VO2max and Substrate Crossover Point (VO2MAX-CROSS)
Higher VO2max Delays Substrate Switching and Shifts the Crossover Point to Greater Oxygen Uptake During Incremental Exerciseebys
연구 개요
상태
상태
정황
정황
개입 / 치료
개입 / 치료
상세 설명
This study evaluates the relationship between maximal oxygen uptake (VO2max) and the substrate crossover point during incremental treadmill exercise in young, physically active individuals. Substrate utilization kinetics and metabolic flexibility represent critical components of cardiovascular conditioning and endurance performance; however, the impact of continuous variations in aerobic capacity on the onset of metabolic transition requires detailed investigation.
Participants undergo anthropometric testing followed by a maximal graded exercise test on a motor-driven treadmill following the standard Bruce protocol. Breath-by-breath expired gas analysis using indirect calorimetry continuously monitors oxygen uptake (VO2), carbon dioxide production (VCO2), and minute ventilation (VE) throughout the test. Respiratory exchange ratio (RER) values are calculated continuously. The substrate crossover point is operationally defined as the exercise intensity corresponding to an RER threshold of 0.85, representing the metabolic transition where carbohydrate oxidation becomes the predominant contributor to total energy expenditure over lipid oxidation.
Key outcome measures extracted at this threshold include:
Time to reach the crossover point (minutes)
Absolute oxygen uptake at crossover (liters per minute [L/min])
Relative oxygen uptake at crossover (milliliters per kilogram per minute [mL/kg/min])
Percentage of maximal oxygen uptake at crossover (%VO2max)
Heart rate at crossover (beats per minute [bpm])
Statistical associations between maximal aerobic capacity (VO2max) and the primary outcome measures at the crossover point are analyzed using linear correlation and regression models to determine how cardiorespiratory fitness alters substrate switching kinetics under progressive physical strain.
연구 유형
연구 유형
등록 (실제)
등록
단계
단계
- 해당 없음
연락처 및 위치
연구 장소
-
-
Tepebaşi
-
Eskişehir, Tepebaşi, 터키 (Türkiye), 26100
- Eskişehir Technical University
-
-
참여기준
자격 기준
자격 기준
공부할 수 있는 나이
- 성인
건강한 자원 봉사자를 받아들입니다
설명
Inclusion Criteria:
- Healthy male or female physical education students aged 18 to 30 years
- Regularly physically active (participating in structured physical activity at least 3 days per week)
- Medically cleared and capable of performing maximal graded treadmill exercise testing to voluntary exhaustion
- Willing and able to provide written informed consent
Exclusion Criteria:
- History of cardiovascular, pulmonary, metabolic, renal, or neuromuscular disorders
- Acute musculoskeletal injury or orthopedic condition that impairs treadmill running or maximal exertion
- Current use of prescription medications, stimulants, or dietary supplements known to alter metabolic rate, heart rate, or substrate oxidation
- Use of tobacco, nicotine products, or alcohol within 24 hours prior to testing
- Consumption of caffeine or vigorous physical exercise within 24 hours prior to the exercise trial
공부 계획
연구는 어떻게 설계됩니까?
디자인 세부사항
- 주 목적: 기초 과학
- 할당: 해당 없음
- 중재 모델: 단일 그룹 할당
- 마스킹: 없음(오픈 라벨)
팔의 수
무기와 개입
참가자 그룹 / 팔참가자 그룹 / 팔 |
개입 / 치료개입 / 치료 |
|---|---|
|
실험적: Exercise Testing Group
: Healthy young adult participants who undergo a single maximal incremental treadmill exercise test using the Bruce Protocol to assess cardiorespiratory fitness (VO2max) and substrate crossover kinetics.
|
Participants perform a maximal treadmill exercise test following the standardized Bruce Protocol.
The test begins with a warm-up, followed by progressive 3-minute stages with continuous increases in speed and incline until voluntary exhaustion.
Indirect calorimetry is used continuously via breath-by-breath gas analysis to measure VO2VCO2, and RER for substrate crossover determination.
다른 이름들:
|
연구는 무엇을 측정합니까?
