- ICH GCP
- US-Register für klinische Studien
- Klinische Studie NCT07707440
LMA Protector vs I-Gel in Low-Flow Anesthesia for Laparoscopic Cholecystectomy
11. Juli 2026 aktualisiert von: Ahmet Emre Akın, Fatih Sultan Mehmet Training and Research Hospital
Comparison of LMA Protector and I-Gel Use in Low-Flow Anesthesia for Laparoscopic Cholecystectomy: A Prospective Randomized Study
This prospective randomized study aims to compare two second-generation supraglottic airway devices (SGAs), the I-Gel and the laryngeal mask airway (LMA) Protector, in patients undergoing laparoscopic cholecystectomy under low-flow desflurane anesthesia.
The study evaluates the devices in terms of respiratory mechanics (dynamic compliance, peak inspiratory pressure, plateau pressure, and airway resistance), non-invasive perfusion parameters (oxygen reserve index, perfusion index, and pleth variability index), hemodynamic stability, ease of insertion, oropharyngeal leak pressure, and postoperative complication rates.
Studienübersicht
Status
Abgeschlossen
Intervention / Behandlung
Detaillierte Beschreibung
Sixty-two patients (ASA I-II, aged 18-65 years) scheduled for elective laparoscopic cholecystectomy were randomized into two groups: Group I (I-Gel) and Group P (LMA Protector).
General anesthesia induction was standardized, and maintenance was provided with desflurane at a fresh gas flow of 1 L/min to achieve low-flow anesthesia.
Peak inspiratory pressure (PIP), plateau pressure (Pplato), dynamic compliance (Cdyn), and airway resistance were recorded at six distinct intraoperative time points: 5 minutes after SGA insertion (T1), 1 minute after pneumoperitoneum insufflation (T2), 1 minute after the 30-degree reverse Trendelenburg position (T3), 10 minutes after insufflation (T4), 1 minute after desufflation (T5), and immediately before SGA removal (T6).
Oropharyngeal leak pressure (OLP) was measured after insertion and before removal.
Postoperative complications such as sore throat, cough, hoarseness, dysphagia, and nausea-vomiting were monitored postoperatively.
Studientyp
Interventionell
Einschreibung (Tatsächlich)
62
Phase
- Unzutreffend
Kontakte und Standorte
Dieser Abschnitt enthält die Kontaktdaten derjenigen, die die Studie durchführen, und Informationen darüber, wo diese Studie durchgeführt wird.
Studienorte
-
-
-
Istanbul, Türkei (türkiye), 34752
- Fatih Sultan Mehmet Training and Research Hospital
-
-
Teilnahmekriterien
Forscher suchen nach Personen, die einer bestimmten Beschreibung entsprechen, die als Auswahlkriterien bezeichnet werden. Einige Beispiele für diese Kriterien sind der allgemeine Gesundheitszustand einer Person oder frühere Behandlungen.
Zulassungskriterien
Studienberechtigtes Alter
- Erwachsene
- Älterer Erwachsener
Akzeptiert gesunde Freiwillige
Nein
Beschreibung
Inclusion Criteria:
- Patients aged 18-65 years
- American Society of Anesthesiologists (ASA) physical status I or II
- Scheduled for elective laparoscopic cholecystectomy
Exclusion Criteria:
- Known or predicted difficult airway or history of difficult intubation
- Body Mass Index (BMI) greater than 35 kg/m²
- High risk of gastroesophageal reflux or aspiration
- Severe cardiac, respiratory, renal, or hepatic disease
- Pregnancy
- Patient refusal to participate
Studienplan
Dieser Abschnitt enthält Einzelheiten zum Studienplan, einschließlich des Studiendesigns und der Messung der Studieninhalte.
Wie ist die Studie aufgebaut?
Designdetails
- Hauptzweck: Behandlung
- Zuteilung: Zufällig
- Interventionsmodell: Parallele Zuordnung
- Maskierung: Single
Waffen und Interventionen
Teilnehmergruppe / Arm |
Intervention / Behandlung |
|---|---|
|
Experimental: Group I: I-Gel
Patients managed with the I-Gel supraglottic airway device during low-flow desflurane anesthesia for laparoscopic cholecystectomy.
|
Placement of an appropriate size of i-gel supraglottic airway device for airway management during general anesthesia.
Anesthesia maintenance is provided with desflurane in a fresh gas flow of 1 L/min (low-flow anesthesia).
Andere Namen:
|
|
Experimental: Group P: LMA Protector
Patients managed with the LMA Protector supraglottic airway device during low-flow desflurane anesthesia for laparoscopic cholecystectomy.
|
Placement of an appropriate size of LMA Protector supraglottic airway device for airway management during general anesthesia.
Anesthesia maintenance is provided with desflurane in a fresh gas flow of 1 L/min (low-flow anesthesia).
Andere Namen:
|
Was misst die Studie?
