Capsular Tension Ring With Hydrophilic Versus Hydrophobic Intraocular Lenses (CTR-IOL-3ARM)

2026년 9월 21일 업데이트: Ehab Mohamed Elsayed Mohamed Saad, Benha University

Outcomes of Hydrophilic Intraocular Lens Implantation With and Without a Capsular Tension Ring Versus Hydrophobic Intraocular Lens Implantation Alone: A Randomized Controlled Trial

This study compares three approaches to cataract surgery. Cataract surgery involves removing the eye's cloudy natural lens and replacing it with an artificial intraocular lens (IOL) to restore clear vision. IOLs are made from different materials, most commonly a "hydrophilic" (water-attracting) acrylic or a "hydrophobic" (water-repelling) acrylic. Hydrophilic lenses are generally easier and less expensive to use, but have been linked in past research to a higher chance of the lens capsule becoming cloudy again after surgery (posterior capsule opacification, or PCO), sometimes requiring a follow-up laser treatment. Hydrophobic lenses tend to have lower rates of this problem but can cost more.

A capsular tension ring (CTR) is a small flexible ring that can be placed inside the eye at the time of surgery to help hold the lens capsule in a stable, round shape. This study asks whether adding a CTR when a hydrophilic lens is used can reduce the disadvantages usually seen with that lens material.

600 adult patients (ages 50-80) undergoing cataract surgery at three hospitals in Egypt were randomly assigned to one of three groups: (1) a hydrophilic lens plus a CTR, (2) a hydrophobic lens alone (the common comparison approach), or (3) a hydrophilic lens alone without a CTR. Patients were followed for 24 months, and researchers compared vision, glasses prescription accuracy, lens position, capsule clouding, need for laser treatment, and surgical complications between the groups.

The results showed that adding a CTR to a hydrophilic lens produced results very similar to using a hydrophobic lens alone. In contrast, using a hydrophilic lens without a CTR resulted in worse vision, less accurate glasses prescriptions, more lens shifting or tilting, more capsule clouding, a higher need for laser treatment, and more complications compared with the hydrophobic lens. These findings suggest that adding a CTR may be a simple, low-cost way to improve outcomes when a hydrophilic lens is used for cataract surgery.

연구 개요

상태

완전한

정황

개입 / 치료

상세 설명

Background and rationale: Phacoemulsification with intraocular lens (IOL) implantation is the standard treatment for age-related cataract. IOL material (hydrophilic versus hydrophobic acrylic) is a recognized determinant of long-term capsular biocompatibility, with hydrophobic acrylic lenses generally associated with lower rates of posterior capsule opacification (PCO) and reduced need for neodymium-doped yttrium aluminum garnet (Nd:YAG) laser capsulotomy compared with hydrophilic acrylic lenses. Capsular tension rings (CTRs) are polymethyl methacrylate devices that stabilize the capsular bag equator and have been proposed to mitigate capsular contraction, lens decentration, and PCO, independent of IOL material. Prior comparative work has generally examined either IOL material effects or CTR effects in isolation, or has compared a composite intervention (hydrophilic IOL plus CTR) against a hydrophobic IOL alone, without a design capable of isolating the CTR's independent contribution.

Objectives: To compare visual, refractive, anatomical (IOL position and posterior capsule opacification), and safety outcomes among three approaches to routine cataract surgery: (1) hydrophilic acrylic IOL implantation combined with a CTR (Group A); (2) hydrophobic acrylic IOL implantation alone (Group B); and (3) hydrophilic acrylic IOL implantation alone, without a CTR (Group C). The inclusion of Group C, using the same hydrophilic IOL model as Group A but without CTR insertion, was designed specifically to allow assessment of the CTR's independent contribution when compared against Group A, in addition to the material-based comparisons of Groups A and C against Group B.

