Deze pagina is automatisch vertaald en de nauwkeurigheid van de vertaling kan niet worden gegarandeerd. Raadpleeg de Engelse versie voor een brontekst.

LMA Protector vs I-Gel in Low-Flow Anesthesia for Laparoscopic Cholecystectomy

11 juli 2026 bijgewerkt door: Ahmet Emre Akın, Fatih Sultan Mehmet Training and Research Hospital

Comparison of LMA Protector and I-Gel Use in Low-Flow Anesthesia for Laparoscopic Cholecystectomy: A Prospective Randomized Study

This prospective randomized study aims to compare two second-generation supraglottic airway devices (SGAs), the I-Gel and the laryngeal mask airway (LMA) Protector, in patients undergoing laparoscopic cholecystectomy under low-flow desflurane anesthesia. The study evaluates the devices in terms of respiratory mechanics (dynamic compliance, peak inspiratory pressure, plateau pressure, and airway resistance), non-invasive perfusion parameters (oxygen reserve index, perfusion index, and pleth variability index), hemodynamic stability, ease of insertion, oropharyngeal leak pressure, and postoperative complication rates.

Studie Overzicht

Gedetailleerde beschrijving

Sixty-two patients (ASA I-II, aged 18-65 years) scheduled for elective laparoscopic cholecystectomy were randomized into two groups: Group I (I-Gel) and Group P (LMA Protector). General anesthesia induction was standardized, and maintenance was provided with desflurane at a fresh gas flow of 1 L/min to achieve low-flow anesthesia. Peak inspiratory pressure (PIP), plateau pressure (Pplato), dynamic compliance (Cdyn), and airway resistance were recorded at six distinct intraoperative time points: 5 minutes after SGA insertion (T1), 1 minute after pneumoperitoneum insufflation (T2), 1 minute after the 30-degree reverse Trendelenburg position (T3), 10 minutes after insufflation (T4), 1 minute after desufflation (T5), and immediately before SGA removal (T6). Oropharyngeal leak pressure (OLP) was measured after insertion and before removal. Postoperative complications such as sore throat, cough, hoarseness, dysphagia, and nausea-vomiting were monitored postoperatively.

Studietype

Ingrijpend

Inschrijving (Werkelijk)

62

Fase

  • Niet toepasbaar

Contacten en locaties

In dit gedeelte vindt u de contactgegevens van degenen die het onderzoek uitvoeren en informatie over waar dit onderzoek wordt uitgevoerd.

Studie Locaties

      • Istanbul, Turkije (Türkiye), 34752
        • Fatih Sultan Mehmet Training and Research Hospital

Deelname Criteria

Onderzoekers zoeken naar mensen die aan een bepaalde beschrijving voldoen, de zogenaamde geschiktheidscriteria. Enkele voorbeelden van deze criteria zijn iemands algemene gezondheidstoestand of eerdere behandelingen.

Geschiktheidscriteria

Leeftijden die in aanmerking komen voor studie

  • Volwassen
  • Oudere volwassene

Accepteert gezonde vrijwilligers

Nee

Beschrijving

Inclusion Criteria:

  • Patients aged 18-65 years
  • American Society of Anesthesiologists (ASA) physical status I or II
  • Scheduled for elective laparoscopic cholecystectomy

Exclusion Criteria:

  • Known or predicted difficult airway or history of difficult intubation
  • Body Mass Index (BMI) greater than 35 kg/m²
  • High risk of gastroesophageal reflux or aspiration
  • Severe cardiac, respiratory, renal, or hepatic disease
  • Pregnancy
  • Patient refusal to participate

Studie plan

Dit gedeelte bevat details van het studieplan, inclusief hoe de studie is opgezet en wat de studie meet.

Hoe is de studie opgezet?

Ontwerpdetails

  • Primair doel: Behandeling
  • Toewijzing: Gerandomiseerd
  • Interventioneel model: Parallelle opdracht
  • Masker: Enkel

Wapens en interventies

Deelnemersgroep / Arm
Interventie / Behandeling
Experimenteel: Group I: I-Gel
Patients managed with the I-Gel supraglottic airway device during low-flow desflurane anesthesia for laparoscopic cholecystectomy.
Placement of an appropriate size of i-gel supraglottic airway device for airway management during general anesthesia. Anesthesia maintenance is provided with desflurane in a fresh gas flow of 1 L/min (low-flow anesthesia).
Andere namen:
  • i-gel
Experimenteel: Group P: LMA Protector
Patients managed with the LMA Protector supraglottic airway device during low-flow desflurane anesthesia for laparoscopic cholecystectomy.
Placement of an appropriate size of LMA Protector supraglottic airway device for airway management during general anesthesia. Anesthesia maintenance is provided with desflurane in a fresh gas flow of 1 L/min (low-flow anesthesia).
Andere namen:
  • Laryngeal Mask Airway Protector

Wat meet het onderzoek?