Primäre Ergebnismessungen
Ergebnis Maßnahme |
Maßnahmenbeschreibung |
Zeitfenster |
|---|---|---|
|
Dynamic Lung Compliance (Cdyn)
Zeitfenster: Measured intraoperatively at 6 specific time points from 5 minutes after device insertion until immediately before device removal.
|
Dynamic compliance of the respiratory system, calculated automatically by the ventilator as tidal volume divided by (peak inspiratory pressure minus positive end-expiratory pressure).
|
Measured intraoperatively at 6 specific time points from 5 minutes after device insertion until immediately before device removal.
|
Sekundäre Ergebnismessungen
Ergebnis Maßnahme |
Maßnahmenbeschreibung |
Zeitfenster |
|---|---|---|
|
Peak Inspiratory Pressure (PIP)
Zeitfenster: Measured intraoperatively at 6 specific time points from 5 minutes after device insertion until immediately before device removal.
|
Maximum airway pressure generated during the inspiratory phase, monitored to assess airway dynamics under general anesthesia.
|
Measured intraoperatively at 6 specific time points from 5 minutes after device insertion until immediately before device removal.
|
|
Plateau Pressure (Pplateau)
Zeitfenster: Measured intraoperatively at 6 specific time points from 5 minutes after device insertion until immediately before device removal.
|
Pressure applied to the small airways and alveoli during a period of zero gas flow, monitored to assess risk of barotrauma.
|
Measured intraoperatively at 6 specific time points from 5 minutes after device insertion until immediately before device removal.
|
|
Airway Resistance
Zeitfenster: Measured intraoperatively at 6 specific time points from 5 minutes after device insertion until immediately before device removal.
|
The resistance of the respiratory tract to airflow during mechanical ventilation, calculated using peak and plateau pressures.
|
Measured intraoperatively at 6 specific time points from 5 minutes after device insertion until immediately before device removal.
|
Mitarbeiter und Ermittler
Hier finden Sie Personen und Organisationen, die an dieser Studie beteiligt sind.
Mitarbeiter
Studienaufzeichnungsdaten
Diese Daten verfolgen den Fortschritt der Übermittlung von Studienaufzeichnungen und zusammenfassenden Ergebnissen an ClinicalTrials.gov. Studienaufzeichnungen und gemeldete Ergebnisse werden von der National Library of Medicine (NLM) überprüft, um sicherzustellen, dass sie bestimmten Qualitätskontrollstandards entsprechen, bevor sie auf der öffentlichen Website veröffentlicht werden.
Haupttermine studieren
Studienbeginn (Tatsächlich)
1. Juli 2020
Primärer Abschluss (Tatsächlich)
31. Oktober 2020
Studienabschluss (Tatsächlich)
31. Oktober 2020
Studienanmeldedaten
Zuerst eingereicht
5. Juli 2026
Zuerst eingereicht, das die QC-Kriterien erfüllt hat
11. Juli 2026
Zuerst gepostet (Tatsächlich)
16. Juli 2026
Studienaufzeichnungsaktualisierungen
Letztes Update gepostet (Tatsächlich)
16. Juli 2026
Letztes eingereichtes Update, das die QC-Kriterien erfüllt
11. Juli 2026
Zuletzt verifiziert
1. Juli 2026
Mehr Informationen
Begriffe im Zusammenhang mit dieser Studie
Schlüsselwörter
Andere Studien-ID-Nummern
- FSM KAEK-2020/79
Plan für individuelle Teilnehmerdaten (IPD)
Planen Sie, individuelle Teilnehmerdaten (IPD) zu teilen?
NEIN
Arzneimittel- und Geräteinformationen, Studienunterlagen
Studiert ein von der US-amerikanischen FDA reguliertes Arzneimittelprodukt
Nein
Studiert ein von der US-amerikanischen FDA reguliertes Geräteprodukt
Nein
Diese Informationen wurden ohne Änderungen direkt von der Website clinicaltrials.gov abgerufen. Wenn Sie Ihre Studiendaten ändern, entfernen oder aktualisieren möchten, wenden Sie sich bitte an register@clinicaltrials.gov. Sobald eine Änderung auf clinicaltrials.gov implementiert wird, wird diese automatisch auch auf unserer Website aktualisiert .
Klinische Studien zur Anästhesie, allgemein
-
DLR German Aerospace CenterAbgeschlossenDie Auswirkungen des neuartigen Entlastungsgeräts „HEPHAISTOS“ auf Knochen, Muskeln und Gefäße (HEP)Muskel; Atrophie, GeneralDeutschland
Klinische Studien zur I-Gel supraglottic airway
-
Sultan Abdulhamid Han Training and Research Hospital...RekrutierungSupraglottische Atemwege für die Vollnarkose | Bewertung des Atemwegsmanagements | Kehlkopfmasken-Luftwege | Supraglottische AtemwegeTürkei (türkiye)
-
University of MalayaAbgeschlossenAllgemeine Anästhesie | Supraglottische Atemwege | Wahloperation | Oropharyngealer LeckdruckMalaysia
-
The University of Texas Health Science Center,...AbgeschlossenEndotracheale Intubation | Supraglottische AtemwegeVereinigte Staaten
-
Seoul National University HospitalAbgeschlossenEndotracheale IntubationKorea, Republik von
-
Dokuz Eylul UniversityAbgeschlossen
-
Schulthess KlinikMedical University InnsbruckAbgeschlossenMorbidität der Atemwege | Geräteinduzierte Verletzung | Komplikation der Geräteeinführung | Nekrose, DruckSchweiz, Österreich
-
Aga Khan UniversityAbgeschlossenTrainingsgruppe, Sensibilität | IgelPakistan
-
Cairo UniversityAbgeschlossen
-
Bnai Zion Medical CenterNoch keine Rekrutierung
-
Ankara Diskapi Training and Research HospitalAbgeschlossenEffektive Technik zur Platzierung der Atemwege der I-Gel-MaskeTruthahn