Smartphone Versus Back Range of Motion: Validity and Reliability in Lumbar Range of Motion Assessment
2026. június 29. frissítette: Loay Akmal Ali, Cairo University
Clinimetric Properties of Smartphone Application as a Suitable Alternative to Back Range of Motion Device in Assessing the Back Range of Motion
This study aims to investigate the clinimetric properties of the iPhone Level application as a suitable alternative to the Back Range of Motion device in assessing lumbar range of motion, including flexion, extension, and lateral flexion.
A tanulmány áttekintése
Állapot
Befejezve
Körülmények
Beavatkozás / kezelés
Részletes leírás
Range of motion measurement is vital in physiotherapy for assessing deficits, establishing diagnoses, and planning interventions.
Digital advancements now allow Range of motion assessment through devices and applications, such as the back range of motion, which is a gold standard for measuring lateral flexion due to its validity.
Furthermore, studies indicate that the iPhone Level app effectively measures Range of motion in various joints, demonstrating good reliability and validity.
This study aims to evaluate the reliability and concurrent validity of the iPhone Level application specifically for measuring lumbar flexion, extension, and side bending Range of motion.
Tanulmány típusa
Megfigyelő
Beiratkozás (Tényleges)
120
Kapcsolatok és helyek
Ez a rész a vizsgálatot végzők elérhetőségeit, valamint a vizsgálat lefolytatásának helyére vonatkozó információkat tartalmazza.
Tanulmányi helyek
-
-
-
Giza, Egyiptom, 12613
- Cairo University
-
-
Részvételi kritériumok
A kutatók olyan embereket keresnek, akik megfelelnek egy bizonyos leírásnak, az úgynevezett jogosultsági kritériumoknak. Néhány példa ezekre a kritériumokra a személy általános egészségi állapota vagy a korábbi kezelések.
Jogosultsági kritériumok
Tanulmányozható életkorok
- Felnőtt
Egészséges önkénteseket fogad
Igen
Mintavételi módszer
Valószínűségi minta
Tanulmányi populáció
Healthy University Students with normal BMI Healthy Male university students
Leírás
Inclusion Criteria:
- Age 18-25 years old
- Healthy Male university students
- All participants have normal BMI
Exclusion Criteria:
- Recent back, pelvic, or abdominal surgeries, traumatic injury to the back .
- Lower limb deformities, e.g., leg length discrepancy.
- Adolescent idiopathic scoliosis
- Any overweight or obese participants
Tanulási terv
Ez a rész a vizsgálati terv részleteit tartalmazza, beleértve a vizsgálat megtervezését és a vizsgálat mérését.
Hogyan készül a tanulmány?
Tervezési részletek
Mit mér a tanulmány?
Elsődleges eredményintézkedések
Eredménymérő |
Intézkedés leírása |
Időkeret |
|---|---|---|
|
assessment of flexion and extension range of motion using inclinometer
Időkeret: at baseline
|
During lumbar flexion and extension measurements using the Back Range of Motion (BROM) device, patients stand upright with extended knees and feet approximately 17 centimeters apart.
For flexion, they bend forward to touch the floor, while for extension, they bend backward with crossed arms.
An inclinometer is secured over the sacrum, and its position is centered to record readings in degrees.
An L-shaped slide arm measures the distance between the T12 and S1 spinous processes.
The device isolates lumbar motion from pelvic motion, and the stationary flexion/extension unit minimizes errors, enhancing measurement accuracy.
|
at baseline
|
|
assessment of lateral flexion range of motion using inclinometer
Időkeret: at baseline
|
For measuring lumbar lateral flexion, the subject's sides are parallel to a wall to prevent compensatory forward trunk flexion.
An inclinometer is secured over the sacral region at S1, using a belt for stability.
A gravity goniometer is placed on the upper thoracic region to capture trunk angular displacement during side bending.
The inclinometer is levelled and zeroed before movement, allowing for precise measurement of lateral lumbar movement while reducing thoracic and pelvic compensations.
Accurate placement of the device is essential for reliable results.
