- ICH GCP
- Registro de ensayos clínicos de EE. UU.
- Ensayo clínico NCT07645768
Is Anterior Reversed Proximal Humeral Locking Plate System (PHILOS) a Safe Alternative to Conventional Posterior Double Plating in Extra-Articular Distal Shaft Humeral Fractures
Is Anterior Reversed Proximal Humeral Locking Plate System (PHILOS) a Safe Alternative to Conventional Posterior Double Plating in Extra-Articular Distal Shaft Humeral Fractures: A Randomized Controlled Trial
Extra-articular distal-third humeral shaft fractures are difficult to treat because stable fixation must be achieved while minimizing soft-tissue injury and the risk of nerve damage. Posterior double plating is a commonly used technique but requires extensive surgical exposure and routine handling of the radial and ulnar nerves. Anterior reversed proximal humeral locking plate system (PHILOS) fixation has emerged as a potential alternative that may provide adequate stability with less soft-tissue disruption.
This randomized controlled trial compares anterior reversed PHILOS plating with conventional posterior double plating in adult patients with extra-articular distal-third humeral shaft fractures. The study evaluates functional outcome using the Mayo Elbow Performance Score (MEPS) as primary outcome. Sexondary outcomes include: fracture union, operative parameters, range of motion, and complications including nerve injury, infection, and postoperative stiffness.
Descripción general del estudio
Estado
Condiciones
Intervención / Tratamiento
Tipo de estudio
Inscripción (Estimado)
Fase
- No aplica
Contactos y Ubicaciones
Ubicaciones de estudio
-
-
-
Cairo, Egipto
- Trauma and Orthopedic department, Faculty of Medicine, Cairo University
-
-
Criterios de participación
Criterio de elegibilidad
Edades elegibles para estudiar
- Adulto
- Adulto Mayor
Acepta Voluntarios Saludables
Descripción
Inclusion Criteria:
- Adults aged 18 years or older.
- Acute extra-articular distal humeral shaft fracture.
- AO/OTA type 12-A (simple) or 12-B (wedge) fracture.
- Closed fracture.
- Isolated injury.
- Presentation within 14 days of injury.
- Ability to provide informed consent and comply with follow-up.
Exclusion Criteria:
- Open fractures.
- Pathological fractures.
- Previous surgery on the ipsilateral humerus.
- Polytrauma requiring staged fixation.
- Contraindication to general anesthesia.
- Inability to complete the required follow-up period.
Plan de estudios
¿Cómo está diseñado el estudio?
Detalles de diseño
- Propósito principal: Tratamiento
- Asignación: Aleatorizado
- Modelo Intervencionista: Asignación paralela
- Enmascaramiento: Único
Armas e Intervenciones
Grupo de participantes/brazo |
Intervención / Tratamiento |
|---|---|
|
Experimental: Anterior Reversed PHILOS Plating
Patients with extra-articular distal-third humeral shaft fractures treated using an anterior approach and fixation with a reversed Proximal Humeral Internal Locking System (PHILOS) plate.
|
Fixation of extra-articular distal-third humeral shaft fractures using a reversed proximal humeral internal locking system (PHILOS) plate applied to the anterior surface of the humerus through an anterior approach.
The construct was secured with locking screws proximal and distal to the fracture site.
|
|
Experimental: Posterior Double Plating
Patients with extra-articular distal-third humeral shaft fractures treated using a posterior approach and fixation with orthogonal double plates applied medially and posterolaterally.
|
Fixation of extra-articular distal-third humeral shaft fractures through a posterior approach using orthogonal double plates applied medially and posterolaterally after fracture reduction.
Both radial and ulnar nerves were identified and protected during the procedure.
|
¿Qué mide el estudio?
Medidas de resultado primarias
Medida de resultado |
Medida Descripción |
Periodo de tiempo |
|---|---|---|
|
Mayo Elbow Performance Score (MEPS)
Periodo de tiempo: 24 months after surgery
|
pain (45 points), range of motion (20 points), stability (10 points), and daily functional tasks (25 points).
Total maximum score is 100 meaning best outcome and total minimum score is 10 indicating worst outcome
|
24 months after surgery
|
Medidas de resultado secundarias
Medida de resultado |
Periodo de tiempo |
|---|---|
|
Tiempo operatorio
Periodo de tiempo: Intraoperatorio
|
Intraoperatorio
|
|
Fracture Union
Periodo de tiempo: Upto 24 months after surgery
|
Upto 24 months after surgery
|
|
Nerve injury complications
Periodo de tiempo: Immediately postoperative
|
Immediately postoperative
|
Colaboradores e Investigadores
Patrocinador
Fechas de registro del estudio
Fechas importantes del estudio
Inicio del estudio (Actual)
Finalización primaria (Actual)
Finalización del estudio (Estimado)
Fechas de registro del estudio
Enviado por primera vez
Primero enviado que cumplió con los criterios de control de calidad
Publicado por primera vez (Actual)
Actualizaciones de registros de estudio
Última actualización publicada (Actual)
Última actualización enviada que cumplió con los criterios de control de calidad
Última verificación
Más información
Términos relacionados con este estudio
Términos MeSH relevantes adicionales
Otros números de identificación del estudio
- N-275-2025
Plan de datos de participantes individuales (IPD)
¿Planea compartir datos de participantes individuales (IPD)?
Información sobre medicamentos y dispositivos, documentos del estudio
Estudia un producto farmacéutico regulado por la FDA de EE. UU.
Estudia un producto de dispositivo regulado por la FDA de EE. UU.
Esta información se obtuvo directamente del sitio web clinicaltrials.gov sin cambios. Si tiene alguna solicitud para cambiar, eliminar o actualizar los detalles de su estudio, comuníquese con register@clinicaltrials.gov. Tan pronto como se implemente un cambio en clinicaltrials.gov, también se actualizará automáticamente en nuestro sitio web. .