Carpal tunnel syndrome (CTS) is the most common entrapment neuropathy of the upper extremity and is characterized by pain, paresthesia, and functional impairment resulting from increased pressure within the carpal tunnel. Although conservative treatment approaches such as splinting and pharmacological therapy are commonly used, High-Intensity Laser Therapy (HILT) has emerged as a non-invasive modality with potential analgesic, anti-inflammatory, and biostimulatory effects. However, evidence regarding its efficacy remains limited, particularly from sham-controlled studies incorporating objective outcome measures. This prospective, randomized, double-blind, sham-controlled clinical trial aims to evaluate the clinical, sonographic, and electrophysiological effectiveness of HILT in patients with mild-to-moderate CTS. Eligible patients aged 18 to 65 years with electrophysiologically confirmed mild-to-moderate CTS will be randomized into two groups: a HILT group and a sham HILT group. Both groups will receive standard wrist splinting as part of conservative management. Clinical outcomes will be assessed using Visual Analog Scale (VAS) scores for pain, Boston Carpal Tunnel Questionnaire (BCTQ) scores for symptom severity and functional status, and grip strength measurements. Objective evaluations will include median nerve sensory and motor nerve conduction studies and ultrasonographic measurement of the median nerve cross-sectional area at the proximal carpal tunnel level. Assessments will be performed at baseline and at 1 and 3 months after treatment. This study aims to provide robust and objective evidence regarding the therapeutic effectiveness of HILT in the conservative management of carpal tunnel syndrome.

연구 개요

상태

완전한

정황

개입 / 치료

상세 설명

Carpal Tunnel Syndrome (CTS) is the most common entrapment neuropathy of the upper extremity, characterized by the compression of the median nerve due to increased pressure within the carpal tunnel. While conservative management strategies such as splinting and physical therapy modalities are the standard approach, High-Intensity Laser Therapy (HILT) has recently emerged as a potent, non-invasive therapeutic option . Utilizing an Nd:YAG laser source, HILT penetrates deep tissues to induce photochemical and photothermal effects. It is hypothesized to promote tissue repair by increasing ATP synthesis at the mitochondrial level, regulating Na/K pump activity, and providing analgesia by suppressing inflammatory mediators .

Although HILT is used in clinical practice, there is a scarcity of sham-controlled, double-blind studies that comprehensively evaluate its efficacy using a combination of clinical, electrophysiological, and ultrasonographic (median nerve cross-sectional area) parameters .

Study Objective: The primary objective of this prospective, randomized, double-blind, sham-controlled trial is to provide evidence-based data on the efficacy of HILT regarding pain, hand function, grip strength, nerve conduction velocities, and median nerve morphology (ultrasonographic cross-sectional area) in patients with mild-to-moderate CTS.

Study Population and Design: Patients aged 18-65 years presenting to the Physical Therapy Clinic with clinically and electrophysiologically confirmed 80 patient hand mild-to-moderate CTS will be recruited.

Outcome Measures and Timeline: Assessments will be performed by independent blinded researchers at Baseline, Month 1, and Month 3 post-treatment.

  • Clinical Assessment: Pain intensity (Visual Analog Scale - VAS), symptom severity and functional status (Boston Carpal Tunnel Questionnaire - BCTQ), gross grip strength (Hand Dynamometer), and pinch strength (Pinchmeter) .
  • Ultrasonographic Assessment: Measurement of the median nerve Cross-Sectional Area (CSA) at the proximal carpal tunnel inlet.
  • Electrophysiological Assessment: Sensory and motor nerve conduction studies of the median nerve (evaluating distal latency, conduction velocity, and amplitude).

This study aims to demonstrate the multifaceted contribution (clinical, anatomical, and physiological) of HILT to nerve recovery by reducing edema and inflammation in the pathophysiology of CTS.

연구 유형

중재적

등록 (실제)

80

단계

  • 해당 없음

연락처 및 위치

이 섹션에서는 연구를 수행하는 사람들의 연락처 정보와 이 연구가 수행되는 장소에 대한 정보를 제공합니다.

연구 장소

    • Ankara, Çankaya
      • Ankara, Ankara, Çankaya, 터키 (Türkiye), 06800
        • Ankara Bilkent City Hospital

참여기준

연구원은 적격성 기준이라는 특정 설명에 맞는 사람을 찾습니다. 이러한 기준의 몇 가지 예는 개인의 일반적인 건강 상태 또는 이전 치료입니다.

