Esta página foi traduzida automaticamente e a precisão da tradução não é garantida. Por favor, consulte o versão em inglês para um texto fonte.

Is Anterior Reversed Proximal Humeral Locking Plate System (PHILOS) a Safe Alternative to Conventional Posterior Double Plating in Extra-Articular Distal Shaft Humeral Fractures

11 de junho de 2026 atualizado por: Mostafa Ahmed Shawky Mohamed, Cairo University

Is Anterior Reversed Proximal Humeral Locking Plate System (PHILOS) a Safe Alternative to Conventional Posterior Double Plating in Extra-Articular Distal Shaft Humeral Fractures: A Randomized Controlled Trial

Extra-articular distal-third humeral shaft fractures are difficult to treat because stable fixation must be achieved while minimizing soft-tissue injury and the risk of nerve damage. Posterior double plating is a commonly used technique but requires extensive surgical exposure and routine handling of the radial and ulnar nerves. Anterior reversed proximal humeral locking plate system (PHILOS) fixation has emerged as a potential alternative that may provide adequate stability with less soft-tissue disruption.

This randomized controlled trial compares anterior reversed PHILOS plating with conventional posterior double plating in adult patients with extra-articular distal-third humeral shaft fractures. The study evaluates functional outcome using the Mayo Elbow Performance Score (MEPS) as primary outcome. Sexondary outcomes include: fracture union, operative parameters, range of motion, and complications including nerve injury, infection, and postoperative stiffness.

Visão geral do estudo

Status

Ativo, não recrutando

Condições

Tipo de estudo

Intervencional

Inscrição (Estimado)

68

Estágio

  • Não aplicável

Contactos e Locais

Esta seção fornece os detalhes de contato para aqueles que conduzem o estudo e informações sobre onde este estudo está sendo realizado.

Locais de estudo

      • Cairo, Egito
        • Trauma and Orthopedic department, Faculty of Medicine, Cairo University

Critérios de participação

Os pesquisadores procuram pessoas que se encaixem em uma determinada descrição, chamada de critérios de elegibilidade. Alguns exemplos desses critérios são a condição geral de saúde de uma pessoa ou tratamentos anteriores.

Critérios de elegibilidade

Idades elegíveis para estudo

  • Adulto
  • Adulto mais velho

Aceita Voluntários Saudáveis

Não

Descrição

Inclusion Criteria:

  1. Adults aged 18 years or older.
  2. Acute extra-articular distal humeral shaft fracture.
  3. AO/OTA type 12-A (simple) or 12-B (wedge) fracture.
  4. Closed fracture.
  5. Isolated injury.
  6. Presentation within 14 days of injury.
  7. Ability to provide informed consent and comply with follow-up.

Exclusion Criteria:

  1. Open fractures.
  2. Pathological fractures.
  3. Previous surgery on the ipsilateral humerus.
  4. Polytrauma requiring staged fixation.
  5. Contraindication to general anesthesia.
  6. Inability to complete the required follow-up period.

Plano de estudo

Esta seção fornece detalhes do plano de estudo, incluindo como o estudo é projetado e o que o estudo está medindo.

Como o estudo é projetado?

Detalhes do projeto

  • Finalidade Principal: Tratamento
  • Alocação: Randomizado
  • Modelo Intervencional: Atribuição Paralela
  • Mascaramento: Solteiro

Armas e Intervenções

Grupo de Participantes / Braço
Intervenção / Tratamento
Experimental: Anterior Reversed PHILOS Plating
Patients with extra-articular distal-third humeral shaft fractures treated using an anterior approach and fixation with a reversed Proximal Humeral Internal Locking System (PHILOS) plate.
Fixation of extra-articular distal-third humeral shaft fractures using a reversed proximal humeral internal locking system (PHILOS) plate applied to the anterior surface of the humerus through an anterior approach. The construct was secured with locking screws proximal and distal to the fracture site.
Experimental: Posterior Double Plating
Patients with extra-articular distal-third humeral shaft fractures treated using a posterior approach and fixation with orthogonal double plates applied medially and posterolaterally.
Fixation of extra-articular distal-third humeral shaft fractures through a posterior approach using orthogonal double plates applied medially and posterolaterally after fracture reduction. Both radial and ulnar nerves were identified and protected during the procedure.

O que o estudo está medindo?

Medidas de resultados primários

Medida de resultado
Descrição da medida
Prazo
Mayo Elbow Performance Score (MEPS)
Prazo: 24 months after surgery
pain (45 points), range of motion (20 points), stability (10 points), and daily functional tasks (25 points). Total maximum score is 100 meaning best outcome and total minimum score is 10 indicating worst outcome
24 months after surgery

Medidas de resultados secundários

Medida de resultado
Prazo
Tempo operativo
Prazo: Intraoperatório
Intraoperatório
Fracture Union
Prazo: Upto 24 months after surgery
Upto 24 months after surgery
Nerve injury complications
Prazo: Immediately postoperative
Immediately postoperative

Colaboradores e Investigadores

É aqui que você encontrará pessoas e organizações envolvidas com este estudo.

Patrocinador

Datas de registro do estudo

Essas datas acompanham o progresso do registro do estudo e os envios de resumo dos resultados para ClinicalTrials.gov. Os registros do estudo e os resultados relatados são revisados ​​pela National Library of Medicine (NLM) para garantir que atendam aos padrões específicos de controle de qualidade antes de serem publicados no site público.

Datas Principais do Estudo

Início do estudo (Real)

1 de dezembro de 2025

Conclusão Primária (Real)

1 de junho de 2026

Conclusão do estudo (Estimado)

1 de dezembro de 2026

Datas de inscrição no estudo

Enviado pela primeira vez

9 de junho de 2026

Enviado pela primeira vez que atendeu aos critérios de CQ

11 de junho de 2026

Primeira postagem (Real)

12 de junho de 2026

Atualizações de registro de estudo

Última Atualização Postada (Real)

12 de junho de 2026

Última atualização enviada que atendeu aos critérios de controle de qualidade

11 de junho de 2026

Última verificação

1 de junho de 2026

Mais Informações

Termos relacionados a este estudo

Outros números de identificação do estudo

  • N-275-2025

Plano para dados de participantes individuais (IPD)

Planeja compartilhar dados de participantes individuais (IPD)?

NÃO

Informações sobre medicamentos e dispositivos, documentos de estudo

Estuda um medicamento regulamentado pela FDA dos EUA

Não

Estuda um produto de dispositivo regulamentado pela FDA dos EUA

Não

Essas informações foram obtidas diretamente do site clinicaltrials.gov sem nenhuma alteração. Se você tiver alguma solicitação para alterar, remover ou atualizar os detalhes do seu estudo, entre em contato com register@clinicaltrials.gov. Assim que uma alteração for implementada em clinicaltrials.gov, ela também será atualizada automaticamente em nosso site .

Se inscrever