이 페이지는 자동 번역되었으며 번역의 정확성을 보장하지 않습니다. 참조하십시오 영문판 원본 텍스트의 경우.

체중 부하 CT 삽입물 주위 원위 무릎 골절

체중부하 CT를 이용한 삽입물 주위 골절 치료 후 부하에 따른 뼈 변위 평가

Total knee arthroplasty (TKA), a knee implant surgery, is a treatment for end-stage knee osteoarthritis. In some cases, patients suffer an associated periprosthetic fracture, a broken bone that occurs around the implant of a TKA, they may not receive excellent care due to a lack of a trustworthy assessments for fracture healing in the research world. The prevalence of TKA surgeries is increasing annually and is expected to increase further due to an ageing population and obesity issue. By extension to this primary surgery, more Canadians will require an invasive revision surgery that risks patient morbidity and mortality. Thus, it is important to set a standard for fracture stabilization and bone healing assessments to lessen revision burdens and improve patient outcomes. CT imaging is the main clinical tool to evaluate implant stabilization in TKA, which can effectively visualize areas of incomplete bone ingrowth, bone growing into the implant, that may be hidden from overlapping bone and muscle tissue on plain x-rays. The purpose of this prospective study is to examine the efficacy of weight-bearing CT as a diagnostic tool for 21 participants who experienced a distal femur periprosthetic fracture and have underwent revision surgery using a fracture fixation plate and screws, internal splints that hold the bone pieces together. Participants will be scanned under loaded (applying weight on limb) and unloaded conditions. Radiographic outcomes, x-ray imaging from the weight-bearing CT, will be evaluated, including any movement of the bone segments and how they would relate to participants' reports of pain.

연구 개요

상태

모병

정황

개입 / 치료

상세 설명

Total knee arthroplasty is the most cost-effective and successful treatment for knee joints with end-stage osteoarthritis, with more than 58,000 TKA surgeries in Canada in 2021-2022.1 The prevalence of TKA surgeries is increasing per year and is projected to rise due to an ageing population and obesity problems.1 In addition to the primary surgery, more than 4,000 Canadians require revision TKA surgery per year; the TKA revision burden is estimated to reach $13 billion by 2030 as a consequence of a substantial increase of 149% in primary surgeries by 2030 in the United States.1-3 Revision surgery is more invasive than primary surgery and poses the risk of increasing patient mortality rates, especially for older adults.3 Thus, it is imperative for surgeons to make an appropriate radiographic diagnosis of implant fixation and/or fracture healing, but many cases remain challenging to diagnose.4

In the orthopaedic literature, there is no consensus on a reliable definition criterion for long-bone non-unions, making the standardization of diagnoses difficult; the lack of a trustworthy assessment for component fixation and fracture healing can lead to patients receiving sub-optimal care.5 This can also limit the collection of evidence supporting the use of specific implant components, surgical techniques, and post-operative activity guidelines. Moreover, comparing healing results of different clinical studies for long-bone non-unions can become problematic due to different criteria being used.5 Radiographic features associated with loosening such as radiolucencies are often only appreciable for the cement-bone interface, rather than the cement-implant interface which is the most common site of failure causing loosening.4 Failure to properly diagnose fracture non-union leaves patients in pain with substantial morbidity, while unnecessary surgery risks significant complication. Given the increasing rates of TKA and associated predictions of increasing revision burden,6 along with ongoing debates over the superiority of certain implants or surgical techniques, there is an unmet need for better fixation and bone healing assessment.

Historically, radiostereometric analysis (RSA) has been the gold standard for measuring implant fixation.7 However, it remains a niche tool limited to clinical research because of its requirement for implanted marker beads and specialized equipment being accessible for a handful of labs in North America.7-8 Recently, multiple groups have developed approaches to perform RSA-like measurements using clinical CT scans for shoulder, hip, and knee replacements.9 The accuracy and precision of the "CT-RSA" methods are on par with conventional RSA and acceptable for clinical studies.10-15 It is predicted that there will be a greater uptake of CT-RSA than conventional RSA, but the technology is still in its infancy.9 The application of CT-RSA will undoubtedly be more inclusive as examinations can now be performed on patients who did not have marker beads implanted at the time of their original surgery, and CAD models of implants are not needed.16 Using a weight-bearing CT scanner is the most similar implementation of CT-RSA to conventional RSA, as exams can be acquired in unloaded and loaded positions.

Additionally, in the field of microbiome research, the gut microbiome is being investigated for its potential impacts on bone health and recovery. There are currently a few studies that have linked the intestinal microbiome having a beneficiary effect to fracture healing with a new concept referred to as the gut-bone axis.17 Moreover, the gut microbiome of patients with poor bone quality has previously been found to be altered.18 We will use stool samples to assess gut microbiome composition to see if patients with markers for poor bone quality could have increased migration.

The results of this proposed study will demonstrate the ability to precisely measure displacements between bone segments under loading following periprosthetic fracture repair with weight-bearing. These will be the first-ever measurements of distal femur periprosthetic fracture healing with weight-bearing CT-RSA. Demonstration of this will enable us to pursue future studies that are prospective in nature and may evaluate topics such as time to weight-bearing activities, different types of surgical reconstructions, and relationship between healing and bone quality/bone health. Other centres with access to weight-bearing CT will also benefit from this work. Usage of the weight-bearing CT may improve the generalizability of this approach and support it as a clinical diagnostic tool. For example, surgeons may better understand bone fragment motion over time and recommend appropriate postoperative activities for patients' weight-bearing tolerance. Therefore, the proposed study design will evaluate the ability to perform inducible displacement measurements following the surgical repair of distal femur periprosthetic fractures using weight-bearing CT.

