 events/h (mild 5-14.9, moderate 15-29.9, severe >= 30)

Exclusion Criteria:

  • AHI < 5 events/h
  • Pregnancy
  • Prior nasal CPAP therapy
  • Inflammation, rash, broken skin, swelling or infection at the stimulation site
  • Cardiac disease, pacemaker or other implanted electronic or metallic device
  • Allergic reaction to the device
  • Concurrent use of other wearable medical devices (e.g., insulin pump)
  • Cognitive impairment
  • Suspected or confirmed epilepsy
  • Central pain syndromes including headache

研究計画

このセクションでは、研究がどのように設計され、研究が何を測定しているかなど、研究計画の詳細を提供します。

研究はどのように設計されていますか?

デザインの詳細

  • 主な目的:処理
  • 割り当て:なし
  • 介入モデル:単一グループの割り当て
  • マスキング:なし(オープンラベル)

武器と介入

参加者グループ / アーム
介入・治療
実験的:Submental NMES with nightly ring monitoring

Adults with obstructive sleep apnea perform home-based submental transcutaneous neuromuscular electrical stimulation (30 minutes every evening for 28 consecutive nights) and wear a ring-type sleep monitor every night during and after training.

Submental transcutaneous neuromuscular electrical stimulation with the RS-18 wireless low-frequency stimulator (Jie-Mai Medical Technology; TFDA license 007859; off-label use). Biphasic symmetrical pulses, 250 us, 30-100 Hz program, intensity self-titrated to a strong but comfortable contraction. One 30-minute session every evening before bedtime for 28 consecutive nights at home, after supervised instruction.

A ring-type wearable sleep monitor (Belun Ring BLS-100) worn on the finger every night during the 4-week training period to record pulse oximetry, heart rate and accelerometry signals for ring-derived apnea-hypopnea index, oxygen desaturation index and sleep parameters. Used for monitoring only; no therapeutic function.

この研究は何を測定していますか?

主要な結果の測定

結果測定
メジャーの説明
時間枠
Change in Ring-Derived Apnea-Hypopnea Index (bAHI3)
時間枠:Baseline (first 7 nights) and end of training (nights 22-28 or last 7 recordings)

Change in the ring-derived apnea-hypopnea index (bAHI3, events/h) measured by a ring-type sleep monitor (Belun Ring BLS-100), comparing the mean of the first 7 nightly recordings with the mean of the last 7 nightly recordings.

Baseline (first 7 nights) and end of training (nights 22-28 or last 7 recordings)

二次結果の測定

結果測定
メジャーの説明
時間枠
Change in Ring-Derived Apnea-Hypopnea Index Using the 4% Desaturation Criterion (bAHI4)
時間枠:Baseline (first 7 valid nights) and end of training (last 7 valid nights), 4 weeks

Ring-derived apnea-hypopnea index using the 4% oxygen desaturation criterion (bAHI4, events/h) measured by a ring-type sleep monitor (Belun Ring BLS-100), comparing the mean of the first 7 valid nightly recordings with the mean of the last 7 valid nightly recordings.

Baseline (first 7 valid nights) and end of training (last 7 valid nights), 4 weeks
Change in Ring-Derived Sleep Efficiency
時間枠:Baseline (first 7 valid nights) and end of training (last 7 valid nights), 4 weeks

Ring-derived sleep efficiency (%, total sleep time divided by total recording time) measured by a ring-type sleep monitor (Belun Ring BLS-100), comparing the mean of the first 7 valid nightly recordings with the mean of the last 7 valid nightly recordings.

Baseline (first 7 valid nights) and end of training (last 7 valid nights), 4 weeks
Change in STOP-Bang Score
時間枠:Baseline and end of 4-week training

STOP-Bang questionnaire score (range 0-8; higher scores indicate higher risk of obstructive sleep apnea), before vs after training.

