Accuracy of MRI-based Patients Matched Instruments vs Jig-based Instruments in Total Knee Arthroplasty (TKA)
21 februari 2013 bijgewerkt door: Mahidol University
Accuracy of MRI-based Patients Matched Instruments and Jig-based Instruments in Total Knee Arthroplasty
Total knee arthroplasty (TKA) is the common and effective procedure for treatment of end-staged knee osteoarthritis.
Postoperative alignment of TKA is one of the important factors which effects on survival of prosthesis.
High percentage of misalignment has been reported in conventional technique with using the jig based instruments.
Several methods and devices were established to solve this problem.
Customized or patient matched instruments were the novel technology that made from magnetic resonance imaging (MRI) of lower limb.
With using special software to calculate the alignment axis, it was thought that accurate alignment can be achieved by using this instruments.
Therefore, the study aimed to compare the accuracy of MRI based patient matched instruments and jig based instruments in TKA.
Studie Overzicht
Toestand
Voltooid
Conditie
Interventie / Behandeling
Studietype
Ingrijpend
Inschrijving (Werkelijk)
80
Fase
- Niet toepasbaar
Deelname Criteria
Onderzoekers zoeken naar mensen die aan een bepaalde beschrijving voldoen, de zogenaamde geschiktheidscriteria. Enkele voorbeelden van deze criteria zijn iemands algemene gezondheidstoestand of eerdere behandelingen.
Geschiktheidscriteria
Leeftijden die in aanmerking komen voor studie
40 jaar tot 85 jaar (Volwassen, Oudere volwassene)
Accepteert gezonde vrijwilligers
Nee
Geslachten die in aanmerking komen voor studie
Allemaal
Beschrijving
Inclusion Criteria:
- Patients diagnosed primary osteoarthritis of knee and planned to undergo total knee arthroplasty
Exclusion Criteria:
- Previous complex surgery of the affected knee
- Metalic implant in the affected lower limb
- Patients who unable or contraindicated to perform MRI
- Extra-articular deformities of the affected lower limb
- Extensive bone loss of distal femur or/and proximal tibia
- More than 30 degrees of knee flexion contracture
- Unable to perform TKA within 12 weeks after MRI
Studie plan
Dit gedeelte bevat details van het studieplan, inclusief hoe de studie is opgezet en wat de studie meet.
Hoe is de studie opgezet?
Ontwerpdetails
- Primair doel: Behandeling
- Toewijzing: Gerandomiseerd
- Interventioneel model: Parallelle opdracht
- Masker: Enkel
Wapens en interventies
Deelnemersgroep / Arm |
Interventie / Behandeling |
|---|---|
|
Experimenteel: Group 1
Patient matched instruments
|
The patients undergo TKA with using patient matched instruments
Andere namen:
|
|
Experimenteel: Group 2
Jig based instruments
|
The patients undergo TKA with using jig based instruments
Andere namen:
|
Wat meet het onderzoek?
Primaire uitkomstmaten
Uitkomstmaat |
Tijdsspanne |
|---|---|
|
The alignment of mechanical axis after TKA
Tijdsspanne: Within 1 month after operation
|
Within 1 month after operation
|
Secundaire uitkomstmaten
Uitkomstmaat |
Tijdsspanne |
|---|---|
|
The alignment of femoral and tibial components after TKA
Tijdsspanne: Within 1 month after operation
|
Within 1 month after operation
|
Medewerkers en onderzoekers
Hier vindt u mensen en organisaties die betrokken zijn bij dit onderzoek.
Sponsor
Onderzoekers
- Hoofdonderzoeker: Keerati Charoencholvanich, MD, Mahidol University
Publicaties en nuttige links
De persoon die verantwoordelijk is voor het invoeren van informatie over het onderzoek stelt deze publicaties vrijwillig ter beschikking. Dit kan gaan over alles wat met het onderzoek te maken heeft.
Studie record data
Deze datums volgen de voortgang van het onderzoeksdossier en de samenvatting van de ingediende resultaten bij ClinicalTrials.gov. Studieverslagen en gerapporteerde resultaten worden beoordeeld door de National Library of Medicine (NLM) om er zeker van te zijn dat ze voldoen aan specifieke kwaliteitscontrolenormen voordat ze op de openbare website worden geplaatst.
Bestudeer belangrijke data
Studie start
1 april 2011
Primaire voltooiing (Werkelijk)
1 oktober 2011
Studie voltooiing (Werkelijk)
1 oktober 2011
Studieregistratiedata
Eerst ingediend
6 oktober 2011
Eerst ingediend dat voldeed aan de QC-criteria
7 oktober 2011
Eerst geplaatst (Schatting)
10 oktober 2011
Updates van studierecords
Laatste update geplaatst (Schatting)
22 februari 2013
Laatste update ingediend die voldeed aan QC-criteria
21 februari 2013
Laatst geverifieerd
1 februari 2013
Meer informatie
Termen gerelateerd aan deze studie
Aanvullende relevante MeSH-voorwaarden
Andere studie-ID-nummers
- Si050/2554(EC2)
Deze informatie is zonder wijzigingen rechtstreeks van de website clinicaltrials.gov gehaald. Als u verzoeken heeft om uw onderzoeksgegevens te wijzigen, te verwijderen of bij te werken, neem dan contact op met register@clinicaltrials.gov. Zodra er een wijziging wordt doorgevoerd op clinicaltrials.gov, wordt deze ook automatisch bijgewerkt op onze website .