The subject slides their hand down the thigh, keeping weight on the opposite leg to ensure the measurement reflects true lateral flexion.measures]
|
at baseline
|
Másodlagos eredményintézkedések
Eredménymérő |
Intézkedés leírása |
Időkeret |
|---|---|---|
|
assessment of flexion and extension range of motion using smartphone
Időkeret: at baseline
|
To measure lumbar flexion range of motion (ROM) using the iPhone Level app, participants are positioned standing upright with feet shoulder-width apart.
T12-L1 and S1-S2 spinal levels are identified through palpation and marked on the skin.
The iPhone is placed at these levels to record angles during maximum lumbar flexion.
Total lumbar flexion ROM is calculated by subtracting the angle at S1-S2 from T12-L1.
Subjects perform maximum lumbar flexion and extension with straight knees, and measurements are taken across three trials.
|
at baseline
|
|
assessment of lateral flexion range of motion using smartphone
Időkeret: at baseline
|
During the measurement of lumbar side bending using the iPhone Level application, the subject will stand in a neutral upright position with feet shoulder-width apart and hands placed on the hips to prevent arm movement from influencing the measurement.
The spinous processes of T12 and S2 are identified and marked on the skin.
The iPhone is first placed and zeroed at the T12 level, and the subject is instructed to bend sideways (toward one side) as far as possible without lifting the heels or rotating the trunk.
The device remains aligned at T12 to capture the angular displacement.
The same procedure is repeated with the device positioned at S2, and the final lumbar side bending range of motion is calculated by subtracting the angle at S2 (pelvic movement) from that at T12 (trunk movement).
This method isolates lumbar lateral flexion and has shown good reliability and validity in clinical settings
|
at baseline
|
Együttműködők és nyomozók
Itt találhatja meg a tanulmányban érintett személyeket és szervezeteket.
Szponzor
Együttműködők
Tanulmányi rekorddátumok
Ezek a dátumok nyomon követik a ClinicalTrials.gov webhelyre benyújtott vizsgálati rekordok és összefoglaló eredmények benyújtásának folyamatát. A vizsgálati feljegyzéseket és a jelentett eredményeket a Nemzeti Orvostudományi Könyvtár (NLM) felülvizsgálja, hogy megbizonyosodjon arról, hogy megfelelnek-e az adott minőség-ellenőrzési szabványoknak, mielőtt közzéteszik őket a nyilvános weboldalon.
Tanulmány főbb dátumok
Tanulmány kezdete (Tényleges)
2025. december 1.
Elsődleges befejezés (Tényleges)
2026. március 1.
A tanulmány befejezése (Tényleges)
2026. május 12.
Tanulmányi regisztráció dátumai
Először benyújtva
2026. június 14.
Először nyújtották be, amely megfelel a minőségbiztosítási kritériumoknak
2026. június 29.
Első közzététel (Tényleges)
2026. július 2.
Tanulmányi rekordok frissítései
Utolsó frissítés közzétéve (Tényleges)
2026. július 2.
Az utolsó frissítés elküldve, amely megfelel a minőségbiztosítási kritériumoknak
2026. június 29.
Utolsó ellenőrzés
2026. június 1.
Több információ
A tanulmányhoz kapcsolódó kifejezések
További vonatkozó MeSH feltételek
Egyéb vizsgálati azonosító számok
- P.T.REC/012/006199
Terv az egyéni résztvevői adatokhoz (IPD)
Tervezi megosztani az egyéni résztvevői adatokat (IPD)?
NEM
Gyógyszer- és eszközinformációk, tanulmányi dokumentumok
Egy amerikai FDA által szabályozott gyógyszerkészítményt tanulmányoz
Nem
Egy amerikai FDA által szabályozott eszközterméket tanulmányoz
Nem
Ezt az információt közvetlenül a clinicaltrials.gov webhelyről szereztük be, változtatás nélkül. Ha bármilyen kérése van vizsgálati adatainak módosítására, eltávolítására vagy frissítésére, kérjük, írjon a következő címre: register@clinicaltrials.gov. Amint a változás bevezetésre kerül a clinicaltrials.gov oldalon, ez a webhelyünkön is automatikusan frissül. .