- ICH GCP
- 미국 임상 시험 레지스트리
- 임상시험 NCT03315845
Neuraxial Anaesthesia: Does BMI Relate to Ease of Neuraxial Anaesthesia?
Neuraxial Anaesthesia: Does BMI Relate to Palpability of Bony Landmarks and Are Standard Needles a Suitable First Choice in Patients With BMI>30kg/m2
연구 개요
상태
상세 설명
Complications rates including failure are higher in obese patients undergoing anaesthesia procedures. Anaesthetists have adopted the use of ultrasound to assist in overcoming these difficulties. Neuraxial ultrasound is proving to be beneficial in those patients in whom identification of interspinous spaces is difficult and most of these patients are obese.
In our institution, there is a 'standard practice' for neuraxial procedures, with a 'standard' needle used for first attempts (Whitacre 25G 90mm for spinal, Tuohy 18G 80mm for epidural). If the operator has not reached the desired space (spinal or epidural) with the needle inserted to 8cm, a longer needle is then considered for further attempts. This exposes the patient to at least one extra neuraxial needle insertion. Studies have shown that increased needle insertions and redirections are associated with increased complications.
We hypothesised that a large number of patients with BMI>30kg/m2 would have a depth of spinal/epidural space that is greater than the length of the 'standard' needle used. Therefore we suggest that practice should change to use the longer needle or a combined spinal-epidural on the first attempt in these patients.
To test our hypothesis, we will assess the ease of palpation of the following anatomical landmarks: anterior and posterior iliac crests; lumbar spinous processes; scapulae; and sacral cornua. We will then perform neuraxial sonography of the lumbar spine, measuring depth to epidural space. Finally we will measure waist circumference in those patients with BMI <30kg/m2.
연구 유형
등록 (예상)
연락처 및 위치
참여기준
자격 기준
공부할 수 있는 나이
건강한 자원 봉사자를 받아들입니다
연구 대상 성별
샘플링 방법
연구 인구
설명
Inclusion Criteria:
- Recorded BMI >30kg/m2; ability to give consent; non-emergency cases.
Exclusion Criteria:
- Previous metal work to lumbar spine.
공부 계획
연구는 어떻게 설계됩니까?
디자인 세부사항
연구는 무엇을 측정합니까?
주요 결과 측정
결과 측정 |
측정값 설명 |
기간 |
---|---|---|
Palpability of bony landmarks for neuraxial anaesthesia
기간: 4 months
|
The percentage of patients with BMI>30kg/m2 who have difficult or impalpable bony landmarks including: lumbar spinous processes; anterior and posterior iliac spines; scapulae; and sacral cornua.
|
4 months
|
2차 결과 측정
결과 측정 |
측정값 설명 |
기간 |
---|---|---|
Ultrasonographic distance from skin to posterior epidural complex
기간: 4 months
|
To use sonography to measure the distance from skin to the dural complex in these patients and quantify the percentage whose distance is greater than the length of the standard needle.
|
4 months
|
공동 작업자 및 조사자
수사관
- 연구 책임자: Kevin McKeating, National Maternity Hospital, Ireland
간행물 및 유용한 링크
일반 간행물
- Balki M, Lee Y, Halpern S, Carvalho JC. Ultrasound imaging of the lumbar spine in the transverse plane: the correlation between estimated and actual depth to the epidural space in obese parturients. Anesth Analg. 2009 Jun;108(6):1876-81. doi: 10.1213/ane.0b013e3181a323f6.
- Arzola C, Mikhael R, Margarido C, Carvalho JC. Spinal ultrasound versus palpation for epidural catheter insertion in labour: A randomised controlled trial. Eur J Anaesthesiol. 2015 Jul;32(7):499-505. doi: 10.1097/EJA.0000000000000119.
- Ansari T, Yousef A, El Gamassy A, Fayez M. Ultrasound-guided spinal anaesthesia in obstetrics: is there an advantage over the landmark technique in patients with easily palpable spines? Int J Obstet Anesth. 2014 Aug;23(3):213-6. doi: 10.1016/j.ijoa.2014.03.001. Epub 2014 Mar 12.
- Srinivasan KK, Lee PJ, Iohom G. Ultrasound for neuraxial blockade. Med Ultrason. 2014 Dec;16(4):356-63.
- Grau T, Leipold RW, Delorme S, Martin E, Motsch J. Ultrasound imaging of the thoracic epidural space. Reg Anesth Pain Med. 2002 Mar-Apr;27(2):200-6. doi: 10.1053/rapm.2002.29239.
- Carnie J, Boden J, Gao Smith F. Prediction by computerised tomography of distance from skin to epidural space during thoracic epidural insertion. Anaesthesia. 2002 Jul;57(7):701-4. doi: 10.1046/j.1365-2044.2002.02572_4.x.
- Gnaho A, Nguyen V, Villevielle T, Frota M, Marret E, Gentili ME. Assessing the depth of the subarachnoid space by ultrasound. Rev Bras Anestesiol. 2012 Jul;62(4):520-30. doi: 10.1016/S0034-7094(12)70150-2.
- Seligman KM, Weiniger CF, Carvalho B. The Accuracy of a Handheld Ultrasound Device for Neuraxial Depth and Landmark Assessment: A Prospective Cohort Trial. Anesth Analg. 2018 Jun;126(6):1995-1998. doi: 10.1213/ANE.0000000000002407.
연구 기록 날짜
연구 주요 날짜
연구 시작 (예상)
기본 완료 (예상)
연구 완료 (예상)
연구 등록 날짜
최초 제출
QC 기준을 충족하는 최초 제출
처음 게시됨 (실제)
연구 기록 업데이트
마지막 업데이트 게시됨 (실제)
QC 기준을 충족하는 마지막 업데이트 제출
마지막으로 확인됨
추가 정보
이 연구와 관련된 용어
추가 관련 MeSH 약관
기타 연구 ID 번호
- NationalMHI
개별 참가자 데이터(IPD) 계획
개별 참가자 데이터(IPD)를 공유할 계획입니까?
약물 및 장치 정보, 연구 문서
미국 FDA 규제 의약품 연구
미국 FDA 규제 기기 제품 연구
이 정보는 변경 없이 clinicaltrials.gov 웹사이트에서 직접 가져온 것입니다. 귀하의 연구 세부 정보를 변경, 제거 또는 업데이트하도록 요청하는 경우 register@clinicaltrials.gov. 문의하십시오. 변경 사항이 clinicaltrials.gov에 구현되는 즉시 저희 웹사이트에도 자동으로 업데이트됩니다. .