이 페이지는 자동 번역되었으며 번역의 정확성을 보장하지 않습니다. 참조하십시오 영문판 원본 텍스트의 경우.

패혈성 쇼크에서 체액 반응성 예측을 위한 동적 SvO2

2026년 11월 13일 업데이트: Nevine Mostafa Soliman, Menoufia University

패혈성 쇼크에서 체액 반응성 예측을 위한 동적 중심정맥 산소포화도의 진단적 정확성: 전향적 관찰 연구

This prospective observational diagnostic accuracy study investigates the efficacy of dynamic central venous oxygen saturation in predicting fluid responsiveness in septic shock, compared to measurements obtained using echocardiography (VTI) and cardiometry. We will correlate the changes in measuring cardiac output by both echocardiography and cardiometry with the changes in dynamic central venous oxygen saturation both at baseline and after fluid challenge to investigate the efficacy of dynamic central venous oxygen saturation in predicting fluid responsiveness in septic shock.

연구 개요

상태

모병

정황

개입 / 치료

상세 설명

All patients will undergo standardized monitoring to ensure accurate and reproducible hemodynamic assessment throughout the study period.

Blood pressure will be monitored noninvasively using an automated oscillometric cuff applied to the upper arm. MAP will be maintained at ≥65 mmHg with vasopressor support as required, and no changes in vasopressor infusion will be permitted during the measurement period.

A central venous catheter will be inserted in the internal jugular or subclavian vein, with the position confirmed by chest radiography. Central venous blood samples will be collected at baseline and after the fluid challenge for the determination of a Central venous oxygen saturation (ScvO₂).

Echocardiographic Assessment Left ventricular outflow tract (LVOT) diameter will be measured in the parasternal long-axis view by transthoracic echocardiography (Sonoscape S8 Echocardiography), and Doppler assessment of velocity- time integral (VTI) will be obtained in the apical five-chamber view. Stroke volume (SV) will be calculated as LVOT area × VTI, and values will be averaged from three consecutive cardiac cycles over a single respiratory cycle. The echocardiography operator will be an expert intensivist in echo operation (more than 7 years of experience), and the operator will be blinded to ScvO2.

Cardiac Output Monitoring (Electrical Cardiometry) Cardiac output will also be assessed noninvasively using a validated electrical cardiometry device (ICON®, Osypka Medical, Germany).

Parameters including stroke volume, cardiac output, and cardiac index will be documented at baseline and after the fluid challenge. Device calibration will be verified before each study session.

Timing of Measurements

Hemodynamic variables and oxygenation parameters will be recorded at two prespecified time points:

  1. Baseline - immediately prior to fluid challenge or passive leg raising maneuver.
  2. Post-intervention - within 5 minutes following intervention. Intervention A standardized fluid challenge protocol will be employed. Indications for fluid administration will include: Hypotension, defined as systolic blood pressure (SBP) ≤ 90 mmHg, a reduction in SBP ≥ 40 mmHg in patients with pre-existing hypertension, or mean arterial pressure (MAP) ≤ 65 mmHg, or evidence of tissue hypoperfusion, such as delayed capillary refill time, skin mottling, altered mental status, urine output ≤ 0.5 mL/kg/h for > 2 hours, or hyperlactatemia (> 2 mmol/L).

Eligible patients will receive a rapid infusion of 500 mL isotonic crystalloid solution ( normal saline) administered over a 15-minute period.

Throughout the intervention, all concomitant therapies-including background maintenance fluids, vasopressor or inotrope dosage, and mechanical ventilation settings-will remain unchanged to avoid confounding effects on hemodynamic measurements.

Definition of Fluid Responsiveness Fluid responsiveness will be defined as an increase in stroke volume index (derived from echocardiography or cardiometry) of ≥10- 15% after the intervention. This definition is consistent with established hemodynamic criteria and will serve as the reference standard for comparison with dynamic changes in ScvO₂. Stroke Volume Index (SVI) is the volume of blood pumped by the heart's ventricle with each beat, normalized to the individual's body surface area (BSA).

Data Collection For each patient, the following variables were systematically recorded: Baseline characteristics

  • Demographic data (age, sex), and Comorbidities

  • Source of infection

  • Severity of illness scores:

    o Acute Physiology and Chronic Health Evaluation II (APACHE II) o Sequential Organ Failure Assessment (SOFA)

  • Life-support therapies as vasopressor use.

  • Clinical outcomes (ICU length of stay, mortality) Hemodynamic and laboratory parameters Measured at two time points: immediately before the fluid challenge and within five minutes after completion.