자격 기준

공부할 수 있는 나이

18년 (성인, 고령자)

건강한 자원 봉사자를 받아들입니다

아니

연구 대상 성별

모두

설명

Inclusion Criteria:

  • Age between 18 and 65 years
  • Clinical symptoms consistent with carpal tunnel syndrome
  • Electrophysiologically confirmed mild or moderate carpal tunnel syndrome
  • Ability to comply with the study protocol and follow-up assessments
  • Provided written informed consent

Exclusion Criteria:

  • Severe carpal tunnel syndrome on electrophysiological examination
  • Previous surgical treatment for carpal tunnel syndrome
  • Local causes of carpal tunnel syndrome (e.g., mass lesions, ganglion cysts, tumors)
  • Systemic conditions associated with carpal tunnel syndrome (e.g., diabetes mellitus, hypothyroidism, pregnancy, acromegaly)
  • History of corticosteroid injection for carpal tunnel syndrome within the last 6 months
  • Presence of polyneuropathy, radiculopathy, or other upper extremity peripheral nerve disorders
  • Contraindications to electrophysiological testing or laser therapy
  • Inability to complete follow-up assessments

공부 계획

이 섹션에서는 연구 설계 방법과 연구가 측정하는 내용을 포함하여 연구 계획에 대한 세부 정보를 제공합니다.

연구는 어떻게 설계됩니까?

디자인 세부사항

  • 주 목적: 치료
  • 할당: 무작위
  • 중재 모델: 병렬 할당
  • 마스킹: 하나의

무기와 개입

참가자 그룹 / 팔
개입 / 치료
실험적: High-Intensity Laser Therapy (HILT)

Patients in this group will receive High-Intensity Laser Therapy (HILT) in addition to using a neutral wrist splint. The treatment will consist of a total of 10 sessions, administered 5 days per week for a duration of 2 weeks.

Procedure: The laser is applied to the carpal tunnel area while the patient's forearm is in supination.

Device Specifications: Pulsed Nd:YAG laser source with Peak Power >3000 W, Intensity (max) 15,000 W/cm², Frequency 10-30 Hz, Pulse duration ≤ 100 μs, and a spot size of 0.5 cm diameter (0.2 cm²).

Treatment Protocol (3 Phases):

  1. Initial Rapid Scan (3 Steps):

    Step 1: 25 Hz, 510 mJ/cm², 139 J energy.

    Step 2: 20 Hz, 610 mJ/cm², 139 J energy.

    Step 3: 19 Hz, 710 mJ/cm², 139 J energy.

  2. Trigger Point Phase: Applied to painful points on the affected side.

    Step 1: 15 Hz, 360 mJ/cm², 6.3 J energy.

    Step 2: 15 Hz, 510 mJ/cm², 9 J energy.

    Step 3: 14 Hz, 610 mJ/cm², 10.1 J energy (applied for 6 seconds per point).

  3. Final Slow Scan: Performed using the same parameters as the rapid scan phase.

Total Energy: A total of 835 Joules is delivered per session.

가짜 비교기: Sham High-Intensity Laser Therapy

Patients in this group will receive sham (placebo) laser therapy in addition to using a neutral wrist splint. The treatment will consist of a total of 10 sessions, administered 5 days per week for a duration of 2 weeks.

The same HIRO TT device is used with the same positioning and duration as the experimental group. The device provides auditory and visual cues identical to the active treatment, but no laser energy is emitted to the tissue. Participants will also use a standard wrist splint.

연구는 무엇을 측정합니까?

주요 결과 측정

결과 측정
측정값 설명
기간
Pain Severity assessed by Visual Analog Scale (VAS)
기간: At baseline (pre-treatment), and at 1 and 3 months following the conclusion of the 2-week treatment period.

Pain intensity will be evaluated using the Visual Analog Scale (VAS). This is a self-reported scale ranging from 0 to 10, where 0 indicates "no pain" and 10 indicates "severe pain". Higher scores indicate a worse outcome (greater pain intensity).

At baseline (pre-treatment), and at 1 and 3 months following the conclusion of the 2-week treatment period.
Symptom Severity and Functional Status assessed by Boston Carpal Tunnel Questionnaire (BCTQ)
기간: At baseline (pre-treatment), and at 1 and 3 months following the conclusion of the 2-week treatment period.