연구 유형

중재적

등록 (추정된)

21

단계

  • 해당 없음

연락처 및 위치

이 섹션에서는 연구를 수행하는 사람들의 연락처 정보와 이 연구가 수행되는 장소에 대한 정보를 제공합니다.

연구 연락처

연구 연락처 백업

연구 장소

    • Ontario
      • London, Ontario, 캐나다, N6A5A5

참여기준

연구원은 적격성 기준이라는 특정 설명에 맞는 사람을 찾습니다. 이러한 기준의 몇 가지 예는 개인의 일반적인 건강 상태 또는 이전 치료입니다.

자격 기준

공부할 수 있는 나이

50년 (성인, 고령자)

건강한 자원 봉사자를 받아들입니다

아니

연구 대상 성별

모두

설명

Inclusion Criteria:

  • Recently underwent revision surgery for repair of a distal femur fracture surgery for total knee arthroplasty femoral component using a fracture fixation plate. Due to the study requiring the potential participant to be scanned <1-week post-operation, the duration of "recently" will be defined as <1 week post-operation.
  • Age 50-90 years
  • Body mass index up to 40kg/m2
  • Able to provide informed consent
  • Able and willing to do study assessments and follow instructions

Exclusion Criteria:

  • Prior revision surgery on the targeted knee
  • Does not understand English
  • Undergoing and/or have undergone revision surgery for any other indication
  • Received intramedullary nail or distal femur replacement
  • Cannot independently stand on one leg in the weight-bearing CT during the inducible displacement exam

공부 계획

이 섹션에서는 연구 설계 방법과 연구가 측정하는 내용을 포함하여 연구 계획에 대한 세부 정보를 제공합니다.

연구는 어떻게 설계됩니까?

디자인 세부사항

  • 주 목적: 다른
  • 할당: 해당 없음
  • 중재 모델: 단일 그룹 할당
  • 마스킹: 없음(오픈 라벨)

무기와 개입

참가자 그룹 / 팔
개입 / 치료
실험적: Periprosthetic Fracture Knee Repaired

The one and only group will be participants that have recently undergone revision surgery for their periprosthetic distal knee fracture.

We will be assessing the use of weight-bearing CT, specifically its imaging, with RSA-like software, for analyzing fracture healing over time for a periprosthetic distal knee fracture.

연구는 무엇을 측정합니까?

주요 결과 측정

결과 측정
측정값 설명
기간
Weight-Bearing CT Scans
기간: Scans obtained: 1-year

Weight-bearing CT scans of the periprosthetic distal knee fracture that has undergone revision surgery

Scans obtained: 1-year
Pain and Function Questionnaires
기간: <1-week post-operation, 6 weeks, and 1-year

Pain and function questionnaires that assess the pain and ability-to-function of the knee. These are participant-reported outcomes and they will be compared to the CT scans

<1-week post-operation, 6 weeks, and 1-year

2차 결과 측정

결과 측정
측정값 설명
기간
Stool sample
기간: 6-week timepoint post-operation

Stool sample collected from participant and analyzed and compared to CT scans for bone healing assessments.

6-week timepoint post-operation

공동 작업자 및 조사자

여기에서 이 연구와 관련된 사람과 조직을 찾을 수 있습니다.

스폰서

수사관

  • 수석 연구원: Brent Lanting, MD, London Health Sciences Centre
  • 연구 의자: Lyndsay Somerville, PhD, London Health Sciences Centre
  • 연구 의자: James Howard, MD, London Health Sciences Centre
  • 연구 책임자: Matthew Teeter, PhD, London Health Sciences Centre Research Institute OR Lawson Research Institute of St. Joseph's

간행물 및 유용한 링크

연구에 대한 정보 입력을 담당하는 사람이 자발적으로 이러한 간행물을 제공합니다. 이것은 연구와 관련된 모든 것에 관한 것일 수 있습니다.

일반 간행물

연구 기록 날짜

이 날짜는 ClinicalTrials.gov에 대한 연구 기록 및 요약 결과 제출의 진행 상황을 추적합니다. 연구 기록 및 보고된 결과는 공개 웹사이트에 게시되기 전에 특정 품질 관리 기준을 충족하는지 확인하기 위해 국립 의학 도서관(NLM)에서 검토합니다.

연구 주요 날짜

연구 시작 (실제)

2025년 9월 24일

기본 완료 (추정된)

2027년 8월 1일

연구 완료 (추정된)

2027년 8월 1일

연구 등록 날짜

최초 제출

2024년 7월 24일

QC 기준을 충족하는 최초 제출

2024년 7월 24일

처음 게시됨 (실제)

2024년 7월 29일

연구 기록 업데이트

마지막 업데이트 게시됨 (실제)

2026년 9월 29일

QC 기준을 충족하는 마지막 업데이트 제출

2026년 9월 24일

마지막으로 확인됨

2026년 9월 1일

추가 정보

이 연구와 관련된 용어

기타 연구 ID 번호

  • 14177

개별 참가자 데이터(IPD) 계획

개별 참가자 데이터(IPD)를 공유할 계획입니까?

미정

약물 및 장치 정보, 연구 문서

미국 FDA 규제 의약품 연구

아니

미국 FDA 규제 기기 제품 연구

아니

이 정보는 변경 없이 clinicaltrials.gov 웹사이트에서 직접 가져온 것입니다. 귀하의 연구 세부 정보를 변경, 제거 또는 업데이트하도록 요청하는 경우 register@clinicaltrials.gov. 문의하십시오. 변경 사항이 clinicaltrials.gov에 구현되는 즉시 저희 웹사이트에도 자동으로 업데이트됩니다. .