Esta página foi traduzida automaticamente e a precisão da tradução não é garantida. Por favor, consulte o versão em inglês para um texto fonte.

LMA Protector vs I-Gel in Low-Flow Anesthesia for Laparoscopic Cholecystectomy

11 de julho de 2026 atualizado por: Ahmet Emre Akın, Fatih Sultan Mehmet Training and Research Hospital

Comparison of LMA Protector and I-Gel Use in Low-Flow Anesthesia for Laparoscopic Cholecystectomy: A Prospective Randomized Study

This prospective randomized study aims to compare two second-generation supraglottic airway devices (SGAs), the I-Gel and the laryngeal mask airway (LMA) Protector, in patients undergoing laparoscopic cholecystectomy under low-flow desflurane anesthesia. The study evaluates the devices in terms of respiratory mechanics (dynamic compliance, peak inspiratory pressure, plateau pressure, and airway resistance), non-invasive perfusion parameters (oxygen reserve index, perfusion index, and pleth variability index), hemodynamic stability, ease of insertion, oropharyngeal leak pressure, and postoperative complication rates.

Visão geral do estudo

Descrição detalhada

Sixty-two patients (ASA I-II, aged 18-65 years) scheduled for elective laparoscopic cholecystectomy were randomized into two groups: Group I (I-Gel) and Group P (LMA Protector). General anesthesia induction was standardized, and maintenance was provided with desflurane at a fresh gas flow of 1 L/min to achieve low-flow anesthesia. Peak inspiratory pressure (PIP), plateau pressure (Pplato), dynamic compliance (Cdyn), and airway resistance were recorded at six distinct intraoperative time points: 5 minutes after SGA insertion (T1), 1 minute after pneumoperitoneum insufflation (T2), 1 minute after the 30-degree reverse Trendelenburg position (T3), 10 minutes after insufflation (T4), 1 minute after desufflation (T5), and immediately before SGA removal (T6). Oropharyngeal leak pressure (OLP) was measured after insertion and before removal. Postoperative complications such as sore throat, cough, hoarseness, dysphagia, and nausea-vomiting were monitored postoperatively.

Tipo de estudo

Intervencional

Inscrição (Real)

62

Estágio

  • Não aplicável

Contactos e Locais

Esta seção fornece os detalhes de contato para aqueles que conduzem o estudo e informações sobre onde este estudo está sendo realizado.

Locais de estudo

      • Istanbul, Turquia (Türkiye), 34752
        • Fatih Sultan Mehmet Training and Research Hospital

Critérios de participação

Os pesquisadores procuram pessoas que se encaixem em uma determinada descrição, chamada de critérios de elegibilidade. Alguns exemplos desses critérios são a condição geral de saúde de uma pessoa ou tratamentos anteriores.

Critérios de elegibilidade

Idades elegíveis para estudo

  • Adulto
  • Adulto mais velho

Aceita Voluntários Saudáveis

Não

Descrição

Inclusion Criteria:

  • Patients aged 18-65 years
  • American Society of Anesthesiologists (ASA) physical status I or II
  • Scheduled for elective laparoscopic cholecystectomy

Exclusion Criteria:

  • Known or predicted difficult airway or history of difficult intubation
  • Body Mass Index (BMI) greater than 35 kg/m²
  • High risk of gastroesophageal reflux or aspiration
  • Severe cardiac, respiratory, renal, or hepatic disease
  • Pregnancy
  • Patient refusal to participate

Plano de estudo

Esta seção fornece detalhes do plano de estudo, incluindo como o estudo é projetado e o que o estudo está medindo.

Como o estudo é projetado?

