Smartphone Versus Back Range of Motion: Validity and Reliability in Lumbar Range of Motion Assessment

29 giugno 2026 aggiornato da: Loay Akmal Ali, Cairo University

Clinimetric Properties of Smartphone Application as a Suitable Alternative to Back Range of Motion Device in Assessing the Back Range of Motion

This study aims to investigate the clinimetric properties of the iPhone Level application as a suitable alternative to the Back Range of Motion device in assessing lumbar range of motion, including flexion, extension, and lateral flexion.

Panoramica dello studio

Descrizione dettagliata

Range of motion measurement is vital in physiotherapy for assessing deficits, establishing diagnoses, and planning interventions. Digital advancements now allow Range of motion assessment through devices and applications, such as the back range of motion, which is a gold standard for measuring lateral flexion due to its validity. Furthermore, studies indicate that the iPhone Level app effectively measures Range of motion in various joints, demonstrating good reliability and validity. This study aims to evaluate the reliability and concurrent validity of the iPhone Level application specifically for measuring lumbar flexion, extension, and side bending Range of motion.

Tipo di studio

Osservativo

Iscrizione (Effettivo)

120

Contatti e Sedi

Questa sezione fornisce i recapiti di coloro che conducono lo studio e informazioni su dove viene condotto lo studio.

Luoghi di studio

      • Giza, Egitto, 12613
        • Cairo University

Criteri di partecipazione

I ricercatori cercano persone che corrispondano a una certa descrizione, chiamata criteri di ammissibilità. Alcuni esempi di questi criteri sono le condizioni generali di salute di una persona o trattamenti precedenti.

Criteri di ammissibilità

Età idonea allo studio

  • Adulto

Accetta volontari sani

Metodo di campionamento

Campione di probabilità

Popolazione di studio

Healthy University Students with normal BMI Healthy Male university students

Descrizione

Inclusion Criteria:

  1. Age 18-25 years old
  2. Healthy Male university students
  3. All participants have normal BMI

Exclusion Criteria:

  1. Recent back, pelvic, or abdominal surgeries, traumatic injury to the back .
  2. Lower limb deformities, e.g., leg length discrepancy.
  3. Adolescent idiopathic scoliosis
  4. Any overweight or obese participants

Piano di studio

Questa sezione fornisce i dettagli del piano di studio, compreso il modo in cui lo studio è progettato e ciò che lo studio sta misurando.

Come è strutturato lo studio?

Dettagli di progettazione

Cosa sta misurando lo studio?

Misure di risultato primarie

Misura del risultato
Misura Descrizione
Lasso di tempo
assessment of flexion and extension range of motion using inclinometer
Lasso di tempo: at baseline
During lumbar flexion and extension measurements using the Back Range of Motion (BROM) device, patients stand upright with extended knees and feet approximately 17 centimeters apart. For flexion, they bend forward to touch the floor, while for extension, they bend backward with crossed arms. An inclinometer is secured over the sacrum, and its position is centered to record readings in degrees. An L-shaped slide arm measures the distance between the T12 and S1 spinous processes. The device isolates lumbar motion from pelvic motion, and the stationary flexion/extension unit minimizes errors, enhancing measurement accuracy.
at baseline
assessment of lateral flexion range of motion using inclinometer
Lasso di tempo: at baseline
For measuring lumbar lateral flexion, the subject's sides are parallel to a wall to prevent compensatory forward trunk flexion. An inclinometer is secured over the sacral region at S1, using a belt for stability. A gravity goniometer is placed on the upper thoracic region to capture trunk angular displacement during side bending. The inclinometer is levelled and zeroed before movement, allowing for precise measurement of lateral lumbar movement while reducing thoracic and pelvic compensations. Accurate placement of the device is essential for reliable results. The subject slides their hand down the thigh, keeping weight on the opposite leg to ensure the measurement reflects true lateral flexion.measures]
at baseline

Misure di risultato secondarie

Misura del risultato
Misura Descrizione
Lasso di tempo
assessment of flexion and extension range of motion using smartphone
Lasso di tempo: at baseline
To measure lumbar flexion range of motion (ROM) using the iPhone Level app, participants are positioned standing upright with feet shoulder-width apart. T12-L1 and S1-S2 spinal levels are identified through palpation and marked on the skin. The iPhone is placed at these levels to record angles during maximum lumbar flexion. Total lumbar flexion ROM is calculated by subtracting the angle at S1-S2 from T12-L1. Subjects perform maximum lumbar flexion and extension with straight knees, and measurements are taken across three trials.
at baseline
assessment of lateral flexion range of motion using smartphone
Lasso di tempo: at baseline
During the measurement of lumbar side bending using the iPhone Level application, the subject will stand in a neutral upright position with feet shoulder-width apart and hands placed on the hips to prevent arm movement from influencing the measurement. The spinous processes of T12 and S2 are identified and marked on the skin. The iPhone is first placed and zeroed at the T12 level, and the subject is instructed to bend sideways (toward one side) as far as possible without lifting the heels or rotating the trunk. The device remains aligned at T12 to capture the angular displacement. The same procedure is repeated with the device positioned at S2, and the final lumbar side bending range of motion is calculated by subtracting the angle at S2 (pelvic movement) from that at T12 (trunk movement). This method isolates lumbar lateral flexion and has shown good reliability and validity in clinical settings
at baseline

Collaboratori e investigatori

Qui è dove troverai le persone e le organizzazioni coinvolte in questo studio.

Studiare le date dei record

Queste date tengono traccia dell'avanzamento della registrazione dello studio e dell'invio dei risultati di sintesi a ClinicalTrials.gov. I record degli studi e i risultati riportati vengono esaminati dalla National Library of Medicine (NLM) per assicurarsi che soddisfino specifici standard di controllo della qualità prima di essere pubblicati sul sito Web pubblico.

Studia le date principali

Inizio studio (Effettivo)

1 dicembre 2025

Completamento primario (Effettivo)

1 marzo 2026

Completamento dello studio (Effettivo)

12 maggio 2026

Date di iscrizione allo studio

Primo inviato

14 giugno 2026

Primo inviato che soddisfa i criteri di controllo qualità

29 giugno 2026

Primo Inserito (Effettivo)

2 luglio 2026

Aggiornamenti dei record di studio

Ultimo aggiornamento pubblicato (Effettivo)

2 luglio 2026

Ultimo aggiornamento inviato che soddisfa i criteri QC

29 giugno 2026

Ultimo verificato

1 giugno 2026

Maggiori informazioni

Termini relativi a questo studio

Termini MeSH pertinenti aggiuntivi

Altri numeri di identificazione dello studio

  • P.T.REC/012/006199

Piano per i dati dei singoli partecipanti (IPD)

Hai intenzione di condividere i dati dei singoli partecipanti (IPD)?

NO

Informazioni su farmaci e dispositivi, documenti di studio

Studia un prodotto farmaceutico regolamentato dalla FDA degli Stati Uniti

No

Studia un dispositivo regolamentato dalla FDA degli Stati Uniti

No

Queste informazioni sono state recuperate direttamente dal sito web clinicaltrials.gov senza alcuna modifica. In caso di richieste di modifica, rimozione o aggiornamento dei dettagli dello studio, contattare register@clinicaltrials.gov. Non appena verrà implementata una modifica su clinicaltrials.gov, questa verrà aggiornata automaticamente anche sul nostro sito web .

Prove cliniche su Sindrome del dolore lombare

Prove cliniche su easement tool 1 - BROM device

3
Sottoscrivi