Assessment of Binocular Vision Function With Neos™ (ROCKET) (ROCKET)

2026년 10월 30일 업데이트: machineMD AG

Clinical Performance of Neos™ for the Assessment of Binocular Vision Function: A Prospective Multicentre Cross-Sectional Study (ROCKET)

ROCKET evaluates the clinical performance of an investigational version of neos™, a non-invasive device that uses a virtual-reality headset and eye tracking to assess binocular vision-how the two eyes work together.

The study compares neos™ results with standard clinical examinations for three functions: sensory fusion, the ability to combine images from both eyes into a single image; stereopsis, the perception of depth from differences between the images seen by each eye; and suppression, reduced awareness of visual input from one eye during binocular viewing.

Approximately 184 patients aged 3 years and older who require a clinical binocular vision assessment will participate at ophthalmology centres in Switzerland. Each participant will undergo standard clinical testing and a neos™ examination during a single study visit. During the neos™ examination, visual stimuli are presented through the headset while the device records eye movements and pupil responses.

The main objective is to determine how accurately neos™ identifies the presence or absence of sensory fusion, stereopsis and central suppression compared with the clinical reference assessments. Additional analyses will compare fusion-related measurements, characterize stereopsis and suppression, and explore relationships between neos™ measurements and clinical findings.

연구 개요

상태

아직 모집하지 않음

정황

개입 / 치료

상세 설명

The investigation uses a prospective, multicentre, cross-sectional, paired within-participant design. Each participant receives both assessments on the same day and serves as their own comparator, reducing the influence of differences between participants. There is no random allocation. Although the investigation is not formally blinded, clinicians performing the reference examination do not have access to automated neos™ results when determining the clinical classifications. Investigational results do not influence treatment decisions.

The investigation comprises two sequential phases. An initial tuning phase includes 10 selectively recruited participants: five with preserved fusion and stereopsis without suppression, and five with absent fusion and stereopsis and suppression present. These data are used to refine algorithm parameters and thresholds. The algorithm configuration is then locked and remains unchanged throughout the validation phase. Tuning-phase participants are excluded from all analysis sets.

During validation, eligible patients are recruited consecutively when study personnel and procedures are available. Recruitment includes patients with and without suspected or confirmed binocular dysfunction, reflecting the population undergoing clinical binocularity assessment. Approximately 174 participants are expected to enter validation to obtain around 157 evaluable participants. The final enrolment depends on the observed distribution of clinical reference classifications and the proportion of evaluable examinations.

The investigational configuration uses neos™ software version 4.0.0-rocket, incorporating additional binocular visual stimuli and algorithms. The examination typically takes less than 15 minutes. It includes gaze holding and ocular alignment, stimuli for assessing suppression, fusion and stereopsis, pupillary function, saccades, smooth pursuit and visual-field assessment.

The clinical reference examination is performed by an appropriately trained healthcare professional using established methods selected according to clinical findings and participant cooperation. These may include prism bar testing, Bagolini striated lenses, Worth 4-Dot testing and standardized stereotests. Not every test is required for every participant; suitable reference information must be obtained for each primary classification. When specified test results are unavailable, unusable or omitted for clinical reasons, the protocol allows the orthoptist's clinical diagnosis to determine the reference classification.

Prespecified rules define the reference outcomes. Sensory fusion is present when binocular single perception is demonstrated using Bagolini striated lenses or Worth 4-Dot testing. Stereopsis is present when stereoscopic disparity of 600 arcseconds or finer is detected. Central suppression is classified using a hierarchical rule: it is absent when stereopsis or sensory fusion is present. When both are absent, suppression is present if clinical testing demonstrates failure to perceive input from one eye; otherwise, it is classified as absent.

Diagnostic performance is assessed separately for each primary endpoint using a two-by-two comparison of neos™ and clinical reference classifications. Sensitivity and specificity are reported with two-sided 95% exact Clopper-Pearson confidence intervals. An endpoint meets its prespecified success criterion when the lower confidence bounds for both sensitivity and specificity exceed 65%. There is no composite success criterion across the three endpoints and no multiplicity adjustment. Agreement on the affected eye is summarized descriptively among participants classified as suppression-present by both methods.

Validation recruitment ends when all prespecified reference-class requirements are met: at least 41 evaluable participants without sensory fusion, 73 with stereopsis, 73 without stereopsis and 22 with suppression. An operational review at approximately 80 evaluable participants, or earlier if indicated, examines reference-class prevalence to update enrolment projections. It does not examine agreement between neos™ and the reference assessment. No formal interim efficacy or futility analysis is planned.

Secondary analyses compare neos™ fusion break-off angles with clinical prism-bar measurements using Bland-Altman analysis. Agreement in stereopsis severity categories is assessed using weighted Cohen's kappa. Suppression-related outputs and other eye-movement, pupil and visual-field measurements are characterized descriptively, with exploratory comparisons across clinically defined groups. No formal performance goals apply to these secondary analyses.

Primary analyses include participants with conclusive results from both methods for the endpoint concerned. Missing classifications are not imputed. Participants may contribute to one endpoint analysis even if another endpoint is not evaluable. Evaluability rates and reasons for missing or inconclusive results are reported. Safety assessments include validation-phase participants who begin the neos™ examination. No routine follow-up visit is planned; ongoing adverse events are followed as clinically appropriate until resolution or stabilization.

연구 유형

중재적

등록 (추정된)

184

단계

  • 해당 없음

연락처 및 위치

이 섹션에서는 연구를 수행하는 사람들의 연락처 정보와 이 연구가 수행되는 장소에 대한 정보를 제공합니다.

연구 연락처

참여기준

연구원은 적격성 기준이라는 특정 설명에 맞는 사람을 찾습니다. 이러한 기준의 몇 가지 예는 개인의 일반적인 건강 상태 또는 이전 치료입니다.

