Diese Seite wurde automatisch übersetzt und die Genauigkeit der Übersetzung wird nicht garantiert. Bitte wende dich an die englische Version für einen Quelltext.

Is Anterior Reversed Proximal Humeral Locking Plate System (PHILOS) a Safe Alternative to Conventional Posterior Double Plating in Extra-Articular Distal Shaft Humeral Fractures

11. Juni 2026 aktualisiert von: Mostafa Ahmed Shawky Mohamed, Cairo University

Is Anterior Reversed Proximal Humeral Locking Plate System (PHILOS) a Safe Alternative to Conventional Posterior Double Plating in Extra-Articular Distal Shaft Humeral Fractures: A Randomized Controlled Trial

Extra-articular distal-third humeral shaft fractures are difficult to treat because stable fixation must be achieved while minimizing soft-tissue injury and the risk of nerve damage. Posterior double plating is a commonly used technique but requires extensive surgical exposure and routine handling of the radial and ulnar nerves. Anterior reversed proximal humeral locking plate system (PHILOS) fixation has emerged as a potential alternative that may provide adequate stability with less soft-tissue disruption.

This randomized controlled trial compares anterior reversed PHILOS plating with conventional posterior double plating in adult patients with extra-articular distal-third humeral shaft fractures. The study evaluates functional outcome using the Mayo Elbow Performance Score (MEPS) as primary outcome. Sexondary outcomes include: fracture union, operative parameters, range of motion, and complications including nerve injury, infection, and postoperative stiffness.

Studienübersicht

Status

Aktiv, nicht rekrutierend

Bedingungen

Studientyp

Interventionell

Einschreibung (Geschätzt)

68

Phase

  • Unzutreffend

Kontakte und Standorte

Dieser Abschnitt enthält die Kontaktdaten derjenigen, die die Studie durchführen, und Informationen darüber, wo diese Studie durchgeführt wird.

Studienorte

      • Cairo, Ägypten
        • Trauma and Orthopedic department, Faculty of Medicine, Cairo University

Teilnahmekriterien

Forscher suchen nach Personen, die einer bestimmten Beschreibung entsprechen, die als Auswahlkriterien bezeichnet werden. Einige Beispiele für diese Kriterien sind der allgemeine Gesundheitszustand einer Person oder frühere Behandlungen.

Zulassungskriterien

Studienberechtigtes Alter

  • Erwachsene
  • Älterer Erwachsener

Akzeptiert gesunde Freiwillige

Nein

Beschreibung

Inclusion Criteria:

  1. Adults aged 18 years or older.
  2. Acute extra-articular distal humeral shaft fracture.
  3. AO/OTA type 12-A (simple) or 12-B (wedge) fracture.
  4. Closed fracture.
  5. Isolated injury.
  6. Presentation within 14 days of injury.
  7. Ability to provide informed consent and comply with follow-up.

Exclusion Criteria:

  1. Open fractures.
  2. Pathological fractures.
  3. Previous surgery on the ipsilateral humerus.
  4. Polytrauma requiring staged fixation.
  5. Contraindication to general anesthesia.
  6. Inability to complete the required follow-up period.

Studienplan

Dieser Abschnitt enthält Einzelheiten zum Studienplan, einschließlich des Studiendesigns und der Messung der Studieninhalte.

Wie ist die Studie aufgebaut?

Designdetails

  • Hauptzweck: Behandlung
  • Zuteilung: Zufällig
  • Interventionsmodell: Parallele Zuordnung
  • Maskierung: Single

Waffen und Interventionen

Teilnehmergruppe / Arm
Intervention / Behandlung
Experimental: Anterior Reversed PHILOS Plating
Patients with extra-articular distal-third humeral shaft fractures treated using an anterior approach and fixation with a reversed Proximal Humeral Internal Locking System (PHILOS) plate.
Fixation of extra-articular distal-third humeral shaft fractures using a reversed proximal humeral internal locking system (PHILOS) plate applied to the anterior surface of the humerus through an anterior approach. The construct was secured with locking screws proximal and distal to the fracture site.
Experimental: Posterior Double Plating
Patients with extra-articular distal-third humeral shaft fractures treated using a posterior approach and fixation with orthogonal double plates applied medially and posterolaterally.
Fixation of extra-articular distal-third humeral shaft fractures through a posterior approach using orthogonal double plates applied medially and posterolaterally after fracture reduction. Both radial and ulnar nerves were identified and protected during the procedure.

Was misst die Studie?

Primäre Ergebnismessungen

Ergebnis Maßnahme
Maßnahmenbeschreibung
Zeitfenster
Mayo Elbow Performance Score (MEPS)
Zeitfenster: 24 months after surgery
pain (45 points), range of motion (20 points), stability (10 points), and daily functional tasks (25 points). Total maximum score is 100 meaning best outcome and total minimum score is 10 indicating worst outcome
24 months after surgery

Sekundäre Ergebnismessungen

Ergebnis Maßnahme
Zeitfenster
Betriebszeit
Zeitfenster: Intraoperativ
Intraoperativ
Fracture Union
Zeitfenster: Upto 24 months after surgery
Upto 24 months after surgery
Nerve injury complications
Zeitfenster: Immediately postoperative
Immediately postoperative

Mitarbeiter und Ermittler

Hier finden Sie Personen und Organisationen, die an dieser Studie beteiligt sind.

Studienaufzeichnungsdaten

Diese Daten verfolgen den Fortschritt der Übermittlung von Studienaufzeichnungen und zusammenfassenden Ergebnissen an ClinicalTrials.gov. Studienaufzeichnungen und gemeldete Ergebnisse werden von der National Library of Medicine (NLM) überprüft, um sicherzustellen, dass sie bestimmten Qualitätskontrollstandards entsprechen, bevor sie auf der öffentlichen Website veröffentlicht werden.

Haupttermine studieren

Studienbeginn (Tatsächlich)

1. Dezember 2025

Primärer Abschluss (Tatsächlich)

1. Juni 2026

Studienabschluss (Geschätzt)

1. Dezember 2026

Studienanmeldedaten

Zuerst eingereicht

9. Juni 2026

Zuerst eingereicht, das die QC-Kriterien erfüllt hat

11. Juni 2026

Zuerst gepostet (Tatsächlich)

12. Juni 2026

Studienaufzeichnungsaktualisierungen

Letztes Update gepostet (Tatsächlich)

12. Juni 2026

Letztes eingereichtes Update, das die QC-Kriterien erfüllt

11. Juni 2026

Zuletzt verifiziert

1. Juni 2026

Mehr Informationen

Begriffe im Zusammenhang mit dieser Studie

Andere Studien-ID-Nummern

  • N-275-2025

Plan für individuelle Teilnehmerdaten (IPD)

Planen Sie, individuelle Teilnehmerdaten (IPD) zu teilen?

NEIN

Arzneimittel- und Geräteinformationen, Studienunterlagen

Studiert ein von der US-amerikanischen FDA reguliertes Arzneimittelprodukt

Nein

Studiert ein von der US-amerikanischen FDA reguliertes Geräteprodukt

Nein

Diese Informationen wurden ohne Änderungen direkt von der Website clinicaltrials.gov abgerufen. Wenn Sie Ihre Studiendaten ändern, entfernen oder aktualisieren möchten, wenden Sie sich bitte an register@clinicaltrials.gov. Sobald eine Änderung auf clinicaltrials.gov implementiert wird, wird diese automatisch auch auf unserer Website aktualisiert .

Klinische Studien zur Humerusfraktur

Klinische Studien zur Reversed PHILOS Plate

Abonnieren