CT Indexes of Emphysema and Airways in Healthy Volunteers: Normal Values; Relations With Gender, Height and Weight

19 november 2015 uppdaterad av: Erasme University Hospital
Various indexes have been proposed to quantify both pulmonary emphysema and airways disease on chest CT scans. It is unknown whether these indexes should be consider in absolute values or as compared to predicted normal values. The purposes of the present study is thus : a) to measure these indexes at CT in healthy volunteers; b) to investigate their relations with gender, height and weight.

Studieöversikt

Status

Avslutad

Betingelser

Intervention / Behandling

Detaljerad beskrivning

87 healthy volunteers performed consecutively a low-dose chest CT scan and pulmonary function tests:

  1. On chest CT scans, indexes reflecting pulmonary emphysema and airways measurements have been computed by using dedicated softwares. Each of our three readers performed two reading sessions.

    Relative area of lung parenchyma with attenuation value less than -960 Hounsfield Units; luminal area and wall thickness in third and fourth generations airways were recorded.

  2. Pulmonary function tests were performed: vital capacity, forced vital capacity , functional residual capacity, total lung capacity, residual volume, forced expiratory volume in one second, and diffusion lung capacity for carbon monoxide were recorded (either in absolute values and percentage of predicted values).

CT indexes were compared with gender, height and weight.

Studietyp

Observationell

Inskrivning (Faktisk)

87

Kontakter och platser

Det här avsnittet innehåller kontaktuppgifter för dem som genomför studien och information om var denna studie genomförs.

Studieorter

      • Brussels, Belgien, 1070
        • Erasme University Hospital

Deltagandekriterier

Forskare letar efter personer som passar en viss beskrivning, så kallade behörighetskriterier. Några exempel på dessa kriterier är en persons allmänna hälsotillstånd eller tidigare behandlingar.

Urvalskriterier

Åldrar som är berättigade till studier

18 år och äldre (Vuxen, Äldre vuxen)

Tar emot friska volontärer

Ja

Kön som är behöriga för studier

Allt

Testmetod

Icke-sannolikhetsprov

Studera befolkning

Healthy Volunteers

Beskrivning

Inclusion Criteria:

  • Never smoked.
  • No respiratory infection in the 4 weeks before the begin of the study.
  • No history of pulmonary resection.
  • No active malignancy or malignancy of any organ system within the past 5 years.

Exclusion Criteria:

  • no exclusion criteria

Studieplan

Det här avsnittet ger detaljer om studieplanen, inklusive hur studien är utformad och vad studien mäter.

Hur är studien utformad?

Designdetaljer

Kohorter och interventioner

Grupp / Kohort
Intervention / Behandling
Healthy Volunteers

Inclusion criteria:

  1. Aged 18 or more.
  2. Never smoked.
  3. No respiratory infection in the 4 weeks before the begin of the study.
  4. No history of pulmonary resection.
  5. No active malignancy or malignancy of any organ system within the past 5 years.

Supine chest CT scan after full inspiration. Acquisition parameters: (Topogram 35 mA 120 kV 512 mm length)

35 quality ref mAs with care-dose ON 120 kV Pitch 1.4 Rotation time 0.33 s Acquired images 64 x 0.6 mm

Vad mäter studien?

Primära resultatmått

Resultatmått
Åtgärdsbeskrivning
Tidsram
CT index - RA960 (%)
Tidsram: 4 hours
From acquired data, images were reconstructed using a soft algorithm. On these soft images, the relative area of lung parenchyma with attenuation value less than -960 Hounsfield Units was computed (expressed in %), as an index representative of pulmonary emphysema extent.
4 hours
CT index - LA3rd (mm2)
Tidsram: 4 hours
From acquired data, images were reconstructed using a high resolution algorithm. On these high-resolution images, the airway lumen was measured in third generations of airways (expressed in mm2).
4 hours
CT index - LA4th (mm2)
Tidsram: 4 hours
From acquired data, images were reconstructed using a high resolution algorithm. On these high-resolution images, the airway lumen was measured in fourth generations of airways (expressed in mm2).
4 hours
CT index - WT3rd (mm)
Tidsram: 4 hours
From acquired data, images were reconstructed using a high resolution algorithm. On these high-resolution images, the airway wall was measured in third generations of airways (expressed in mm).
4 hours
CT index - WT4th (mm)
Tidsram: 4 hours
From acquired data, images were reconstructed using a high resolution algorithm. On these high-resolution images, the airway wall was measured in fourth generations of airways (expressed in mm).
4 hours

Sekundära resultatmått

Resultatmått
Åtgärdsbeskrivning
Tidsram
Pulmonary function tests - VC (l)
Tidsram: 4 hours
Vital capacity was measured (expressed in l).
4 hours
Pulmonary function tests - FVC (l)
Tidsram: 4 hours
Forced vital capacity was measured (expressed in l).
4 hours
Pulmonary function tests - FRC (l)
Tidsram: 4 hours
Functional residual capacity capacity was measured (expressed in l).
4 hours
Pulmonary function tests - TLC (l)
Tidsram: 4 hours
Total lung capacity was measured (expressed in l).
4 hours
Pulmonary function tests - RV (l)
Tidsram: 4 hours
Residual volume was measured (expressed in l).
4 hours
Pulmonary function tests - FEV1 (l)
Tidsram: 4 hours
Forced expiratory volume in one second was measured (expressed in l).
4 hours
Pulmonary function tests - DLCO (ml/min/ mmHg)
Tidsram: 4 hours
Diffusion lung capacity for carbon monoxide was measured (expressed in ml/min/ mmHg)
4 hours

Samarbetspartners och utredare

Det är här du hittar personer och organisationer som är involverade i denna studie.

Publikationer och användbara länkar

Den som ansvarar för att lägga in information om studien tillhandahåller frivilligt dessa publikationer. Dessa kan handla om allt som har med studien att göra.

Studieavstämningsdatum

Dessa datum spårar framstegen för inlämningar av studieposter och sammanfattande resultat till ClinicalTrials.gov. Studieposter och rapporterade resultat granskas av National Library of Medicine (NLM) för att säkerställa att de uppfyller specifika kvalitetskontrollstandarder innan de publiceras på den offentliga webbplatsen.

Studera stora datum

Studiestart

1 oktober 2010

Primärt slutförande (Faktisk)

1 juni 2011

Avslutad studie (Faktisk)

1 juni 2011

Studieregistreringsdatum

Först inskickad

30 oktober 2015

Först inskickad som uppfyllde QC-kriterierna

19 november 2015

Första postat (Uppskatta)

23 november 2015

Uppdateringar av studier

Senaste uppdatering publicerad (Uppskatta)

23 november 2015

Senaste inskickade uppdateringen som uppfyllde QC-kriterierna

19 november 2015

Senast verifierad

1 november 2015

Mer information

Termer relaterade till denna studie

Denna information hämtades direkt från webbplatsen clinicaltrials.gov utan några ändringar. Om du har några önskemål om att ändra, ta bort eller uppdatera dina studieuppgifter, vänligen kontakta register@clinicaltrials.gov. Så snart en ändring har implementerats på clinicaltrials.gov, kommer denna att uppdateras automatiskt även på vår webbplats .

Kliniska prövningar på Friska

Kliniska prövningar på Low-dose chest CT scans

3
Prenumerera