Baseline and end of 4-week training
Change in Minimal Nasopharyngeal Cross-Sectional Area on Supine CT
時間枠:Baseline and end of 4-week training

Minimal nasopharyngeal cross-sectional area (mm2) measured on supine computed tomography, before vs after training.

Baseline and end of 4-week training
Post-Training Satisfaction Score
時間枠:End of 4-week training

Participant-rated satisfaction with the training program on a 0-100 scale (higher scores indicate greater satisfaction).

End of 4-week training
Adherence: Proportion of Nights With a Valid Ring Recording
時間枠:4 weeks

Number of nights with a valid ring-type monitor recording divided by the number of scheduled nights, expressed as a percentage.

4 weeks
Number of Participants With Adverse Events
時間枠:During the 4-week training and up to 90 days of follow-up

Adverse events related to electrical stimulation or ring wear (e.g., skin irritation, pain, discomfort), recorded during training and follow-up.

During the 4-week training and up to 90 days of follow-up
Change in Ring-Derived Oxygen Desaturation Index (ODI)
時間枠:Baseline (first 7 valid nights) and end of training (last 7 valid nights), 4 weeks

Ring-derived oxygen desaturation index (events/h) measured by a ring-type sleep monitor (Belun Ring BLS-100), comparing the mean of the first 7 valid nightly recordings with the mean of the last 7 valid nightly recordings.

Baseline (first 7 valid nights) and end of training (last 7 valid nights), 4 weeks
Change in Ring-Derived Sleep-Onset Latency
時間枠:Baseline (first 7 valid nights) and end of training (last 7 valid nights), 4 weeks

Ring-derived sleep-onset latency (min) measured by a ring-type sleep monitor (Belun Ring BLS-100), comparing the mean of the first 7 valid nightly recordings with the mean of the last 7 valid nightly recordings.

Baseline (first 7 valid nights) and end of training (last 7 valid nights), 4 weeks
Change in Ring-Derived Total Sleep Time
時間枠:Baseline (first 7 valid nights) and end of training (last 7 valid nights), 4 weeks

Ring-derived total sleep time (min) measured by a ring-type sleep monitor (Belun Ring BLS-100), comparing the mean of the first 7 valid nightly recordings with the mean of the last 7 valid nightly recordings.

Baseline (first 7 valid nights) and end of training (last 7 valid nights), 4 weeks

協力者と研究者

ここでは、この調査に関係する人々や組織を見つけることができます。

スポンサー

協力者

研究記録日

これらの日付は、ClinicalTrials.gov への研究記録と要約結果の提出の進捗状況を追跡します。研究記録と報告された結果は、国立医学図書館 (NLM) によって審査され、公開 Web サイトに掲載される前に、特定の品質管理基準を満たしていることが確認されます。

主要日程の研究

研究開始 (実際)

2025年6月7日

一次修了 (推定)

2028年1月1日

研究の完了 (推定)

2028年1月1日

試験登録日

最初に提出

2026年11月2日

QC基準を満たした最初の提出物

2026年11月2日

最初の投稿 (実際)

2026年11月6日

学習記録の更新

投稿された最後の更新 (実際)

2026年11月6日

QC基準を満たした最後の更新が送信されました

2026年11月2日

最終確認日

2026年11月1日

詳しくは

本研究に関する用語

その他の研究ID番号

  • AF10-008
  • EMRP37113N (その他の識別子:Institutional Review Board of E-Da Hospital)

個々の参加者データ (IPD) の計画

個々の参加者データ (IPD) を共有する予定はありますか?

未定

IPD プランの説明

De-identified nightly data are available from the corresponding author on reasonable request.

医薬品およびデバイス情報、研究文書

米国FDA規制医薬品の研究

いいえ

米国FDA規制機器製品の研究

いいえ

この情報は、Web サイト clinicaltrials.gov から変更なしで直接取得したものです。研究の詳細を変更、削除、または更新するリクエストがある場合は、register@clinicaltrials.gov。 までご連絡ください。 clinicaltrials.gov に変更が加えられるとすぐに、ウェブサイトでも自動的に更新されます。