주요 결과 측정
주요 결과 측정
결과 측정 |
측정값 설명 |
기간 |
|---|---|---|
|
Time to reach the substrate crossover point
기간: Time Frame: Baseline (single test session, Day 1)
|
Measure Description: Elapsed time (in minutes) from the start of the incremental treadmill test (Bruce protocol) to the point where the respiratory exchange ratio (RER) reaches 0.85, indicating the metabolic crossover where carbohydrate oxidation becomes the predominant fuel source. Time Frame: Baseline (single exercise test session, Day 1) Unit of Measure: Minutes |
Time Frame: Baseline (single test session, Day 1)
|
|
Relative oxygen uptake at the crossover point
기간: Measure Description: Measured continuously during the incremental exercise test using indirect calorimetry, recorded specifically at the point where the respiratory exchange ratio (RER) reaches 0.85. Time Frame: Baseline
|
Measure Title: Relative oxygen uptake at the substrate crossover point Measure Description: Oxygen uptake (VO2) normalized to body weight (mL/kg/min) recorded at the moment the substrate crossover point (respiratory exchange ratio [RER] = 0.85) is reached during the maximal incremental treadmill test (Bruce protocol). Time Frame: Baseline |
Measure Description: Measured continuously during the incremental exercise test using indirect calorimetry, recorded specifically at the point where the respiratory exchange ratio (RER) reaches 0.85. Time Frame: Baseline
|
2차 결과 측정
2차 결과 측정
결과 측정 |
측정값 설명 |
기간 |
|---|---|---|
|
Percentage of VO2max at the crossover point
기간: Measure Description: Relative oxygen uptake (VO2) at the substrate crossover point (respiratory exchange ratio [RER] = 0.85) expressed as a % of the participant's maximal oxygen uptake (VO2max), calculated upon completion of the Bruce protocol
|
Measure Title: Percentage of maximal oxygen uptake at the substrate crossover point Measure Description: Relative oxygen uptake (VO2) at the substrate crossover point (respiratory exchange ratio [RER] = 0.85) expressed as a percentage (%) of the participant's maximal oxygen uptake (VO2max) during the Bruce protocol treadmill test. Time Frame: Baseline |
Measure Description: Relative oxygen uptake (VO2) at the substrate crossover point (respiratory exchange ratio [RER] = 0.85) expressed as a % of the participant's maximal oxygen uptake (VO2max), calculated upon completion of the Bruce protocol
|
|
Heart rate at the crossover point
기간: Measure Description: Heart rate (HR) in beats per minute (bpm) measured continuously during the incremental treadmill test (Bruce protocol), recorded at the substrate crossover threshold (respiratory exchange ratio [RER] = 0.85). Time Frame: Baseline
|
Measure Title: Heart rate at the substrate crossover point Measure Description: Heart rate (HR) recorded in beats per minute (bpm) using a telemetric heart rate monitor at the point where the substrate crossover threshold (respiratory exchange ratio [RER] = 0.85) is achieved during the maximal incremental treadmill test (Bruce protocol). Time Frame: Baseline |
Measure Description: Heart rate (HR) in beats per minute (bpm) measured continuously during the incremental treadmill test (Bruce protocol), recorded at the substrate crossover threshold (respiratory exchange ratio [RER] = 0.85). Time Frame: Baseline
|
|
Maximal oxygen consumption (VO2max)
기간: Measure Description: Relative maximal oxygen uptake (VO2max in mL/kg/min) assessed at maximal exertion at the end of the Bruce protocol treadmill test to voluntary exhaustion via indirect calorimetry. Time Frame: Baseline
|
Measure Description: The highest rate of relative oxygen uptake (VO2 in mL/kg/min) attained during the maximal graded exercise test (Bruce protocol) to voluntary exhaustion via indirect calorimetry. Time Frame: Baseline |
Measure Description: Relative maximal oxygen uptake (VO2max in mL/kg/min) assessed at maximal exertion at the end of the Bruce protocol treadmill test to voluntary exhaustion via indirect calorimetry. Time Frame: Baseline
|
공동 작업자 및 조사자
수사관
수사관
- 수석 연구원: celil kaçoğlu, Ph.D., Eskişehir Teknik Üniversitesi
간행물 및 유용한 링크
연구 기록 날짜
연구 주요 날짜
연구 시작 (실제)
연구 시작
기본 완료 (실제)
기본 완료
연구 완료 (실제)
연구 완료
연구 등록 날짜
최초 제출
최초 제출
QC 기준을 충족하는 최초 제출
QC 기준을 충족하는 최초 제출
처음 게시됨 (실제)
처음 게시됨
연구 기록 업데이트
마지막 업데이트 게시됨 (실제)
마지막 업데이트 게시됨
QC 기준을 충족하는 마지막 업데이트 제출
QC 기준을 충족하는 마지막 업데이트 제출
마지막으로 확인됨
마지막으로 확인됨
추가 정보
이 연구와 관련된 용어
키워드
기타 연구 ID 번호
기타 연구 ID 번호
- EskisehirTU-SBF-CK-04
개별 참가자 데이터(IPD) 계획
개별 참가자 데이터(IPD)를 공유할 계획입니까?
IPD 계획 설명
약물 및 장치 정보, 연구 문서
미국 FDA 규제 의약품 연구
미국 FDA 규제 기기 제품 연구
이 정보는 변경 없이 clinicaltrials.gov 웹사이트에서 직접 가져온 것입니다. 귀하의 연구 세부 정보를 변경, 제거 또는 업데이트하도록 요청하는 경우 register@clinicaltrials.gov. 문의하십시오. 변경 사항이 clinicaltrials.gov에 구현되는 즉시 저희 웹사이트에도 자동으로 업데이트됩니다. .