Primaire uitkomstmaten

Uitkomstmaat
Maatregel Beschrijving
Tijdsspanne
Dynamic Lung Compliance (Cdyn)
Tijdsspanne: Measured intraoperatively at 6 specific time points from 5 minutes after device insertion until immediately before device removal.
Dynamic compliance of the respiratory system, calculated automatically by the ventilator as tidal volume divided by (peak inspiratory pressure minus positive end-expiratory pressure).
Measured intraoperatively at 6 specific time points from 5 minutes after device insertion until immediately before device removal.

Secundaire uitkomstmaten

Uitkomstmaat
Maatregel Beschrijving
Tijdsspanne
Peak Inspiratory Pressure (PIP)
Tijdsspanne: Measured intraoperatively at 6 specific time points from 5 minutes after device insertion until immediately before device removal.
Maximum airway pressure generated during the inspiratory phase, monitored to assess airway dynamics under general anesthesia.
Measured intraoperatively at 6 specific time points from 5 minutes after device insertion until immediately before device removal.
Plateau Pressure (Pplateau)
Tijdsspanne: Measured intraoperatively at 6 specific time points from 5 minutes after device insertion until immediately before device removal.
Pressure applied to the small airways and alveoli during a period of zero gas flow, monitored to assess risk of barotrauma.
Measured intraoperatively at 6 specific time points from 5 minutes after device insertion until immediately before device removal.
Airway Resistance
Tijdsspanne: Measured intraoperatively at 6 specific time points from 5 minutes after device insertion until immediately before device removal.
The resistance of the respiratory tract to airflow during mechanical ventilation, calculated using peak and plateau pressures.
Measured intraoperatively at 6 specific time points from 5 minutes after device insertion until immediately before device removal.

Medewerkers en onderzoekers

Hier vindt u mensen en organisaties die betrokken zijn bij dit onderzoek.

Studie record data

Deze datums volgen de voortgang van het onderzoeksdossier en de samenvatting van de ingediende resultaten bij ClinicalTrials.gov. Studieverslagen en gerapporteerde resultaten worden beoordeeld door de National Library of Medicine (NLM) om er zeker van te zijn dat ze voldoen aan specifieke kwaliteitscontrolenormen voordat ze op de openbare website worden geplaatst.

Bestudeer belangrijke data

Studie start (Werkelijk)

1 juli 2020

Primaire voltooiing (Werkelijk)

31 oktober 2020

Studie voltooiing (Werkelijk)

31 oktober 2020

Studieregistratiedata

Eerst ingediend

5 juli 2026

Eerst ingediend dat voldeed aan de QC-criteria

11 juli 2026

Eerst geplaatst (Werkelijk)

16 juli 2026

Updates van studierecords

Laatste update geplaatst (Werkelijk)

16 juli 2026

Laatste update ingediend die voldeed aan QC-criteria

11 juli 2026

Laatst geverifieerd

1 juli 2026

Meer informatie

Termen gerelateerd aan deze studie

Plan Individuele Deelnemersgegevens (IPD)

Bent u van plan om gegevens van individuele deelnemers (IPD) te delen?

NEE

Informatie over medicijnen en apparaten, studiedocumenten

Bestudeert een door de Amerikaanse FDA gereguleerd geneesmiddel

Nee

Bestudeert een door de Amerikaanse FDA gereguleerd apparaatproduct

Nee

Deze informatie is zonder wijzigingen rechtstreeks van de website clinicaltrials.gov gehaald. Als u verzoeken heeft om uw onderzoeksgegevens te wijzigen, te verwijderen of bij te werken, neem dan contact op met register@clinicaltrials.gov. Zodra er een wijziging wordt doorgevoerd op clinicaltrials.gov, wordt deze ook automatisch bijgewerkt op onze website .