このページは自動翻訳されたものであり、翻訳の正確性は保証されていません。を参照してください。 英語版 ソーステキスト用。

Smartphone Versus Back Range of Motion: Validity and Reliability in Lumbar Range of Motion Assessment

2026年6月29日 更新者:Loay Akmal Ali、Cairo University

Clinimetric Properties of Smartphone Application as a Suitable Alternative to Back Range of Motion Device in Assessing the Back Range of Motion

This study aims to investigate the clinimetric properties of the iPhone Level application as a suitable alternative to the Back Range of Motion device in assessing lumbar range of motion, including flexion, extension, and lateral flexion.

調査の概要

詳細な説明

Range of motion measurement is vital in physiotherapy for assessing deficits, establishing diagnoses, and planning interventions. Digital advancements now allow Range of motion assessment through devices and applications, such as the back range of motion, which is a gold standard for measuring lateral flexion due to its validity. Furthermore, studies indicate that the iPhone Level app effectively measures Range of motion in various joints, demonstrating good reliability and validity. This study aims to evaluate the reliability and concurrent validity of the iPhone Level application specifically for measuring lumbar flexion, extension, and side bending Range of motion.

研究の種類

観察的

入学 (実際)

120

連絡先と場所

このセクションには、調査を実施する担当者の連絡先の詳細と、この調査が実施されている場所に関する情報が記載されています。

研究場所

参加基準

研究者は、適格基準と呼ばれる特定の説明に適合する人を探します。これらの基準のいくつかの例は、人の一般的な健康状態または以前の治療です。

適格基準

就学可能な年齢

  • 大人

健康ボランティアの受け入れ

はい

サンプリング方法

確率サンプル

調査対象母集団

Healthy University Students with normal BMI Healthy Male university students

説明

Inclusion Criteria:

  1. Age 18-25 years old
  2. Healthy Male university students
  3. All participants have normal BMI

Exclusion Criteria:

  1. Recent back, pelvic, or abdominal surgeries, traumatic injury to the back .
  2. Lower limb deformities, e.g., leg length discrepancy.
  3. Adolescent idiopathic scoliosis
  4. Any overweight or obese participants

研究計画

このセクションでは、研究がどのように設計され、研究が何を測定しているかなど、研究計画の詳細を提供します。

研究はどのように設計されていますか?

デザインの詳細

この研究は何を測定していますか?

主要な結果の測定

結果測定
メジャーの説明
時間枠
assessment of flexion and extension range of motion using inclinometer
時間枠:at baseline
During lumbar flexion and extension measurements using the Back Range of Motion (BROM) device, patients stand upright with extended knees and feet approximately 17 centimeters apart. For flexion, they bend forward to touch the floor, while for extension, they bend backward with crossed arms. An inclinometer is secured over the sacrum, and its position is centered to record readings in degrees. An L-shaped slide arm measures the distance between the T12 and S1 spinous processes. The device isolates lumbar motion from pelvic motion, and the stationary flexion/extension unit minimizes errors, enhancing measurement accuracy.
at baseline
assessment of lateral flexion range of motion using inclinometer
時間枠:at baseline
For measuring lumbar lateral flexion, the subject's sides are parallel to a wall to prevent compensatory forward trunk flexion. An inclinometer is secured over the sacral region at S1, using a belt for stability. A gravity goniometer is placed on the upper thoracic region to capture trunk angular displacement during side bending. The inclinometer is levelled and zeroed before movement, allowing for precise measurement of lateral lumbar movement while reducing thoracic and pelvic compensations. Accurate placement of the device is essential for reliable results. The subject slides their hand down the thigh, keeping weight on the opposite leg to ensure the measurement reflects true lateral flexion.measures]
at baseline

二次結果の測定

結果測定
メジャーの説明
時間枠
assessment of flexion and extension range of motion using smartphone
時間枠:at baseline
To measure lumbar flexion range of motion (ROM) using the iPhone Level app, participants are positioned standing upright with feet shoulder-width apart. T12-L1 and S1-S2 spinal levels are identified through palpation and marked on the skin. The iPhone is placed at these levels to record angles during maximum lumbar flexion. Total lumbar flexion ROM is calculated by subtracting the angle at S1-S2 from T12-L1. Subjects perform maximum lumbar flexion and extension with straight knees, and measurements are taken across three trials.
at baseline
assessment of lateral flexion range of motion using smartphone
時間枠:at baseline
During the measurement of lumbar side bending using the iPhone Level application, the subject will stand in a neutral upright position with feet shoulder-width apart and hands placed on the hips to prevent arm movement from influencing the measurement. The spinous processes of T12 and S2 are identified and marked on the skin. The iPhone is first placed and zeroed at the T12 level, and the subject is instructed to bend sideways (toward one side) as far as possible without lifting the heels or rotating the trunk. The device remains aligned at T12 to capture the angular displacement. The same procedure is repeated with the device positioned at S2, and the final lumbar side bending range of motion is calculated by subtracting the angle at S2 (pelvic movement) from that at T12 (trunk movement). This method isolates lumbar lateral flexion and has shown good reliability and validity in clinical settings
at baseline

協力者と研究者

ここでは、この調査に関係する人々や組織を見つけることができます。

研究記録日

これらの日付は、ClinicalTrials.gov への研究記録と要約結果の提出の進捗状況を追跡します。研究記録と報告された結果は、国立医学図書館 (NLM) によって審査され、公開 Web サイトに掲載される前に、特定の品質管理基準を満たしていることが確認されます。

主要日程の研究

研究開始 (実際)

2025年12月1日

一次修了 (実際)

2026年3月1日

研究の完了 (実際)

2026年5月12日

試験登録日

最初に提出

2026年6月14日

QC基準を満たした最初の提出物

2026年6月29日

最初の投稿 (実際)

2026年7月2日

学習記録の更新

投稿された最後の更新 (実際)

2026年7月2日

QC基準を満たした最後の更新が送信されました

2026年6月29日

最終確認日

2026年6月1日

詳しくは

本研究に関する用語

追加の関連 MeSH 用語

その他の研究ID番号

  • P.T.REC/012/006199

個々の参加者データ (IPD) の計画

個々の参加者データ (IPD) を共有する予定はありますか?

いいえ

医薬品およびデバイス情報、研究文書

米国FDA規制医薬品の研究

いいえ

米国FDA規制機器製品の研究

いいえ

この情報は、Web サイト clinicaltrials.gov から変更なしで直接取得したものです。研究の詳細を変更、削除、または更新するリクエストがある場合は、register@clinicaltrials.gov。 までご連絡ください。 clinicaltrials.gov に変更が加えられるとすぐに、ウェブサイトでも自動的に更新されます。

購読する