  • Heart rate (beats/min)

  • Blood pressure

  • Hemoglobin concentration (Hb, g/dL)

  • Cardiac output (CO) by echocsardiography and electrical cardiometry

  • Central venous blood gas analysis: Central venous oxygen saturation (ScvO₂)

연구 유형

관찰

등록 (추정된)

115

연락처 및 위치

이 섹션에서는 연구를 수행하는 사람들의 연락처 정보와 이 연구가 수행되는 장소에 대한 정보를 제공합니다.

연구 장소

참여기준

연구원은 적격성 기준이라는 특정 설명에 맞는 사람을 찾습니다. 이러한 기준의 몇 가지 예는 개인의 일반적인 건강 상태 또는 이전 치료입니다.

자격 기준

공부할 수 있는 나이

18년 이상 (성인, 고령자)

건강한 자원 봉사자를 받아들입니다

아니

연구 대상 성별

모두

샘플링 방법

확률 샘플

연구 인구

This single-center, prospective, observational study will be conducted in the Intensive Care Unit (ICU) at Menoufia University Hospitals. Adults spontaneously breathing patients with septic shock who undergo a fluid challenge as a part of their hemodynamic management in the first 24 hours will be eligible for enrollment. Ethical approval will be obtained from the ethics committee at the Menoufia Faculty of Medicine, and the study will follow ethical guidelines and secure approval from the Institutional Review Board (IRB). Written informed consent will be obtained from each participant or their legal surrogate before study inclusion.

설명

Inclusion Criteria:

  • Age > 18 years
  • Diagnosis of septic shock according to Sepsis-3 criteria:

Suspected or confirmed infection o Requirement for vasopressors to maintain MAP > 65 mmHg o Serum lactate > 2 mmol/L despite adequate fluid resuscitation

Exclusion Criteria:

  • Pregnancy
  • Significant valvular heart disease.
  • Atrial fibrillation.
  • Inadequate echocardiographic window.
  • Ongoing bleeding or contraindication to fluid bolus.

공부 계획

이 섹션에서는 연구 설계 방법과 연구가 측정하는 내용을 포함하여 연구 계획에 대한 세부 정보를 제공합니다.

연구는 어떻게 설계됩니까?

디자인 세부사항

  • 관찰 모델: COHORT
  • 시간 관점: PROSPECTIVE

연구는 무엇을 측정합니까?

주요 결과 측정

결과 측정
기간
기준선에서와 체액 도전 후 동적 중심정맥 산소 포화도(ScvO2) 측정
기간: 30분 후
30분 후

2차 결과 측정

결과 측정
측정값 설명
기간
Measuring Cardiac output by echocardiography or cardiometry at baseline and after fluid challenge.
기간: After 30 mins

We will correlate the changes in measuring cardiac output by both echocardiography and cardiometry with the changes in dynamic central venous oxygen saturation both at baseline and after fluid challenge to investigate the efficacy of dynamic central venous oxygen saturation in predicting fluid responsiveness in septic shock.

After 30 mins

공동 작업자 및 조사자

여기에서 이 연구와 관련된 사람과 조직을 찾을 수 있습니다.

스폰서

연구 기록 날짜

이 날짜는 ClinicalTrials.gov에 대한 연구 기록 및 요약 결과 제출의 진행 상황을 추적합니다. 연구 기록 및 보고된 결과는 공개 웹사이트에 게시되기 전에 특정 품질 관리 기준을 충족하는지 확인하기 위해 국립 의학 도서관(NLM)에서 검토합니다.

연구 주요 날짜

연구 시작 (추정된)

2026년 11월 1일

기본 완료 (추정된)

2027년 1월 1일

연구 완료 (추정된)

2027년 2월 1일

연구 등록 날짜

최초 제출

2026년 3월 29일

QC 기준을 충족하는 최초 제출

2026년 4월 2일

처음 게시됨 (실제)

2026년 4월 7일

연구 기록 업데이트

마지막 업데이트 게시됨 (실제)

2026년 11월 16일

QC 기준을 충족하는 마지막 업데이트 제출

2026년 11월 13일

마지막으로 확인됨

2026년 1월 1일

추가 정보

이 연구와 관련된 용어

기타 연구 ID 번호

  • 1/2026ANET30

개별 참가자 데이터(IPD) 계획

개별 참가자 데이터(IPD)를 공유할 계획입니까?

아니요

약물 및 장치 정보, 연구 문서

미국 FDA 규제 의약품 연구

아니

미국 FDA 규제 기기 제품 연구

아니

이 정보는 변경 없이 clinicaltrials.gov 웹사이트에서 직접 가져온 것입니다. 귀하의 연구 세부 정보를 변경, 제거 또는 업데이트하도록 요청하는 경우 register@clinicaltrials.gov. 문의하십시오. 변경 사항이 clinicaltrials.gov에 구현되는 즉시 저희 웹사이트에도 자동으로 업데이트됩니다. .