The BCTQ consists of two subscales: the Symptom Severity Scale (SSS) and the Functional Status Scale (FSS). The SSS has 11 items and the FSS has 8 items. Each item is scored on a scale from 1 to 5, where 1 indicates "no symptoms/no difficulty" and 5 indicates "severe symptoms/cannot perform activity". The final score is calculated as the mean of the items. Higher scores indicate a worse outcome (more severe symptoms and greater functional impairment).

At baseline (pre-treatment), and at 1 and 3 months following the conclusion of the 2-week treatment period.

2차 결과 측정

결과 측정
측정값 설명
기간
Median Nerve Cross-Sectional Area(CSA)
기간: At baseline (pre-treatment), and at 1 and 3 months following the conclusion of the 2-week treatment period

The cross-sectional area of the median nerve will be measured by ultrasonography at the proximal carpal tunnel level. In Carpal Tunnel Syndrome (CTS), the nerve typically swells due to edema and inflammation. A decrease in the cross-sectional area indicates a positive response to treatment.

Unit of Measure: Square millimeters (mm²) Interpretation: Lower values indicate a better clinical outcome (reduction in nerve edema).BE

At baseline (pre-treatment), and at 1 and 3 months following the conclusion of the 2-week treatment period
Hand Grip Strength
기간: At baseline (pre-treatment), and at 1 and 3 months following the conclusion of the 2-week treatment period.

Evaluation of the maximum isometric strength of the hand and forearm muscles using a hydraulic hand dynamometer (Baseline® hydraulic LCD hand dynamometer). The measurement is performed with the patient seated, elbow flexed at 90 degrees and wrist in a neutral position. The average of three measurements is recorded.

Interpretation: Higher scores indicate a better outcome. An increase in grip strength suggests improved muscular function and a reduction in the inhibitory effects of pain and nerve compression caused by Carpal Tunnel Syndrome.

Unit of Measure: Kilograms (kg)

At baseline (pre-treatment), and at 1 and 3 months following the conclusion of the 2-week treatment period.
Pinch Strength (Lateral Pinch)
기간: Time Frame: At baseline (pre-treatment), and at 1 and 3 months following the conclusion of the 2-week treatment period.

Description: Evaluation of the strength of the pinch between the thumb and the index finger using a hydraulic pinch gauge (Baseline® hydraulic LCD pinch gauge). Lateral pinch is measured by asking the patient to press between the pad of the thumb and the lateral aspect of the index finger.

Interpretation: Higher scores indicate a better outcome. Improved pinch strength reflects better coordination and strength of the intrinsic hand muscles innervated by the median nerve.

Unit of Measure: Kilograms (kg)

Time Frame: At baseline (pre-treatment), and at 1 and 3 months following the conclusion of the 2-week treatment period.
Median Nerve Motor Distal Latency (MDL)
기간: At baseline (pre-treatment), and at 1 and 3 months following the conclusion of the 2-week treatment period.

Evaluation of the motor component of the median nerve using an Electroneuromyography (ENMG) device (Nihon Kohden Neuropack 2).

MDL reflects the time taken for an electrical impulse to travel from the wrist to the thenar muscle.

Unit of Measure: Milliseconds (ms) Interpretation: Lower scores (shorter latency) indicate a better outcome. A decrease in latency suggests improved nerve conduction across the carpal tunnel, reflecting a reduction in nerve compression.

At baseline (pre-treatment), and at 1 and 3 months following the conclusion of the 2-week treatment period.
Median Nerve Compound Muscle Action Potential (CMAP) Amplitude
기간: At baseline (pre-treatment), and at 1 and 3 months following the conclusion of the 2-week treatment period.

Measurement of the motor action potential amplitude, reflecting the integrity of the motor axons and neuromuscular junctions.

Unit of Measure: Millivolts (mV) Interpretation: Higher amplitudes indicate a better outcome. An increase in amplitude suggests better motor axon recruitment and improved neuromuscular function.

At baseline (pre-treatment), and at 1 and 3 months following the conclusion of the 2-week treatment period.
Median Nerve Sensory Conduction Velocity (Palmar)
기간: At baseline (pre-treatment), and at 1 and 3 months following the conclusion of the 2-week treatment period.

Description: Measurement of the sensory conduction speed of the median nerve in the palmar segment (palm-to-wrist). This segment is often more sensitive to early compression within the carpal tunnel.

