Nightly Wearable Monitoring During Home-Based Submental Electrical Stimulation for Obstructive Sleep Apnea
Clinical Testing of a Physiological Signal Detection, Recognition and Feedback System for Obstructive Sleep Apnea: Home-Based Submental Transcutaneous Neuromuscular Electrical Stimulation With Nightly Ring-Type Monitoring
This single-arm pilot study evaluates the feasibility of nightly wearable monitoring with a ring-type sleep monitor during a 4-week home-based program of submental transcutaneous neuromuscular electrical stimulation in adults with obstructive sleep apnea, and describes changes in the ring-derived apnea-hypopnea index, sleep continuity, STOP-Bang score and upper-airway anatomy on CT before and after training.
調査の概要
状態
状態
条件
条件
介入・治療
介入・治療
研究の種類
研究の種類
入学 (推定)
入学
段階
段階
- 適用できない
連絡先と場所
研究場所
-
-
-
Kaohsiung City、台湾、82445
- 募集
- E-Da Hospital
-
コンタクト:
- Chih-Chun Wang
- 電話番号:+886-988-092-216
- メール:CCW5969@yahoo.com.tw
-
-
参加基準
適格基準
適格基準
就学可能な年齢
健康ボランティアの受け入れ
受講資格のある性別
説明
Inclusion Criteria:
- Adults aged 20 to 65 years
- Obstructive sleep apnea diagnosed by a physician on polysomnography or an equivalent respiratory-event index test with AHI >= 5 events/h (mild 5-14.9, moderate 15-29.9, severe >= 30)
Exclusion Criteria:
- AHI < 5 events/h
- Pregnancy
- Prior nasal CPAP therapy
- Inflammation, rash, broken skin, swelling or infection at the stimulation site
- Cardiac disease, pacemaker or other implanted electronic or metallic device
- Allergic reaction to the device
- Concurrent use of other wearable medical devices (e.g., insulin pump)
- Cognitive impairment
- Suspected or confirmed epilepsy
- Central pain syndromes including headache
研究計画
研究はどのように設計されていますか?
デザインの詳細
- 主な目的:処理
- 割り当て:なし
- 介入モデル:単一グループの割り当て
- マスキング:なし(オープンラベル)
アーム数
武器と介入
参加者グループ / アーム参加者グループ / アーム |
介入・治療介入・治療 |
|---|---|
|
実験的:Submental NMES with nightly ring monitoring
Adults with obstructive sleep apnea perform home-based submental transcutaneous neuromuscular electrical stimulation (30 minutes every evening for 28 consecutive nights) and wear a ring-type sleep monitor every night during and after training. |
Submental transcutaneous neuromuscular electrical stimulation with the RS-18 wireless low-frequency stimulator (Jie-Mai Medical Technology; TFDA license 007859; off-label use). Biphasic symmetrical pulses, 250 us, 30-100 Hz program, intensity self-titrated to a strong but comfortable contraction. One 30-minute session every evening before bedtime for 28 consecutive nights at home, after supervised instruction. A ring-type wearable sleep monitor (Belun Ring BLS-100) worn on the finger every night during the 4-week training period to record pulse oximetry, heart rate and accelerometry signals for ring-derived apnea-hypopnea index, oxygen desaturation index and sleep parameters. Used for monitoring only; no therapeutic function. |
この研究は何を測定していますか?
