Artificial Intelligence for Staging Glaucoma Severity: A Comparison With an Eye Specialist Using Visual Field Tests (AI-GSS2)
Reliability of Artificial Intelligence in Glaucoma Severity Staging Using the Brusini GSS2 System: A Longitudinal Comparative Study Against Expert Assessment
The study titled "Reliability of Artificial Intelligence in Glaucoma Severity Staging Using the Brusini GSS2 System: A Longitudinal Comparative Study against Expert Assessment" aims to evaluate the diagnostic reliability and clinical utility of an Artificial Intelligence (AI) system in staging glaucoma severity using the Brusini Glaucoma Staging System 2 (GSS2) compared to expert ophthalmologist assessment.
The study protocol involves the longitudinal analysis of visual fields (VFs) collected at baseline (T0) and at a 1-year follow-up (T1). Statistical methodology will utilize quadratic weighted Cohen's kappa to assess diagnostic agreement between the AI system and expert assessment, Wilcoxon signed-rank tests to evaluate potential systematic bias, and Spearman's rank correlation to investigate the relationship between longitudinal progression and changes in the clinical Visual Field Index.
연구 개요
상태
상태
정황
정황
개입 / 치료
개입 / 치료
연구 유형
연구 유형
등록 (실제)
등록
연락처 및 위치
연구 장소
-
-
-
Salerno, 이탈리아, 84084
- University of Salerno
-
-
참여기준
자격 기준
자격 기준
공부할 수 있는 나이
- 어린이
- 성인
- 고령자
건강한 자원 봉사자를 받아들입니다
샘플링 방법
연구 인구
설명
Inclusion Criteria:
- Adults (≥18 years of age).
- Diagnosis of glaucoma or suspected glaucoma undergoing routine clinical follow-up.
- Availability of reliable standard automated visual field (VF) examinations at baseline and approximately 1-year follow-up.
- Visual field tests suitable for staging using the Brusini Glaucoma Staging System 2 (GSS2).
- Availability of all clinical data required for study analysis.
Exclusion Criteria:
- Unreliable visual field examinations (e.g., excessive fixation losses, false-positive or false-negative responses according to institutional reliability criteria).
- Visual field defects attributable to ocular or neurological diseases other than glaucoma.
- Missing baseline or follow-up visual field examinations.
- Incomplete clinical data preventing GSS2 staging or statistical analysis.
- Previous ocular conditions or interventions that could significantly affect visual field interpretation, if judged by the investigator.
공부 계획
연구는 어떻게 설계됩니까?
디자인 세부사항
그룹/코호트 수
코호트 및 개입
그룹/코호트그룹/코호트 |
개입 / 치료개입 / 치료 |
|---|---|
|
Glaucoma Patients
|
An artificial intelligence system used to automatically stage glaucoma severity from standard automated visual field tests according to the Brusini Glaucoma Staging System 2 (GSS2).
AI classifications were compared with those of an expert ophthalmologist at baseline and 1-year follow-up.
The AI was used for assessment only and did not influence patient management or treatment.
|
연구는 무엇을 측정합니까?
주요 결과 측정
주요 결과 측정
결과 측정 |
측정값 설명 |
기간 |
|---|---|---|
|
Quadratic weighted Cohen's kappa coefficient for diagnostic agreement in glaucoma severity staging between AI and expert assessment
기간: Baseline (T0) and 1-year follow-up (T1)
|
Glaucoma severity will be staged (from Stage 0 to Stage 5) using the Brusini Glaucoma Staging System 2 (GSS2) based on visual field parameters.
Staging will be performed independently by the AI system and an expert ophthalmologist at each time point.
Inter-rater agreement between the AI and expert staging will be quantified using the quadratic weighted Cohen's kappa ($\kappa$), where values range from -1 (complete disagreement) to +1 (perfect agreement).
|
Baseline (T0) and 1-year follow-up (T1)
|
2차 결과 측정
2차 결과 측정
결과 측정 |
측정값 설명 |
기간 |
|---|---|---|
|
Median difference in Brusini GSS2 staging scores between AI and expert assessment
기간: Baseline (T0) and 1-year follow-up (T1)
|
Differences in Brusini Glaucoma Staging System 2 (GSS2) staging scores (ranging from Stage 0 to Stage 5) assigned by the AI system versus the expert ophthalmologist will be evaluated to detect systematic overestimation or underestimation of disease severity.
Paired score differences (AI minus Expert) at each time point will be reported and statistically tested using the Wilcoxon signed-rank test.
|
Baseline (T0) and 1-year follow-up (T1)
|
공동 작업자 및 조사자
연구 기록 날짜
연구 주요 날짜
연구 시작 (실제)
연구 시작
기본 완료 (실제)
기본 완료
연구 완료 (실제)
연구 완료
연구 등록 날짜
최초 제출
최초 제출
QC 기준을 충족하는 최초 제출
QC 기준을 충족하는 최초 제출
처음 게시됨 (실제)
처음 게시됨
연구 기록 업데이트
마지막 업데이트 게시됨 (실제)
마지막 업데이트 게시됨
QC 기준을 충족하는 마지막 업데이트 제출
QC 기준을 충족하는 마지막 업데이트 제출
마지막으로 확인됨
마지막으로 확인됨
추가 정보
이 연구와 관련된 용어
기타 연구 ID 번호
기타 연구 ID 번호
- OftalmoUnisa2026_1
개별 참가자 데이터(IPD) 계획
개별 참가자 데이터(IPD)를 공유할 계획입니까?
약물 및 장치 정보, 연구 문서
미국 FDA 규제 의약품 연구
미국 FDA 규제 기기 제품 연구