Design: Prospective, randomized, parallel-group, three-arm controlled trial conducted at three tertiary ophthalmology centers in Egypt (Zagazig University Hospital, Benha University Hospital, and Al-Azhar University Hospital). Eligible adults aged 50-80 years with visually significant age-related cataract (LOCS III grade >=3) were randomized 1:1:1 using a computer-generated allocation sequence, with allocation concealment via sealed opaque envelopes opened intraoperatively. Outcome assessors and data analysts were blinded to treatment allocation; operating surgeons were not blinded due to the nature of the intervention.

Interventions: All participants underwent standardized phacoemulsification via a 2.2 mm clear corneal incision with a ~5.5 mm continuous curvilinear capsulorhexis. Group A received a hydrophilic acrylic IOL (Eyecryl, Biotech Healthcare, India) plus a polymethyl methacrylate CTR (Auroring CTR 11, Aurolab, India). Group B received a hydrophobic acrylic IOL (AcrySof IQ, Alcon Laboratories, USA) without a CTR. Group C received the same hydrophilic acrylic IOL as Group A, without CTR insertion.

Outcomes: Primary outcomes were best-corrected visual acuity (logMAR) and manifest spherical equivalent refractive error at 24 months, with longitudinal assessment at 1, 3, 6, 12, 18, and 24 months. Secondary outcomes included posterior capsule opacification grade (slit-lamp retroillumination, graded per Aslam et al.), Nd:YAG capsulotomy rate, IOL centration and tilt (anterior segment optical coherence tomography), and intraoperative and postoperative complications (posterior capsule rupture, zonular dialysis, vitreous loss, iris trauma, cystoid macular edema, intraocular pressure elevation, corneal edema, and endophthalmitis).

Follow-up: Scheduled visits at day 1, week 1, and months 1, 3, 6, 12, 18, and 24 postoperatively, with the 24-month visit representing the final prespecified assessment.

Statistical analysis: Continuous variables were compared across groups using one-way ANOVA or Kruskal-Wallis testing as appropriate, with post-hoc pairwise comparisons for Group A vs. Group B and Group C vs. Group B. Categorical variables were compared using chi-square or Fisher's exact test. Repeated-measures ANOVA assessed longitudinal group x time interactions for visual and refractive outcomes.

연구 유형

중재적

등록 (실제)

600

단계

  • 해당 없음

연락처 및 위치

이 섹션에서는 연구를 수행하는 사람들의 연락처 정보와 이 연구가 수행되는 장소에 대한 정보를 제공합니다.

연구 장소

    • Benha
      • Banhā, Benha, 이집트, 13111
        • Benha University

참여기준

연구원은 적격성 기준이라는 특정 설명에 맞는 사람을 찾습니다. 이러한 기준의 몇 가지 예는 개인의 일반적인 건강 상태 또는 이전 치료입니다.

자격 기준

공부할 수 있는 나이

18년 이상 (성인, 고령자)

건강한 자원 봉사자를 받아들입니다

아니

연구 대상 성별

모두

설명

Inclusion Criteria:

  • Age 50-80 years
  • Visually significant age-related cataract, defined as nuclear opacity grade >=3 according to the Lens Opacities Classification System III (LOCS III), graded preoperatively under standardized mydriasis via slit-lamp biomicroscopy
  • Clear cornea
  • Adequate pupillary dilation
  • Anatomically normal capsular bag with no evidence of zonular weakness
  • No ocular comorbidities expected to affect visual or refractive outcomes

Exclusion Criteria:

  • Previous intraocular surgery
  • Ocular trauma
  • Pseudoexfoliation syndrome
  • Posterior polar cataract
  • Zonular instability
  • Complicated cataract
  • Active intraocular inflammation
  • Retinal or optic nerve pathology
  • Anticipated need for additional capsular support devices beyond the study protocol

공부 계획

이 섹션에서는 연구 설계 방법과 연구가 측정하는 내용을 포함하여 연구 계획에 대한 세부 정보를 제공합니다.

연구는 어떻게 설계됩니까?

