CT Indexes of Emphysema and Airways in Healthy Volunteers: Normal Values; Relations With Gender, Height and Weight
A tanulmány áttekintése
Részletes leírás
87 healthy volunteers performed consecutively a low-dose chest CT scan and pulmonary function tests:
On chest CT scans, indexes reflecting pulmonary emphysema and airways measurements have been computed by using dedicated softwares. Each of our three readers performed two reading sessions.
Relative area of lung parenchyma with attenuation value less than -960 Hounsfield Units; luminal area and wall thickness in third and fourth generations airways were recorded.
- Pulmonary function tests were performed: vital capacity, forced vital capacity , functional residual capacity, total lung capacity, residual volume, forced expiratory volume in one second, and diffusion lung capacity for carbon monoxide were recorded (either in absolute values and percentage of predicted values).
CT indexes were compared with gender, height and weight.
Tanulmány típusa
Beiratkozás (Tényleges)
Kapcsolatok és helyek
Tanulmányi helyek
-
-
-
Brussels, Belgium, 1070
- Erasme University Hospital
-
-
Részvételi kritériumok
Jogosultsági kritériumok
Tanulmányozható életkorok
Egészséges önkénteseket fogad
Tanulmányozható nemek
Mintavételi módszer
Tanulmányi populáció
Leírás
Inclusion Criteria:
- Never smoked.
- No respiratory infection in the 4 weeks before the begin of the study.
- No history of pulmonary resection.
- No active malignancy or malignancy of any organ system within the past 5 years.
Exclusion Criteria:
- no exclusion criteria
Tanulási terv
Hogyan készül a tanulmány?
Tervezési részletek
Kohorszok és beavatkozások
Csoport / Kohorsz |
Beavatkozás / kezelés |
|---|---|
|
Healthy Volunteers
Inclusion criteria:
|
Supine chest CT scan after full inspiration. Acquisition parameters: (Topogram 35 mA 120 kV 512 mm length) 35 quality ref mAs with care-dose ON 120 kV Pitch 1.4 Rotation time 0.33 s Acquired images 64 x 0.6 mm |
Mit mér a tanulmány?
Elsődleges eredményintézkedések
Eredménymérő |
Intézkedés leírása |
Időkeret |
|---|---|---|
|
CT index - RA960 (%)
Időkeret: 4 hours
|
From acquired data, images were reconstructed using a soft algorithm.
On these soft images, the relative area of lung parenchyma with attenuation value less than -960 Hounsfield Units was computed (expressed in %), as an index representative of pulmonary emphysema extent.
|
4 hours
|
|
CT index - LA3rd (mm2)
Időkeret: 4 hours
|
From acquired data, images were reconstructed using a high resolution algorithm.
On these high-resolution images, the airway lumen was measured in third generations of airways (expressed in mm2).
|
4 hours
|
|
CT index - LA4th (mm2)
Időkeret: 4 hours
|
From acquired data, images were reconstructed using a high resolution algorithm.
On these high-resolution images, the airway lumen was measured in fourth generations of airways (expressed in mm2).
|
4 hours
|
|
CT index - WT3rd (mm)
Időkeret: 4 hours
|
From acquired data, images were reconstructed using a high resolution algorithm.
On these high-resolution images, the airway wall was measured in third generations of airways (expressed in mm).
|
4 hours
|
|
CT index - WT4th (mm)
Időkeret: 4 hours
|
From acquired data, images were reconstructed using a high resolution algorithm.
On these high-resolution images, the airway wall was measured in fourth generations of airways (expressed in mm).
|
4 hours
|
Másodlagos eredményintézkedések
Eredménymérő |
Intézkedés leírása |
Időkeret |
|---|---|---|
|
Pulmonary function tests - VC (l)
Időkeret: 4 hours
|
Vital capacity was measured (expressed in l).
|
4 hours
|
|
Pulmonary function tests - FVC (l)
Időkeret: 4 hours
|
Forced vital capacity was measured (expressed in l).
|
4 hours
|
|
Pulmonary function tests - FRC (l)
Időkeret: 4 hours
|
Functional residual capacity capacity was measured (expressed in l).
|
4 hours
|
|
Pulmonary function tests - TLC (l)
Időkeret: 4 hours
|
Total lung capacity was measured (expressed in l).
|
4 hours
|
|
Pulmonary function tests - RV (l)
Időkeret: 4 hours
|
Residual volume was measured (expressed in l).
|
4 hours
|
|
Pulmonary function tests - FEV1 (l)
Időkeret: 4 hours
|
Forced expiratory volume in one second was measured (expressed in l).
|
4 hours
|
|
Pulmonary function tests - DLCO (ml/min/ mmHg)
Időkeret: 4 hours
|
Diffusion lung capacity for carbon monoxide was measured (expressed in ml/min/ mmHg)
|
4 hours
|
Együttműködők és nyomozók
Szponzor
Publikációk és hasznos linkek
Általános kiadványok
- Madani A, Zanen J, de Maertelaer V, Gevenois PA. Pulmonary emphysema: objective quantification at multi-detector row CT--comparison with macroscopic and microscopic morphometry. Radiology. 2006 Mar;238(3):1036-43. doi: 10.1148/radiol.2382042196. Epub 2006 Jan 19.
- Madani A, De Maertelaer V, Zanen J, Gevenois PA. Pulmonary emphysema: radiation dose and section thickness at multidetector CT quantification--comparison with macroscopic and microscopic morphometry. Radiology. 2007 Apr;243(1):250-7. doi: 10.1148/radiol.2431060194.
- Hackx M, Bankier AA, Gevenois PA. Chronic obstructive pulmonary disease: CT quantification of airways disease. Radiology. 2012 Oct;265(1):34-48. doi: 10.1148/radiol.12111270.
- Hackx M, Gyssels E, Severo Garcia T, De Meulder I, Alard S, Bruyneel M, Van Muylem A, Ninane V, Gevenois PA. Chronic Obstructive Pulmonary Disease: CT Quantification of Airway Dimensions, Numbers of Airways to Measure, and Effect of Bronchodilation. Radiology. 2015 Dec;277(3):853-62. doi: 10.1148/radiol.2015140949. Epub 2015 May 19.
Tanulmányi rekorddátumok
Tanulmány főbb dátumok
Tanulmány kezdete
Elsődleges befejezés (Tényleges)
A tanulmány befejezése (Tényleges)
Tanulmányi regisztráció dátumai
Először benyújtva
Először nyújtották be, amely megfelel a minőségbiztosítási kritériumoknak
Első közzététel (Becslés)
Tanulmányi rekordok frissítései
Utolsó frissítés közzétéve (Becslés)
Az utolsó frissítés elküldve, amely megfelel a minőségbiztosítási kritériumoknak
Utolsó ellenőrzés
Több információ
A tanulmányhoz kapcsolódó kifejezések
További vonatkozó MeSH feltételek
Egyéb vizsgálati azonosító számok
- P2010/175
Ezt az információt közvetlenül a clinicaltrials.gov webhelyről szereztük be, változtatás nélkül. Ha bármilyen kérése van vizsgálati adatainak módosítására, eltávolítására vagy frissítésére, kérjük, írjon a következő címre: register@clinicaltrials.gov. Amint a változás bevezetésre kerül a clinicaltrials.gov oldalon, ez a webhelyünkön is automatikusan frissül. .