- ICH GCP
- Register voor klinische proeven in de VS.
- Klinische proef NCT02611947
CT Indexes of Emphysema and Airways in Healthy Volunteers: Normal Values; Relations With Gender, Height and Weight
Studie Overzicht
Gedetailleerde beschrijving
87 healthy volunteers performed consecutively a low-dose chest CT scan and pulmonary function tests:
On chest CT scans, indexes reflecting pulmonary emphysema and airways measurements have been computed by using dedicated softwares. Each of our three readers performed two reading sessions.
Relative area of lung parenchyma with attenuation value less than -960 Hounsfield Units; luminal area and wall thickness in third and fourth generations airways were recorded.
- Pulmonary function tests were performed: vital capacity, forced vital capacity , functional residual capacity, total lung capacity, residual volume, forced expiratory volume in one second, and diffusion lung capacity for carbon monoxide were recorded (either in absolute values and percentage of predicted values).
CT indexes were compared with gender, height and weight.
Studietype
Inschrijving (Werkelijk)
Contacten en locaties
Studie Locaties
-
-
-
Brussels, België, 1070
- Erasme University Hospital
-
-
Deelname Criteria
Geschiktheidscriteria
Leeftijden die in aanmerking komen voor studie
Accepteert gezonde vrijwilligers
Geslachten die in aanmerking komen voor studie
Bemonsteringsmethode
Studie Bevolking
Beschrijving
Inclusion Criteria:
- Never smoked.
- No respiratory infection in the 4 weeks before the begin of the study.
- No history of pulmonary resection.
- No active malignancy or malignancy of any organ system within the past 5 years.
Exclusion Criteria:
- no exclusion criteria
Studie plan
Hoe is de studie opgezet?
Ontwerpdetails
Cohorten en interventies
Groep / Cohort |
Interventie / Behandeling |
|---|---|
|
Healthy Volunteers
Inclusion criteria:
|
Supine chest CT scan after full inspiration. Acquisition parameters: (Topogram 35 mA 120 kV 512 mm length) 35 quality ref mAs with care-dose ON 120 kV Pitch 1.4 Rotation time 0.33 s Acquired images 64 x 0.6 mm |
Wat meet het onderzoek?
Primaire uitkomstmaten
Uitkomstmaat |
Maatregel Beschrijving |
Tijdsspanne |
|---|---|---|
|
CT index - RA960 (%)
Tijdsspanne: 4 hours
|
From acquired data, images were reconstructed using a soft algorithm.
On these soft images, the relative area of lung parenchyma with attenuation value less than -960 Hounsfield Units was computed (expressed in %), as an index representative of pulmonary emphysema extent.
|
4 hours
|
|
CT index - LA3rd (mm2)
Tijdsspanne: 4 hours
|
From acquired data, images were reconstructed using a high resolution algorithm.
On these high-resolution images, the airway lumen was measured in third generations of airways (expressed in mm2).
|
4 hours
|
|
CT index - LA4th (mm2)
Tijdsspanne: 4 hours
|
From acquired data, images were reconstructed using a high resolution algorithm.
On these high-resolution images, the airway lumen was measured in fourth generations of airways (expressed in mm2).
|
4 hours
|
|
CT index - WT3rd (mm)
Tijdsspanne: 4 hours
|
From acquired data, images were reconstructed using a high resolution algorithm.
On these high-resolution images, the airway wall was measured in third generations of airways (expressed in mm).
|
4 hours
|
|
CT index - WT4th (mm)
Tijdsspanne: 4 hours
|
From acquired data, images were reconstructed using a high resolution algorithm.
On these high-resolution images, the airway wall was measured in fourth generations of airways (expressed in mm).
|
4 hours
|
Secundaire uitkomstmaten
Uitkomstmaat |
Maatregel Beschrijving |
Tijdsspanne |
|---|---|---|
|
Pulmonary function tests - VC (l)
Tijdsspanne: 4 hours
|
Vital capacity was measured (expressed in l).
|
4 hours
|
|
Pulmonary function tests - FVC (l)
Tijdsspanne: 4 hours
|
Forced vital capacity was measured (expressed in l).
|
4 hours
|
|
Pulmonary function tests - FRC (l)
Tijdsspanne: 4 hours
|
Functional residual capacity capacity was measured (expressed in l).
|
4 hours
|
|
Pulmonary function tests - TLC (l)
Tijdsspanne: 4 hours
|
Total lung capacity was measured (expressed in l).
|
4 hours
|
|
Pulmonary function tests - RV (l)
Tijdsspanne: 4 hours
|
Residual volume was measured (expressed in l).
|
4 hours
|
|
Pulmonary function tests - FEV1 (l)
Tijdsspanne: 4 hours
|
Forced expiratory volume in one second was measured (expressed in l).
|
4 hours
|
|
Pulmonary function tests - DLCO (ml/min/ mmHg)
Tijdsspanne: 4 hours
|
Diffusion lung capacity for carbon monoxide was measured (expressed in ml/min/ mmHg)
|
4 hours
|
Medewerkers en onderzoekers
Sponsor
Publicaties en nuttige links
Algemene publicaties
- Madani A, Zanen J, de Maertelaer V, Gevenois PA. Pulmonary emphysema: objective quantification at multi-detector row CT--comparison with macroscopic and microscopic morphometry. Radiology. 2006 Mar;238(3):1036-43. doi: 10.1148/radiol.2382042196. Epub 2006 Jan 19.
- Madani A, De Maertelaer V, Zanen J, Gevenois PA. Pulmonary emphysema: radiation dose and section thickness at multidetector CT quantification--comparison with macroscopic and microscopic morphometry. Radiology. 2007 Apr;243(1):250-7. doi: 10.1148/radiol.2431060194.
- Hackx M, Bankier AA, Gevenois PA. Chronic obstructive pulmonary disease: CT quantification of airways disease. Radiology. 2012 Oct;265(1):34-48. doi: 10.1148/radiol.12111270.
- Hackx M, Gyssels E, Severo Garcia T, De Meulder I, Alard S, Bruyneel M, Van Muylem A, Ninane V, Gevenois PA. Chronic Obstructive Pulmonary Disease: CT Quantification of Airway Dimensions, Numbers of Airways to Measure, and Effect of Bronchodilation. Radiology. 2015 Dec;277(3):853-62. doi: 10.1148/radiol.2015140949. Epub 2015 May 19.
Studie record data
Bestudeer belangrijke data
Studie start
Primaire voltooiing (Werkelijk)
Studie voltooiing (Werkelijk)
Studieregistratiedata
Eerst ingediend
Eerst ingediend dat voldeed aan de QC-criteria
Eerst geplaatst (Schatting)
Updates van studierecords
Laatste update geplaatst (Schatting)
Laatste update ingediend die voldeed aan QC-criteria
Laatst geverifieerd
Meer informatie
Termen gerelateerd aan deze studie
Aanvullende relevante MeSH-voorwaarden
Andere studie-ID-nummers
- P2010/175
Deze informatie is zonder wijzigingen rechtstreeks van de website clinicaltrials.gov gehaald. Als u verzoeken heeft om uw onderzoeksgegevens te wijzigen, te verwijderen of bij te werken, neem dan contact op met register@clinicaltrials.gov. Zodra er een wijziging wordt doorgevoerd op clinicaltrials.gov, wordt deze ook automatisch bijgewerkt op onze website .