디자인 세부사항

  • 주 목적: 치료
  • 할당: 무작위
  • 중재 모델: 병렬 할당
  • 마스킹: 하나의

무기와 개입

참가자 그룹 / 팔
개입 / 치료
실험적: U.S. flag An official website of the United States government Here's how you know Skip to main page

Phacoemulsification with implantation of a hydrophilic acrylic intraocular lens (Eyecryl, Biotech Healthcare, India) combined with insertion of a polymethyl methacrylate capsular tension ring (Auroring CTR 11, Aurolab, India).

Foldable hydrophilic acrylic intraocular lens implanted in the capsular bag following phacoemulsification.

Polymethyl methacrylate capsular tension ring (overall diameter 13.0 mm, compressed diameter 11.0 mm) inserted into the capsular bag to distribute equatorial zonular forces and maintain capsular bag contour.

활성 비교기: Group B: Hydrophobic IOL alone

Phacoemulsification with implantation of a hydrophobic acrylic intraocular lens (AcrySof IQ, Alcon Laboratories, USA), without a capsular tension ring.

Foldable hydrophobic acrylic intraocular lens implanted in the capsular bag following phacoemulsification.

실험적: Group C: Hydrophilic IOL alone

Phacoemulsification with implantation of the same hydrophilic acrylic intraocular lens used in Group A (Eyecryl, Biotech Healthcare, India), without capsular tension ring insertion.

Foldable hydrophilic acrylic intraocular lens implanted in the capsular bag following phacoemulsification.

연구는 무엇을 측정합니까?

주요 결과 측정

결과 측정
측정값 설명
기간
Best-corrected visual acuity (BCVA)
기간: 24 months postoperatively

Best-corrected visual acuity measured in logMAR units, assessed longitudinally at 1, 3, 6, 12, 18, and 24 months, with between-group comparison at 24 months as the primary efficacy endpoint.

24 months postoperatively

2차 결과 측정

결과 측정
측정값 설명
기간
Manifest spherical equivalent refractive error
기간: 24 months postoperatively

Manifest spherical equivalent refractive error (diopters), assessed longitudinally at 1, 3, 6, 12, 18, and 24 months, with between-group comparison at 24 months as the primary efficacy endpoint. Proportion of eyes within +/-0.5 D and +/-1.0 D of target refraction was also assessed at 24 months.

24 months postoperatively

공동 작업자 및 조사자

여기에서 이 연구와 관련된 사람과 조직을 찾을 수 있습니다.

스폰서

연구 기록 날짜

이 날짜는 ClinicalTrials.gov에 대한 연구 기록 및 요약 결과 제출의 진행 상황을 추적합니다. 연구 기록 및 보고된 결과는 공개 웹사이트에 게시되기 전에 특정 품질 관리 기준을 충족하는지 확인하기 위해 국립 의학 도서관(NLM)에서 검토합니다.

연구 주요 날짜

연구 시작 (실제)

2022년 12월 15일

기본 완료 (실제)

2026년 5월 15일

연구 완료 (실제)

2026년 5월 15일

연구 등록 날짜

최초 제출

2026년 9월 21일

QC 기준을 충족하는 최초 제출

2026년 9월 21일

처음 게시됨 (실제)

2026년 9월 25일

연구 기록 업데이트

마지막 업데이트 게시됨 (실제)

2026년 9월 25일

QC 기준을 충족하는 마지막 업데이트 제출

2026년 9월 21일

마지막으로 확인됨

2026년 9월 1일

추가 정보

이 연구와 관련된 용어

기타 연구 ID 번호

  • ZU-BU-AU-CTR-IOL-3ARM-2023

약물 및 장치 정보, 연구 문서

미국 FDA 규제 의약품 연구

아니

미국 FDA 규제 기기 제품 연구

아니

이 정보는 변경 없이 clinicaltrials.gov 웹사이트에서 직접 가져온 것입니다. 귀하의 연구 세부 정보를 변경, 제거 또는 업데이트하도록 요청하는 경우 register@clinicaltrials.gov. 문의하십시오. 변경 사항이 clinicaltrials.gov에 구현되는 즉시 저희 웹사이트에도 자동으로 업데이트됩니다. .