자격 기준

공부할 수 있는 나이

3년 이상 (어린이, 성인, 고령자)

건강한 자원 봉사자를 받아들입니다

아니

연구 대상 성별

모두

설명

Inclusion Criteria:

  • Patients scheduled to undergo, or having undergone, a clinical binocularity assessment at the investigational site on the same day.
  • Age ≥3 years at the time of consent.
  • Ability to understand and comply with the examination, in the investigator's opinion.
  • Written informed consent provided by the participant and/or legal representative.

Exclusion Criteria:

  • Best-corrected visual acuity worse than 0.2 decimal (0.7 logMAR) in either eye.
  • Refractive error beyond the range that can be corrected by the system, including lens inserts and the use of contact lenses.

공부 계획

이 섹션에서는 연구 설계 방법과 연구가 측정하는 내용을 포함하여 연구 계획에 대한 세부 정보를 제공합니다.

연구는 어떻게 설계됩니까?

디자인 세부사항

  • 주 목적: 특수 증상
  • 할당: 해당 없음
  • 중재 모델: 단일 그룹 할당
  • 마스킹: 없음(오픈 라벨)

무기와 개입

참가자 그룹 / 팔
개입 / 치료
실험적: neos™ Assessment and Clinical Reference Examination

All participants undergo the investigational neos™ assessment and a standard clinical binocular vision examination during the same visit. The clinical examination serves as the reference standard for comparing classifications of sensory fusion, stereopsis and central suppression, and for assessing agreement in fusion-related measurements.

Standard clinical binocular vision examination performed by a trained healthcare professional. Assessments may include prism bar testing, Bagolini striated lenses, Worth 4-Dot testing and standardized stereotests, selected according to clinical findings and participant cooperation. Suitable reference information is obtained for each primary outcome. The examination lasts approximately 30 minutes.

연구는 무엇을 측정합니까?

주요 결과 측정

결과 측정
측정값 설명
기간
Sensitivity and Specificity of neos™ for Detecting Sensory Fusion
기간: During the single study visit (approximately 60 minutes).

Sensitivity and specificity of the neos™ sensory fusion classification (present/absent) compared with the clinical reference classification. Reference sensory fusion is present when binocular single perception is demonstrated using Bagolini striated lenses or Worth 4-Dot testing. Performance is calculated from paired classifications and reported with two-sided 95% exact Clopper-Pearson confidence intervals.

During the single study visit (approximately 60 minutes).
Sensitivity and Specificity of neos™ for Detecting Stereopsis
기간: During the single study visit (approximately 60 minutes).

Sensitivity and specificity of the neos™ stereopsis classification (present/absent) compared with standard clinical stereotesting. For both methods, stereopsis is classified as present when stereoscopic disparity of 600 arcseconds or finer is detected. Performance is calculated from paired classifications and reported with two-sided 95% exact Clopper-Pearson confidence intervals.

During the single study visit (approximately 60 minutes).
Sensitivity and Specificity of neos™ for Detecting Central Suppression
기간: During the single study visit (approximately 60 minutes).

Sensitivity and specificity of the neos™ central (foveal) suppression classification (present/absent) compared with the clinical reference classification. The reference uses a prespecified hierarchical rule: suppression is absent when stereopsis or sensory fusion is present. When both are absent, suppression is present if clinical testing demonstrates failure to perceive input from one eye; otherwise, it is absent. Performance is reported with two-sided 95% exact Clopper-Pearson confidence intervals.

During the single study visit (approximately 60 minutes).

공동 작업자 및 조사자

여기에서 이 연구와 관련된 사람과 조직을 찾을 수 있습니다.

스폰서

협력자

수사관

  • 수석 연구원: Muriel Dysli, MD PhD, Kantonsspital Aarau

연구 기록 날짜

이 날짜는 ClinicalTrials.gov에 대한 연구 기록 및 요약 결과 제출의 진행 상황을 추적합니다. 연구 기록 및 보고된 결과는 공개 웹사이트에 게시되기 전에 특정 품질 관리 기준을 충족하는지 확인하기 위해 국립 의학 도서관(NLM)에서 검토합니다.

연구 주요 날짜

연구 시작 (추정된)

2027년 1월 1일

기본 완료 (추정된)

2027년 6월 1일

연구 완료 (추정된)

2027년 6월 1일

연구 등록 날짜

최초 제출

2026년 10월 30일

QC 기준을 충족하는 최초 제출

2026년 10월 30일

처음 게시됨 (실제)

2026년 11월 5일

연구 기록 업데이트

마지막 업데이트 게시됨 (실제)

2026년 11월 5일

QC 기준을 충족하는 마지막 업데이트 제출

2026년 10월 30일

마지막으로 확인됨

2026년 10월 1일

추가 정보

이 연구와 관련된 용어

기타 연구 ID 번호

  • CI-002
  • 2026-D0075 (기타 식별자: Swissethics)

개별 참가자 데이터(IPD) 계획

개별 참가자 데이터(IPD)를 공유할 계획입니까?

아니요

약물 및 장치 정보, 연구 문서

미국 FDA 규제 의약품 연구

아니

미국 FDA 규제 기기 제품 연구

아니

미국에서 제조되어 미국에서 수출되는 제품

아니

이 정보는 변경 없이 clinicaltrials.gov 웹사이트에서 직접 가져온 것입니다. 귀하의 연구 세부 정보를 변경, 제거 또는 업데이트하도록 요청하는 경우 register@clinicaltrials.gov. 문의하십시오. 변경 사항이 clinicaltrials.gov에 구현되는 즉시 저희 웹사이트에도 자동으로 업데이트됩니다. .