- ICH GCP
- Register voor klinische proeven in de VS.
- Klinische proef NCT07645768
Is Anterior Reversed Proximal Humeral Locking Plate System (PHILOS) a Safe Alternative to Conventional Posterior Double Plating in Extra-Articular Distal Shaft Humeral Fractures
Is Anterior Reversed Proximal Humeral Locking Plate System (PHILOS) a Safe Alternative to Conventional Posterior Double Plating in Extra-Articular Distal Shaft Humeral Fractures: A Randomized Controlled Trial
Extra-articular distal-third humeral shaft fractures are difficult to treat because stable fixation must be achieved while minimizing soft-tissue injury and the risk of nerve damage. Posterior double plating is a commonly used technique but requires extensive surgical exposure and routine handling of the radial and ulnar nerves. Anterior reversed proximal humeral locking plate system (PHILOS) fixation has emerged as a potential alternative that may provide adequate stability with less soft-tissue disruption.
This randomized controlled trial compares anterior reversed PHILOS plating with conventional posterior double plating in adult patients with extra-articular distal-third humeral shaft fractures. The study evaluates functional outcome using the Mayo Elbow Performance Score (MEPS) as primary outcome. Sexondary outcomes include: fracture union, operative parameters, range of motion, and complications including nerve injury, infection, and postoperative stiffness.
Studie Overzicht
Toestand
Conditie
Interventie / Behandeling
Studietype
Inschrijving (Geschat)
Fase
- Niet toepasbaar
Contacten en locaties
Studie Locaties
-
-
-
Cairo, Egypte
- Trauma and Orthopedic department, Faculty of Medicine, Cairo University
-
-
Deelname Criteria
Geschiktheidscriteria
Leeftijden die in aanmerking komen voor studie
- Volwassen
- Oudere volwassene
Accepteert gezonde vrijwilligers
Beschrijving
Inclusion Criteria:
- Adults aged 18 years or older.
- Acute extra-articular distal humeral shaft fracture.
- AO/OTA type 12-A (simple) or 12-B (wedge) fracture.
- Closed fracture.
- Isolated injury.
- Presentation within 14 days of injury.
- Ability to provide informed consent and comply with follow-up.
Exclusion Criteria:
- Open fractures.
- Pathological fractures.
- Previous surgery on the ipsilateral humerus.
- Polytrauma requiring staged fixation.
- Contraindication to general anesthesia.
- Inability to complete the required follow-up period.
Studie plan
Hoe is de studie opgezet?
Ontwerpdetails
- Primair doel: Behandeling
- Toewijzing: Gerandomiseerd
- Interventioneel model: Parallelle opdracht
- Masker: Enkel
Wapens en interventies
Deelnemersgroep / Arm |
Interventie / Behandeling |
|---|---|
|
Experimenteel: Anterior Reversed PHILOS Plating
Patients with extra-articular distal-third humeral shaft fractures treated using an anterior approach and fixation with a reversed Proximal Humeral Internal Locking System (PHILOS) plate.
|
Fixation of extra-articular distal-third humeral shaft fractures using a reversed proximal humeral internal locking system (PHILOS) plate applied to the anterior surface of the humerus through an anterior approach.
The construct was secured with locking screws proximal and distal to the fracture site.
|
|
Experimenteel: Posterior Double Plating
Patients with extra-articular distal-third humeral shaft fractures treated using a posterior approach and fixation with orthogonal double plates applied medially and posterolaterally.
|
Fixation of extra-articular distal-third humeral shaft fractures through a posterior approach using orthogonal double plates applied medially and posterolaterally after fracture reduction.
Both radial and ulnar nerves were identified and protected during the procedure.
|
Wat meet het onderzoek?
Primaire uitkomstmaten
Uitkomstmaat |
Maatregel Beschrijving |
Tijdsspanne |
|---|---|---|
|
Mayo Elbow Performance Score (MEPS)
Tijdsspanne: 24 months after surgery
|
pain (45 points), range of motion (20 points), stability (10 points), and daily functional tasks (25 points).
Total maximum score is 100 meaning best outcome and total minimum score is 10 indicating worst outcome
|
24 months after surgery
|
Secundaire uitkomstmaten
Uitkomstmaat |
Tijdsspanne |
|---|---|
|
Operatieve tijd
Tijdsspanne: Intraoperatief
|
Intraoperatief
|
|
Fracture Union
Tijdsspanne: Upto 24 months after surgery
|
Upto 24 months after surgery
|
|
Nerve injury complications
Tijdsspanne: Immediately postoperative
|
Immediately postoperative
|
Medewerkers en onderzoekers
Sponsor
Studie record data
Bestudeer belangrijke data
Studie start (Werkelijk)
Primaire voltooiing (Werkelijk)
Studie voltooiing (Geschat)
Studieregistratiedata
Eerst ingediend
Eerst ingediend dat voldeed aan de QC-criteria
Eerst geplaatst (Werkelijk)
Updates van studierecords
Laatste update geplaatst (Werkelijk)
Laatste update ingediend die voldeed aan QC-criteria
Laatst geverifieerd
Meer informatie
Termen gerelateerd aan deze studie
Aanvullende relevante MeSH-voorwaarden
Andere studie-ID-nummers
- N-275-2025
Plan Individuele Deelnemersgegevens (IPD)
Bent u van plan om gegevens van individuele deelnemers (IPD) te delen?
Informatie over medicijnen en apparaten, studiedocumenten
Bestudeert een door de Amerikaanse FDA gereguleerd geneesmiddel
Bestudeert een door de Amerikaanse FDA gereguleerd apparaatproduct
Deze informatie is zonder wijzigingen rechtstreeks van de website clinicaltrials.gov gehaald. Als u verzoeken heeft om uw onderzoeksgegevens te wijzigen, te verwijderen of bij te werken, neem dan contact op met register@clinicaltrials.gov. Zodra er een wijziging wordt doorgevoerd op clinicaltrials.gov, wordt deze ook automatisch bijgewerkt op onze website .