Detalhes do projeto

  • Finalidade Principal: Tratamento
  • Alocação: Randomizado
  • Modelo Intervencional: Atribuição Paralela
  • Mascaramento: Solteiro

Armas e Intervenções

Grupo de Participantes / Braço
Intervenção / Tratamento
Experimental: Group I: I-Gel
Patients managed with the I-Gel supraglottic airway device during low-flow desflurane anesthesia for laparoscopic cholecystectomy.
Placement of an appropriate size of i-gel supraglottic airway device for airway management during general anesthesia. Anesthesia maintenance is provided with desflurane in a fresh gas flow of 1 L/min (low-flow anesthesia).
Outros nomes:
  • i-gel
Experimental: Group P: LMA Protector
Patients managed with the LMA Protector supraglottic airway device during low-flow desflurane anesthesia for laparoscopic cholecystectomy.
Placement of an appropriate size of LMA Protector supraglottic airway device for airway management during general anesthesia. Anesthesia maintenance is provided with desflurane in a fresh gas flow of 1 L/min (low-flow anesthesia).
Outros nomes:
  • Laryngeal Mask Airway Protector

O que o estudo está medindo?

Medidas de resultados primários

Medida de resultado
Descrição da medida
Prazo
Dynamic Lung Compliance (Cdyn)
Prazo: Measured intraoperatively at 6 specific time points from 5 minutes after device insertion until immediately before device removal.
Dynamic compliance of the respiratory system, calculated automatically by the ventilator as tidal volume divided by (peak inspiratory pressure minus positive end-expiratory pressure).
Measured intraoperatively at 6 specific time points from 5 minutes after device insertion until immediately before device removal.

Medidas de resultados secundários

Medida de resultado
Descrição da medida
Prazo
Peak Inspiratory Pressure (PIP)
Prazo: Measured intraoperatively at 6 specific time points from 5 minutes after device insertion until immediately before device removal.
Maximum airway pressure generated during the inspiratory phase, monitored to assess airway dynamics under general anesthesia.
Measured intraoperatively at 6 specific time points from 5 minutes after device insertion until immediately before device removal.
Plateau Pressure (Pplateau)
Prazo: Measured intraoperatively at 6 specific time points from 5 minutes after device insertion until immediately before device removal.
Pressure applied to the small airways and alveoli during a period of zero gas flow, monitored to assess risk of barotrauma.
Measured intraoperatively at 6 specific time points from 5 minutes after device insertion until immediately before device removal.
Airway Resistance
Prazo: Measured intraoperatively at 6 specific time points from 5 minutes after device insertion until immediately before device removal.
The resistance of the respiratory tract to airflow during mechanical ventilation, calculated using peak and plateau pressures.
Measured intraoperatively at 6 specific time points from 5 minutes after device insertion until immediately before device removal.

Colaboradores e Investigadores

É aqui que você encontrará pessoas e organizações envolvidas com este estudo.

Datas de registro do estudo

Essas datas acompanham o progresso do registro do estudo e os envios de resumo dos resultados para ClinicalTrials.gov. Os registros do estudo e os resultados relatados são revisados ​​pela National Library of Medicine (NLM) para garantir que atendam aos padrões específicos de controle de qualidade antes de serem publicados no site público.

Datas Principais do Estudo

Início do estudo (Real)

1 de julho de 2020

Conclusão Primária (Real)

31 de outubro de 2020

Conclusão do estudo (Real)

31 de outubro de 2020

Datas de inscrição no estudo

Enviado pela primeira vez

5 de julho de 2026

Enviado pela primeira vez que atendeu aos critérios de CQ

11 de julho de 2026

Primeira postagem (Real)

16 de julho de 2026

Atualizações de registro de estudo

Última Atualização Postada (Real)

16 de julho de 2026

Última atualização enviada que atendeu aos critérios de controle de qualidade

11 de julho de 2026

Última verificação

1 de julho de 2026

Mais Informações

Termos relacionados a este estudo

Outros números de identificação do estudo

  • FSM KAEK-2020/79

Plano para dados de participantes individuais (IPD)

Planeja compartilhar dados de participantes individuais (IPD)?

NÃO

Informações sobre medicamentos e dispositivos, documentos de estudo

Estuda um medicamento regulamentado pela FDA dos EUA

Não

Estuda um produto de dispositivo regulamentado pela FDA dos EUA

Não

Essas informações foram obtidas diretamente do site clinicaltrials.gov sem nenhuma alteração. Se você tiver alguma solicitação para alterar, remover ou atualizar os detalhes do seu estudo, entre em contato com register@clinicaltrials.gov. Assim que uma alteração for implementada em clinicaltrials.gov, ela também será atualizada automaticamente em nosso site .

Se inscrever