主要な結果の測定
主要な結果の測定
結果測定 |
メジャーの説明 |
時間枠 |
|---|---|---|
|
Change in Ring-Derived Apnea-Hypopnea Index (bAHI3)
時間枠:Baseline (first 7 nights) and end of training (nights 22-28 or last 7 recordings)
|
Change in the ring-derived apnea-hypopnea index (bAHI3, events/h) measured by a ring-type sleep monitor (Belun Ring BLS-100), comparing the mean of the first 7 nightly recordings with the mean of the last 7 nightly recordings. |
Baseline (first 7 nights) and end of training (nights 22-28 or last 7 recordings)
|
二次結果の測定
二次結果の測定
結果測定 |
メジャーの説明 |
時間枠 |
|---|---|---|
|
Change in Ring-Derived Apnea-Hypopnea Index Using the 4% Desaturation Criterion (bAHI4)
時間枠:Baseline (first 7 valid nights) and end of training (last 7 valid nights), 4 weeks
|
Ring-derived apnea-hypopnea index using the 4% oxygen desaturation criterion (bAHI4, events/h) measured by a ring-type sleep monitor (Belun Ring BLS-100), comparing the mean of the first 7 valid nightly recordings with the mean of the last 7 valid nightly recordings. |
Baseline (first 7 valid nights) and end of training (last 7 valid nights), 4 weeks
|
|
Change in Ring-Derived Sleep Efficiency
時間枠:Baseline (first 7 valid nights) and end of training (last 7 valid nights), 4 weeks
|
Ring-derived sleep efficiency (%, total sleep time divided by total recording time) measured by a ring-type sleep monitor (Belun Ring BLS-100), comparing the mean of the first 7 valid nightly recordings with the mean of the last 7 valid nightly recordings. |
Baseline (first 7 valid nights) and end of training (last 7 valid nights), 4 weeks
|
|
Change in STOP-Bang Score
時間枠:Baseline and end of 4-week training
|
STOP-Bang questionnaire score (range 0-8; higher scores indicate higher risk of obstructive sleep apnea), before vs after training. |
Baseline and end of 4-week training
|
|
Change in Minimal Nasopharyngeal Cross-Sectional Area on Supine CT
時間枠:Baseline and end of 4-week training
|
Minimal nasopharyngeal cross-sectional area (mm2) measured on supine computed tomography, before vs after training. |
Baseline and end of 4-week training
|
|
Post-Training Satisfaction Score
時間枠:End of 4-week training
|
Participant-rated satisfaction with the training program on a 0-100 scale (higher scores indicate greater satisfaction). |
End of 4-week training
|
|
Adherence: Proportion of Nights With a Valid Ring Recording
時間枠:4 weeks
|
Number of nights with a valid ring-type monitor recording divided by the number of scheduled nights, expressed as a percentage. |
4 weeks
|
|
Number of Participants With Adverse Events
時間枠:During the 4-week training and up to 90 days of follow-up
|
Adverse events related to electrical stimulation or ring wear (e.g., skin irritation, pain, discomfort), recorded during training and follow-up. |
During the 4-week training and up to 90 days of follow-up
|
|
Change in Ring-Derived Oxygen Desaturation Index (ODI)
時間枠:Baseline (first 7 valid nights) and end of training (last 7 valid nights), 4 weeks
|
Ring-derived oxygen desaturation index (events/h) measured by a ring-type sleep monitor (Belun Ring BLS-100), comparing the mean of the first 7 valid nightly recordings with the mean of the last 7 valid nightly recordings. |
Baseline (first 7 valid nights) and end of training (last 7 valid nights), 4 weeks
|
|
Change in Ring-Derived Sleep-Onset Latency
時間枠:Baseline (first 7 valid nights) and end of training (last 7 valid nights), 4 weeks
|
Ring-derived sleep-onset latency (min) measured by a ring-type sleep monitor (Belun Ring BLS-100), comparing the mean of the first 7 valid nightly recordings with the mean of the last 7 valid nightly recordings. |
Baseline (first 7 valid nights) and end of training (last 7 valid nights), 4 weeks
|
|
Change in Ring-Derived Total Sleep Time
時間枠:Baseline (first 7 valid nights) and end of training (last 7 valid nights), 4 weeks
|
Ring-derived total sleep time (min) measured by a ring-type sleep monitor (Belun Ring BLS-100), comparing the mean of the first 7 valid nightly recordings with the mean of the last 7 valid nightly recordings. |
Baseline (first 7 valid nights) and end of training (last 7 valid nights), 4 weeks
|
協力者と研究者
協力者
協力者
研究記録日
主要日程の研究
研究開始 (実際)
研究開始
一次修了 (推定)
一次修了
研究の完了 (推定)
研究の完了
試験登録日
最初に提出
最初に提出
QC基準を満たした最初の提出物
QC基準を満たした最初の提出物
最初の投稿 (実際)
最初の投稿
学習記録の更新
投稿された最後の更新 (実際)
投稿された最後の更新
QC基準を満たした最後の更新が送信されました
QC基準を満たした最後の更新が送信されました
最終確認日
最終確認日
詳しくは
本研究に関する用語
その他の研究ID番号
その他の研究ID番号
- AF10-008
- EMRP37113N (その他の識別子:Institutional Review Board of E-Da Hospital)
個々の参加者データ (IPD) の計画
個々の参加者データ (IPD) を共有する予定はありますか?
IPD プランの説明
De-identified nightly data are available from the corresponding author on reasonable request.
医薬品およびデバイス情報、研究文書
米国FDA規制医薬品の研究
米国FDA規制機器製品の研究
この情報は、Web サイト clinicaltrials.gov から変更なしで直接取得したものです。研究の詳細を変更、削除、または更新するリクエストがある場合は、register@clinicaltrials.gov。 までご連絡ください。 clinicaltrials.gov に変更が加えられるとすぐに、ウェブサイトでも自動的に更新されます。