Esta página foi traduzida automaticamente e a precisão da tradução não é garantida. Por favor, consulte o versão em inglês para um texto fonte.

Accuracy of MRI-based Patients Matched Instruments vs Jig-based Instruments in Total Knee Arthroplasty (TKA)

21 de fevereiro de 2013 atualizado por: Mahidol University

Accuracy of MRI-based Patients Matched Instruments and Jig-based Instruments in Total Knee Arthroplasty

Total knee arthroplasty (TKA) is the common and effective procedure for treatment of end-staged knee osteoarthritis. Postoperative alignment of TKA is one of the important factors which effects on survival of prosthesis. High percentage of misalignment has been reported in conventional technique with using the jig based instruments. Several methods and devices were established to solve this problem. Customized or patient matched instruments were the novel technology that made from magnetic resonance imaging (MRI) of lower limb. With using special software to calculate the alignment axis, it was thought that accurate alignment can be achieved by using this instruments. Therefore, the study aimed to compare the accuracy of MRI based patient matched instruments and jig based instruments in TKA.

Visão geral do estudo

Tipo de estudo

Intervencional

Inscrição (Real)

80

Estágio

  • Não aplicável

Critérios de participação

Os pesquisadores procuram pessoas que se encaixem em uma determinada descrição, chamada de critérios de elegibilidade. Alguns exemplos desses critérios são a condição geral de saúde de uma pessoa ou tratamentos anteriores.

Critérios de elegibilidade

Idades elegíveis para estudo

40 anos a 85 anos (Adulto, Adulto mais velho)

Aceita Voluntários Saudáveis

Não

Gêneros Elegíveis para o Estudo

Tudo

Descrição

Inclusion Criteria:

  • Patients diagnosed primary osteoarthritis of knee and planned to undergo total knee arthroplasty

Exclusion Criteria:

  • Previous complex surgery of the affected knee
  • Metalic implant in the affected lower limb
  • Patients who unable or contraindicated to perform MRI
  • Extra-articular deformities of the affected lower limb
  • Extensive bone loss of distal femur or/and proximal tibia
  • More than 30 degrees of knee flexion contracture
  • Unable to perform TKA within 12 weeks after MRI

Plano de estudo

Esta seção fornece detalhes do plano de estudo, incluindo como o estudo é projetado e o que o estudo está medindo.

Como o estudo é projetado?

Detalhes do projeto

  • Finalidade Principal: Tratamento
  • Alocação: Randomizado
  • Modelo Intervencional: Atribuição Paralela
  • Mascaramento: Solteiro

Armas e Intervenções

Grupo de Participantes / Braço
Intervenção / Tratamento
Experimental: Group 1
Patient matched instruments
The patients undergo TKA with using patient matched instruments
Outros nomes:
  • The Zimmer Patient Specific Instruments System
Experimental: Group 2
Jig based instruments
The patients undergo TKA with using jig based instruments
Outros nomes:
  • Zimmer Nexgen LPS MIS system

O que o estudo está medindo?

Medidas de resultados primários

Medida de resultado
Prazo
The alignment of mechanical axis after TKA
Prazo: Within 1 month after operation
Within 1 month after operation

Medidas de resultados secundários

Medida de resultado
Prazo
The alignment of femoral and tibial components after TKA
Prazo: Within 1 month after operation
Within 1 month after operation

Colaboradores e Investigadores

É aqui que você encontrará pessoas e organizações envolvidas com este estudo.

Patrocinador

Investigadores

  • Investigador principal: Keerati Charoencholvanich, MD, Mahidol University

Publicações e links úteis

A pessoa responsável por inserir informações sobre o estudo fornece voluntariamente essas publicações. Estes podem ser sobre qualquer coisa relacionada ao estudo.

Datas de registro do estudo

Essas datas acompanham o progresso do registro do estudo e os envios de resumo dos resultados para ClinicalTrials.gov. Os registros do estudo e os resultados relatados são revisados ​​pela National Library of Medicine (NLM) para garantir que atendam aos padrões específicos de controle de qualidade antes de serem publicados no site público.

Datas Principais do Estudo

Início do estudo

1 de abril de 2011

Conclusão Primária (Real)

1 de outubro de 2011

Conclusão do estudo (Real)

1 de outubro de 2011

Datas de inscrição no estudo

Enviado pela primeira vez

6 de outubro de 2011

Enviado pela primeira vez que atendeu aos critérios de CQ

7 de outubro de 2011

Primeira postagem (Estimativa)

10 de outubro de 2011

Atualizações de registro de estudo

Última Atualização Postada (Estimativa)

22 de fevereiro de 2013

Última atualização enviada que atendeu aos critérios de controle de qualidade

21 de fevereiro de 2013

Última verificação

1 de fevereiro de 2013

Mais Informações

Termos relacionados a este estudo

Outros números de identificação do estudo

  • Si050/2554(EC2)

Essas informações foram obtidas diretamente do site clinicaltrials.gov sem nenhuma alteração. Se você tiver alguma solicitação para alterar, remover ou atualizar os detalhes do seu estudo, entre em contato com register@clinicaltrials.gov. Assim que uma alteração for implementada em clinicaltrials.gov, ela também será atualizada automaticamente em nosso site .

Ensaios clínicos em Osteoartrite do joelho

Ensaios clínicos em Patient matched instruments

Se inscrever