Interpretation: Higher scores (faster velocity) indicate a better outcome. An increase in velocity indicates improved nerve function in the specific segment where compression is most prominent.

Unit of Measure: Meters per second (m/s)

At baseline (pre-treatment), and at 1 and 3 months following the conclusion of the 2-week treatment period.
Median Nerve Sensory Conduction Velocity (SCV)(Digit 2)
기간: At baseline (pre-treatment), and at 1 and 3 months following the conclusion of the 2-week treatment period.

Description: Evaluation of the sensory conduction speed of the median nerve recorded from the 2nd digit to the wrist. It measures how fast electrical impulses travel through the distal part of the nerve.

Interpretation: Higher scores (faster velocity) indicate a better outcome. An increase in velocity suggests that the sensory fibers of the median nerve are recovering and conducting signals more efficiently.

Unit of Measure: Meters per second (m/s)

At baseline (pre-treatment), and at 1 and 3 months following the conclusion of the 2-week treatment period.
Median Nerve Sensory Action Potential (SNAP) Amplitude (Palmar)
기간: At baseline (pre-treatment), and at 1 and 3 months following the conclusion of the 2-week treatment period.

Description: Peak-to-peak measurement of the electrical response of the median nerve sensory fibers, recorded from the palmar segment to the wrist.

Interpretation: Higher amplitudes indicate a better outcome. An increase in palmar SNAP amplitude indicates a recovery in the number of sensory fibers successfully conducting through the carpal tunnel.

Unit of Measure: Microvolts (µV)

At baseline (pre-treatment), and at 1 and 3 months following the conclusion of the 2-week treatment period.
Median Nerve Sensory Action Potential (SNAP) Amplitude (Digit 2)
기간: At baseline (pre-treatment), and at 1 and 3 months following the conclusion of the 2-week treatment period.

Description: Peak-to-peak measurement of the electrical response of the median nerve sensory fibers, recorded from the 2nd digit.

Interpretation: Higher amplitudes indicate a better outcome. Increased amplitude reflects a greater number of healthy, functioning sensory axons and improved nerve integrity.

Unit of Measure: Microvolts (µV)

At baseline (pre-treatment), and at 1 and 3 months following the conclusion of the 2-week treatment period.

공동 작업자 및 조사자

여기에서 이 연구와 관련된 사람과 조직을 찾을 수 있습니다.

스폰서

수사관

  • 수석 연구원: Filiz Eser, professor, Ankara City Hospital Bilkent

간행물 및 유용한 링크

연구에 대한 정보 입력을 담당하는 사람이 자발적으로 이러한 간행물을 제공합니다. 이것은 연구와 관련된 모든 것에 관한 것일 수 있습니다.

연구 기록 날짜

이 날짜는 ClinicalTrials.gov에 대한 연구 기록 및 요약 결과 제출의 진행 상황을 추적합니다. 연구 기록 및 보고된 결과는 공개 웹사이트에 게시되기 전에 특정 품질 관리 기준을 충족하는지 확인하기 위해 국립 의학 도서관(NLM)에서 검토합니다.

연구 주요 날짜

연구 시작 (실제)

2025년 11월 2일

기본 완료 (실제)

2026년 2월 13일

연구 완료 (실제)

2026년 4월 30일

연구 등록 날짜

최초 제출

2026년 1월 14일

QC 기준을 충족하는 최초 제출

2026년 2월 12일

처음 게시됨 (실제)

2026년 2월 17일

연구 기록 업데이트

마지막 업데이트 게시됨 (실제)

2026년 11월 12일

QC 기준을 충족하는 마지막 업데이트 제출

2026년 11월 10일

마지막으로 확인됨

2025년 12월 1일

추가 정보

이 연구와 관련된 용어

기타 연구 ID 번호

  • 1-24-647

개별 참가자 데이터(IPD) 계획

개별 참가자 데이터(IPD)를 공유할 계획입니까?

아니요

약물 및 장치 정보, 연구 문서

미국 FDA 규제 의약품 연구

아니

미국 FDA 규제 기기 제품 연구

아니

이 정보는 변경 없이 clinicaltrials.gov 웹사이트에서 직접 가져온 것입니다. 귀하의 연구 세부 정보를 변경, 제거 또는 업데이트하도록 요청하는 경우 register@clinicaltrials.gov. 문의하십시오. 변경 사항이 clinicaltrials.gov에 구현되는 즉시 저희 웹사이트에도 자동으로 업데이트됩니다. .